System description
Low-location lighting (LLL) electrically powered based on a sequence of modules that are made of point light
sources made of PCB and polymeric PCB package, aluminium profile and polymeric coverage.
Each module contains a circuit with green high intensity LED, as shown on LLL Technical and Installation manual and Low Location lighting technical specification issued by Wartsila Apss S.R.L.
Components:SMART-3L-1-00
Voltage : 6÷30 Vdc, Maximum power consumption: 2,5 mA at 24Vdc
EXIT Module:SMART-3L-2-E-00
Voltage : 6÷30 Vdc, Maximum power consumption: 80,9 mA at 24Vdc
ARROW Module:SMART-3L-2-A-00
Voltage : 6÷30 Vdc, Maximum power consumption: 22,9 mA at 24Vdc
STEP Module:SMART-3L-2-S\E-00
Voltage : 6÷30 Vdc, Maximum power consumption: 21,4 mA at 24Vdc
Field of application
Low location lighting system for passenger ship in compliance with ISO 15370(2021).
Reference document
- Architectural Drawings, issued by Wartsila APSS S.R.L and approved by RINA with n° CSST 14509;
- LLL Technical and Installation Manual, issued by Wartsila APSS S.R.L and approved by RINA with n° CSST 14515;
- Low Location light technical specification, issued by Wartsila APSS S.R.L and approved by RINA with n° CSST 14516;
- Test report 16A232F, issued by Teslab on 28/11/2016 and filed by RINA with n° CSST 14513;
- Test report 1144-QL16-r01 ver.0, issued by Qualilab on 14/11/2016 and filed by RINA with n° CSST 14514.
- Report Reference n° 222022E
- Report Reference n° 224089ARemarks
The LLL system should function at all times for at least 60 min after its activation.
The system is to be capable of being manually activated by a single action from the continuously manned central control station.Spacing between the point sources shall be no greater than 200 mm.In all passenger cabins, a placard, also referred to as mimic sign, explaining the purpouse of the LLL system and the actions to be taken in case of reduced visibility due to smoke, shall be affixed to the inside of the cabin door. |
|