Product description:
The VEGAPULS C 21/ C 22/ C 23 are radar level sensors for continuous level measuring.
Main characteristics:
Operating voltage: 12 ... 35 V DC (24 V DC nom.)
Output signal: two-wire 4…20mA /HART
Ambient temperature range: -40°C to 80°C
Degree of protection: IP66/68
Pre-Assembled cable length: max. up to 30 m
Certificates for use in hazardous areas*:
IECEx KIWA 19.0014X:
Type of protection: Ex ib mb, Ex ta, ta/tb, tb
IECEx KIWA 19.0015X:
Type of protection: Ex ia
Process characteristics:
Max. measuring range: C 21/ C 22 up to 15 m, C 23 up to 30 m
Max. accuracy: ±2 mm
Max. process pressure: -1...+3 bar
Process temp.: -40°C ... +80°C
Additional place of manufacturing:
VEGA Americas
3877 Mason Research Pkwy 45036
Mason, OH
United States of America
Documents:
VEGAZW-6-64985
Drawings: BB1505-3; BB1585-3; GE4055; GE4056; GE4063 LP1505-3; LP1585-3; SB1505-3; SB1585-3;
Test reports:
Hansecontrol Zertifizierungsgesellschaft mbH: - 2001-0061601R02A_EMC; 2001-0061601R03-EMC
Paconsult: - 20-12891A-BE-VEGAPULS (VEGA);
Remarks:
- The products fulfill EC-Code: 31/41.
- The EMC requirements for installation on the Bridge and Deck Zones will be fulfilled by the equipment.
- For Passenger Vessels, level switches are not to be installed on flammable fluid tanks where they require tank wall penetration below the tank top.
- The sensing device is to be fitted with a valve or arranged such that it may be isolated and removed without emptying the tank or without impairing the integrity of pressurized system.
- Each particular application and installation is to be specifically approved in conjunction with the relevant system and tank arrangements.
- Wireless data communication used for vessel services (such as essential services, category I/II/III systems, etc.) will be specially considered provided the use of the wireless data communication results in a improvement in the safety of the vessel, compared to wired data communications.
* For installation in hazardous areas the requirements of the applicable safety certificates are to be complied with.