MED240422CS!002ENGD- -  -  N-  TUBIFLON,PTFE HOSES TX.T.8850.50.XXX AND HOSE ASSEMBLIES TX.M.8850.50.XXX,PTFE HOSES TX.T.8850.51.XXX AND HOSE ASSEMBLIES TX.M.8850.51.XXX,(NOMINAL DIAMETER FROM 10 MM. TO 75 MM.) -N- S- S- -21/07/2022- Marine Equipment- - SN- S- - N-  - 56,375B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità- MED240422CS/002- N-Jul 20, 202756375
 
Form
  Marine Equipment(TO)
Certification N. MED240422CS/002 - (ENG)
Certificate date 21/07/2022
Type Protezione antincendio
Product Materials other than steel for pipes conveying oil or fuel oil: (c) flexible pipes assemblies and compensators
Item Nº MED/3.15c

Model or Denomin.
Items
TUBIFLON,PTFE HOSES TX.T.8850.50.XXX AND HOSE ASSEMBLIES TX.M.8850.50.XXX,PTFE HOSES TX.T.8850.51.XXX AND HOSE ASSEMBLIES TX.M.8850.51.XXX,(NOMINAL DIAMETER FROM 10 MM. TO 75 MM.)
Applicant TUBIFLEX S.P.A.
Place of requester STRADA TORINO 25  %  10043 Orbassano (TO)  % ITALY
Tel. N.,Fax, Email 011-9033201, 011-9033214, ---
Directive (EU) 2021/1158
Standards EN ISO 15540, EN ISO 15541
Reference Documents Regulation II-2/4.2.2.5.1 of SOLAS 74 Convention, as amended
Request 14/04/2017
Expire date 20/07/2027
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Giovanni Carratino S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED240422CS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2021/1158.
MED Item Nº MED/3.15c
Description Materials other than steel for pipes conveying oil or fuel oil: (c) flexible pipes assemblies and compensators
Type TUBIFLON; PTFE HOSES TX.T.8850.50.XXX AND HOSE ASSEMBLIES TX.M.8850.50.XXX; PTFE HOSES TX.T.8850.51.XXX AND HOSE ASSEMBLIES TX.M.8850.51.XXX; (NOMINAL DIAMETER FROM 10 MM. TO 75 MM.)
Applicant TUBIFLEX S.P.A.
STRADA TORINO 25,10043 Orbassano (TO),ITALY
Testing standards EN ISO 15540, EN ISO 15541
Reference standards Regulation II-2/4.2.2.5.1 of SOLAS 74 Convention, as amended
Issued in Genoa on
This Certificate is valid until
July 21, 2022
July 20, 2027
This Certificate consists of this sheet plus an attachment

________________________________________
Giovanni Carratino
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED240422CS/002
Page 1 of 2

TECHNICAL DATA


Appearance: flexible hose covered with metallic braid, with metallic fittings at both ends.
Composition: Multilayer virgin PTFE core, reinforced with an anti-abrasion covering in fiberglass, and one high tensile stainless steel braid 1.4301 EN10088-3 (AISI 304).


REFERENCE DOCUMENTS

- TUBIFLEX catalogue
- LAPI test reports nos. 153.0IS0110/13, 154.0IS0110/13 and 155.0IS0110/13
- Type Approval Certificate no. MAC067013CS issued on 1 August 2013.

FIELD OF APPLICATIONS

Nominal diameters: from 10 mm (3/8”) to 75 mm (3”) .
Maximum working pressure: 20 bar (DN 75 – 3”) to 125 bar (DN 10 – 3/8”)


TEST CARRIED OUT

Tests carried out by LAPI Laboratorio Prevenzione Incendi SpA, Via della Quercia 11, 59100 Prato, Italy on 08/02/2013, as per test reports Nos. 153.0IS0110/13, 154.0IS0110/13 and 155.0IS0110/13 dated 11/02/2013.




ATTACHMENT TO
CERTIFICATE No. MED240422CS/002
Pages 2 of 2

The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Giovanni Carratino
**** NOTICE: This is NOT an official certificate ****