1. Product Description
+ Shipboard Bus cable:
Type: Profibus-DP/Profibus-DP(IS)
Conduct: Solid bare copper wire
Insulation: Foamed PE
Filler PP
Overall screen: AL/Mylar + Tinned copper wire
braid coverage≥60%
Inner sheath: SHF1/SHF2/SHF-MUD
Armored (Optional) Galvanized steel wire braiding, coverage≥60%
or Tinned copper braiding, coverage≥60% Outer sheath (Optional) SHF1/SHF2/SHF-MUD/SHF-FI
+ Shipboard Bus cable:
Type: CANBus/CANBus(IS)
Conduct: Stranded tinned copper wire
Insulation: Foamed PE
Filler PP
Overall screen: AL/Mylar + Tinned copper wire braid coverage ≥80%
Inner sheath: SHF1/SHF2/SHF-MUD
Armored (Optional) Galvanized steel wire braiding, coverage≥60%
or Tinned copper braiding, coverage≥60%
Outer sheath (Optional) SHF1/SHF2/SHF-MUD/SHF-FI
Type: RS485/422/ RS485/422(IS) Conduct: Stranded tinned copper wire
Insulation: Foamed PE
Filler PP
Individual screen (Optional) AL/Mylar
Overall screen: Tinned copper braiding, coverage≥85%
Inner sheath: SHF1
Armored (Optional) Galvanized steel wire braiding, coverage≥60%
or Tinned copper braiding, coverage≥60%
Outer sheath (Optional) SHF1/SHF2/SHF-MUD
TYPE APPROVAL CERTIFICATE
NO. ELE587524WS/002
Enclosure - Page 2 of 4
+ Detail information for cables as follow:
TYPE APPROVAL CERTIFICATE
NO. ELE587524WS/002
Enclosure - Page 3 of 4
TYPE APPROVAL CERTIFICATE
NO. ELE587524WS/002
Enclosure - Page 4 of 4
+ Properties’ suffix:
SHF1: Low Smoke, Zero Halogen, Flame retardant
SHF2 : Low Smoke , Zero Halogen, Flame retardant, Oil resistance
SHF-FI : Low Smoke , Zero Halogen, Flame retardant, Fire-resistant
SHF-MUD : Low Smoke , Zero Halogen, Flame retardant, Mud resistance
IS Intrinsically Safe
+ Install at: -20℃ to 60℃
+ Operate at: -52℃ to 90℃
2. Test standards:
+ IEC 61158-2-2014; IEC 60092-360-2021; NEK606-2022; IEC 60331-23-1999; IEC 60332-3-22-2018;
IEC 60332-1-2-2015;IEC60754-1-2019; IEC60754-2-2019;IEC61034-2-2019;IEC 61034-2-2019;
IEC 60684-2-2011;UL 1581.
3. Reference Documents:
+ Specification of marine cables. Filed by RINA with drawing No. SHEL-22054.
+ Manufacturer information. Filed by RINA with drawing No.: SHEL-21693.
+ Test Report: “Shanghai national center of testing and inspection fpr electric cable and wire Co., Ltd” Report No.: CT24-00826-3Y1. Filed by RINA with drawing No. SHEL-21695.
+ Routine test Report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-21689.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-21691.
+ Declaration for the manufacturer address signed by our attending Surveyor. Filed by RINA with drawing No.: SHEL-21688.
4. Notes/Remarks:
+ Restricted breathing test for cables has completed according to IEC 60079-14: 2013.
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
5. Renewal/Revision
+ May 9, 2023: initial certification. Certificate No. ELE089923WS/002.
+ December 19, 2024: renewed without design change. New certificate No. ELE587524WS/002 revokes previous certificate.