Product Description
The MAXI NG Series and 1200SL WS and 1500SL WS are intended for installation onboard ships and other marine installation for the incineration of oil residue (sludge) or solid waste. The system also enables solid waste to be added to the incinerator when operating in oil residue (sludge) mode after the incinerator has warmed up. The solid waste is then burned with the assistance from the oil residue (sludge) burner when the heat from burning solid waste is insufficient. There is an additional mode where oil residue (sludge) and bilge oil can be fed into the incinerator together. In this mode incineration begins with feeding of oil residue (sludge) until the incinerator has warmed up, then bilge oil feeding begins using a separate bilge injection burner. The feeding rate of the oil residue (sludge) and bilge oil is controlled based on temperature in the primary combustion chamber so that the maximum capacity is not exceed.
The incinerators consist of a primary combustion chamber, a secondary combustion chamber and an after-burning chamber for burning out uncombusted exhaust gases. The combustion chambers are equipped with diesel oil burners.
Solid waste is fed into the incinerator through a door system with interlocks. This enables the waste packages to be loaded through the outer door and fed into the incinerators through the inner door when the outer door is closed in cycles (i.e., continuous feeding).
Ash accumulates in the combustion chambers and may be removed from the incinerator periodically when the incinerator is cold through the ash door.
A flue gas fan is fitted in the exhaust duct or on the incinerator module to pull a negative pressure in the combustion chamber. Cooling air is pulled through a jacket around the incinerator from the compartment the incinerator is located.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 2 of 12 |
Application
Model(*) | NG25SL WS | NG50SL WS | NG100SL WS |
Type of solid waste loading | Continuous feed | Continuous feed | Continuous feed |
Calorific capacity kW (kcal/h) | 209 (180,000) | 372 (320,000) | 581 (500,000) |
Solid waste (kg/h) | 40 | 80 | 100 |
Oil residue (sludge) (kg/h) | 21 | 38 | 58 |
Oil residue (sludge) (kg/h) with bilge water (l/h) (**) | 27
75 bilge water | 48
144 bilge water | 76
175 bilge water |
Model(*) | NG150SL WS | 1200SL WS | 1500SL WS |
Type of solid waste loading | Continuous feed | Continuous feed | Continuous feed |
Calorific capacity kW (kcal/h) | 814 (700,000) | 1163 (1,000,000) | 1500 (1,290,000) |
Solid waste (kg/h) | 100 | 230 | 230 |
Oil residue (sludge) (kg/h) | 81 | 116 | 150 |
Oil residue (sludge) (kg/h) with bilge water (l/h) (**) | 106
188 bilge water | 151
288 bilge water | 195
300 bilge water |
(*) Model code SL means equipped for burning Solid waste and Oil Residue (sludge) and WS means equipped with a sluice that can be continuously load.
(**) Oil Content in bilge water is 0%.
Electrical and control components
The units are controlled through automation systems of a type tested and accepted by a nationally recognized testing agency, according to international standards. Critical components are listed in the table below:
Component Type | Component Name and Model (**) | Maker |
Programmable Logic Controller (PLC) | MICROLOGIX 1400 Series | Allen-Bradley |
| SIMATIC S7-1200 Series | Siemens |
Human Machine Interface (HMI) | PV Plus 700 Series | Allen-Bradley |
| Pro-face GP4401 Series | Schneider Electric |
Flame Detection Replay | HRE-4X | Hyundai Marine Machinery Co., Ltd. |
Flame detector | Flame detection photocell QRB Series | Siemens AG |
(** ) The system can be configured with either a Allen-Bradley PLC and HMI or a Siemens PLC and HMI.
Change to these components are to be approved by RINA. Documentation confirming the approval are to be kept together with the certificate, or the certificate is to be updated.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 3 of 12 |
The software and firmware editions are listed in the table below:
Component | Software/Firmware Edition | Date |
Allen-Bradley MICROLOGIX 1400 Series | Software : RS LOGIX 500V8.XX
Firmware : 1.X | 2016 |
Siemens SIMATIC S7-1200 | Software : TIA POTAL V13.XX
Firmware : 10.X | 2016 |
Allen-Bradley PV Plus 700 Series (HMI) | Software : FT VIEW STUDIO V7.XX
Firmware : 10.X | 2016 |
Schneider Electric Pro-face GP4401 Series (HMI) | Software : GP-Pro EX V4.XX
Firem 4.X | 2016 |
Changes in the software which can alter the performance of the systems is to be approved by RINA. Note that testing of the system with the revised software may be required. Documentation confirming the approval (and any testing) are to be kept together with the certificate, or the certificate is to be updated.
Basic of acceptance
Capacity and emissions testing according to IMO Res.MEPC.244(66) Annex I were carried out on the MAXI NG50SL WS, MAXI NG100SL WS, MAXI NG150SL WS, MAXI 1200SL WS and MAXI 1500SL WS models and the results are given in the Appendices to this certificate.
Electrical and mechanical control devices have been assessed according to IMO Res.MEPC.244(66) 3.14.1.7 based on certificate according to internal standards accepted by a national recognized testing agency. The control pannels for the MAXI NG50SL WS, MAXI NG100SL WS, MAXI NG150SL WS, MAXI 1200SL WS and MAXI 1500SL WS models were each subjected to a function test between 2004 and 2006 and the final test reports are listed in the "Test Reports" section of this certificate. The control system was changed from a relay type to a PLC type in 2008 and so a new function test on a MAXI NG50SL WS was conducted. The test report is listed in the "Test Reports" section of this certificate. The MAXI NG Series, MAXI 1200SL WS and MAXI 1500SL WS use the same control system and so the test can be considered applicable to all models.
Inclination requirements according to IMO Res.MEPC.244(66) Section 6.2 were assessed during the testing of the MAXI NG50SL WS, MAXI NG150SL WS, MAXI 1200SL WS and MAXI 1500SL WS models.
Prototype tests according to IMO Res.MEPC.244(66) Section 7.1 were carried out on the MAXI NG50SL WS model and the final report is listed in the "Test Reports" section of this certificate. This test can be considered applicable to all models.
The series of incinerators with capacities from 256 kW to 1500 kW use the same basic design. Therefore, testing on the MAXI NG50SL WS, MAXI NG100SL WS, MAXI NG150SL WS, MAXI 1200SL WS and MAXI 1500SL WS is considered sufficient to cover all models.
The testing described above for solid waste and for oil residue (sludge) on the MAXI 1200SL WS was done under the authority of Bureau Veritas who issued EU MED Module B certificate no's 13837/C0 EC, 14517/B3 EC and 17450/B1 EC. The testing described above for oil residue (sludge) for the other models was done under the authority of Korean Register on behalf of the Republic of Korea.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 4 of 12 |
Technical Documentation
- Technical drawings and Manual, filed by RINA approved drawing no.PUMC-27805, 27807& 27811 as outlined below.
Drawing no. | Revision | Date | Description/name | Model |
VHS-NG0025SL WS-1 ~ 3 | R0 | 2016.04.12 | Main specification | MAXI NG25SL WS |
VHS-NG0050SL WS-1 ~ 3 | R0 | 2016.04.12 | Main specification | MAXI NG50SL WS |
VHS-NG0100SL WS-1 ~ 3 | R0 | 2016.04.12 | Main specification | MAXI NG100SL WS |
VHS-NG0150SL WS-1 ~ 3 | R0 | 2016.04.12 | Main specification | MAXI NG150SL WS |
VHS-1200SL WS-1 ~ 3 | R0 | 2016.04.12 | Main specification | MAXI 1200SL WS |
VHS-1500SL WS-1 ~ 3 | R0 | 2016.04.12 | Main specification | MAXI 1500SL WS |
VHS-LOCSA-STD-1 | R0 | 2016.04.12 | List of control /Safety / Automation | All Model |
VHS-PROCEDIA-STD-1 | R0 | 2016.04.12 | Process diagram incinerator | All Model |
HIE-P02020020 | R2 | 2016.03.24 | Piping diagram | MAXI NG25SL WS |
HMM-NINC202N-01 | R2 | 2016.03.24 | Outline dimension drawing | MAXI NG25SL WS |
HID-BOD020201 | R7 | 2013.04.30 | Assembly drawing of Basis part | MAXI NG25SL WS |
HMW-0253010 ~ 14 | R1 | 2013.04.30 | Assembly drawing of Refractory Lining | MAXI NG25SL WS |
HIE-P0402022 | R2 | 2016.03.24 | Piping diagram | MAXI NG50SL WS |
HMM-NINC402-01 | R2 | 2016.03.24 | Outline dimension drawing | MAXI NG50SL WS |
HID-BOD040203 | R5 | 2013.04.30 | Assembly drawing of Basis part | MAXI NG50SL WS |
HMW-0253010 ~ 14 | R1 | 2013.04.30 | Assembly drawing of Refractory Lining | MAXI NG50SL WS |
HIE-P06020022 | R2 | 2016.03.24 | Piping diagram | MAXI NG100SL WS |
HMM-NINC602-01 | R2 | 2016.03.24 | Outline dimension drawing | MAXI NG100SL WS |
HID-BOD060203 | R5 | 2013.04.30 | Assembly drawing of Basis part | MAXI NG100SL WS |
HMW-1002010 ~ 14 | R1 | 2013.04.30 | Assembly drawing of Refractory Lining | MAXI NG100SL WS |
HIE-P08020022 | R2 | 2016.03.24 | Piping diagram | MAXI NG150SL WS |
HMM-NINC802-01 | R2 | 2016.03.24 | Outline dimension drawing | MAXI NG150SL WS |
HID-BOD080203 | R4 | 22013.04.30 | Assembly drawing of Basis part | MAXI NG150SL WS |
HMW-1502010 ~ 14 | R1 | 2013.04.30. | Assembly drawing of Refractory Lining | MAXI NG150SL WS |
HIE-P12020022 | R2 | 2016.03.24 | Piping diagram | MAXI 1200SL WS |
HMM-NINC1204-01 | R2 | 2016.03.24 | Outline dimension drawing | MAXI 1200SL WS |
HID-BOD120203 | R4 | 2013.04.30 | Assembly drawing of Basis part | MAXI 1200SL WS |
HMW-12005010 ~ 14 | R1 | 2013.04.30 | Assembly drawing of Refractory Lining | MAXI 1200SL WS |
HIE-P15020022 | R2 | 2016.03.24 | Piping diagram | MAXI 1500SL WS |
HMM-NINC1502-01 | R2 | 2016.03.24 | Outline dimension drawing | MAXI 1500SL WS |
HID-BOD150203 | R4 | 2013.04.30 | Assembly drawing of Basis part | MAXI 1500SL WS |
HMW-1505010 ~ 14 | R1 | 2013.04.30 | Assembly drawing of Refractory Lining | MAXI 1500SL WS |
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 5 of 12 |
Drawing no. | Revision | Date | Description/name | Model |
HID-VM1502210 | R0 | 2013.04.30 | Detail drawing of Cleaning cover | All Model |
HID-VM202010 | R1 | 2013.04.30 | Detail drawing of Cleaning cover | MAXI NG25SL WS |
HID-S15002010 | R1 | 2013.04.30 | Assembly drawing of Waste sluice | MAXI 1500SL WS |
HID-S12002010 | R1 | 2013.04.30 | Assembly drawing of Waste sluice | All Model |
AT-ABB020010 | R0 | 2008.01.01 | Outline of primary blower | MAXI NG25SL WS |
AT-ABB040010 | R1 | 2008.01.01 | Outline of primary blower | MAXI NG50SL WS |
AT-ABB060010 | R1 | 2008.01.01 | Outline of primary blower | MAXI NG100SL WS |
AT-ABB080010 | R1 | 2008.01.01 | Outline of primary blower | MAXI NG150SL WS |
AT-ABB120010 | R1 | 2008.01.01 | Outline of primary blower | MAXI 1200SL WS |
AT-ABB150010 | R1 | 2008.01.01 | Outline of primary blower | MAXI 1500SL WS |
HIF-NGTSTD002 ~ 4 | R2 | 2016.03.24 | ELECTRIC PANEL-LAYOUT/FRONT | All Model |
HIF-NGTSTD005 ~ 7 | R2 | 2016.03.24 | ELECTRIC PANEL-LAYOUT/FRONT | All Model |
HIF-NGTSTD008 | R2 | 2016.03.24 | ELECTRIC PANEL-CONTROL SOURCE | All Model |
HIF-NGTSTD015 ~ 24 | R2 | 2016.03.24 | ELECTRIC PANEL-CIRCUIT DIAGRAM | All Model |
HIF-NGTSTD025 | R2 | 2016.03.24 | ELECTRIC PANEL-CIRCUIT OPTION | All Model |
HIF-NGTSTD030 | R2 | 2016.03.24 | ELECTRIC PANEL-EXTERNAL SIGNAL | All Model |
HIF-NGTSTD040 ~ 43 | R2 | 2016.03.24 | ELECTRIC PANEL-PART LIST | All Model |
HIF-NGTSTD501 ~ 3 | R2 | 2016.03.24 | ELECTRIC PANEL-TERMINAL STRIP | All Model |
HNP-MAXINC-EPA7 | R7 | 2011.11.26 | MAIN NAME PLATE | All Model |
NP-SIMENS-OPAPLC-NGT | R7 | 2014.09.11 | OPERATION INSTRUCTION PLATE | All Model |
NP-WNPLC | R9 | 2014.09.11 | WARNING PLATE | All Model |
HINC-PGM-MAXIJAL | R0 | 2015.09.11 | PLC LADDER SYSTEM SOFTWARE QUALITY PLAN | All Model |
V13-NGDO(PLC_SIMENS) | R13 | 2015.06.03 | INSTRUCTION MANUAL (NG25 ~ NG150) | All Model |
V13-BIG(PLC_SIMENS) | R13 | 2015.06.03 | INSTRUCTION MANUAL (MAXI 1200, 1500) | All Model |
V13-TDO(PLC_SIMENS) | R13 | 2015.06.03 | V13-TDO(PLC_SIMENS) | All Model |
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 6 of 12 |
Test Reports
Capacity and Emission tests, and safety and control tests:
- Type approval test procedure & report for waste oil incinerator, MAXI NG50SL WS, Hyundai Marine Machinery Co., Ltd., report HTTR-HM2404787 dated 31 March 2004. (Witnessed by Bureau Veritas)
- Type approval test procedure & report for waste oil incinerator, MAXI NG150SL WS, Hyundai Marine Machinery Co., Ltd., report HTTR-HM2401750 dated 5 March 2004. (Witnessed by Bureau Veritas)
- MAXI type W.O. incinerator test report, MAXI NG100SL WS, Hyundai Marine Machinery Co., Ltd., report HFTR-IMONG100 dated 13 Februray 2004. (Witnessed by Korean Register on behalf of the Republic of Korea.)
- MAXI type W.O. incinerator test report, MAXI NG150SL WS, Hyundai Marine Machinery Co., Ltd., report HFTR-IMONG150 dated 13 Februray 2004. (Witnessed by Korean Register on behalf of the Republic of Korea.)
- Type approval test procedure & report for waste oil incinerator, 1200S WS, Hyundai Marine Machinery Co., Ltd., report HTTR-HM2401748 dated 5 March 2004. (Witnessed by Bureau Veritas)
- Type approval sampling test report for waste oil incinerator, MAXI 1200SL WS, Hyundai Marine Machinery Co., Ltd., report HFT-MEDM1200SLWS dated 14 June 2006. (Witnessed by Bureau Veritas)
- Type approval test procedure & report for waste oil incinerator, MAXI 1500SL WS, Hyundai Marine Machinery Co., Ltd., report HTTR-2411896 dated 23 March 2005. (Witnessed by Bureau Veritas)
- Test reports, filed by RINA approved drawing no.PUMC-27806.
Safety and control tests (prototype tests according to IMO Res.MEPC.244(66) Section 7.1):
- Modification type approval test report for shipboard incinerator, MAXI NG50SL WS, Hyundai Marine Machinery Co., Ltd., report HTTR-SK111 dated 27 May 2008. (Witnessed by Bureau Veritas)
Marking of product
For traceability to this type approval, each incinerator is to be marked with:
- Manufacturer's name or trade mark
- Style, type, model or other manufacturer's designation for the incinerator (i.e., model name with serial number)
- Capacity (net design heat release)
Note
This certificate annuls and replaces the certificate No. MED247125PU dated 31-03-2026 due to change of the applicant's address.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 7 of 12 |
Appendix - Tests on MAXI NG50SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI NG50SL WS |
Place and date of tests | Seoul, 31 March 2004. (Witnessed by Bureau Veritas) |
Max. capacity | 271 kW (with Solid Waste) |
Solid Waste | 82.8 kg/h IMO Class 2
11,806 KJ/kg |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste |
O2 average in combustion chamber / zone | 11.5 % |
CO average in flue gas | 24.0 mg/MJ |
Soot number average | Bacharach 1 |
Combustion chamber flue gas outlet temperature average | 950 °C |
Amount of unburned components in ashes | 8.0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste |
Temperature | 326 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 8 of 12 |
Appendix - Tests on MAXI NG100SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI NG100SL WS |
Place and date of tests | Seoul, 13 February 2004. (Witnessed by Korean Register on behalf of the Republic of Korea) |
Max. capacity | 610 kW (with Solid Waste) |
Oil Residue (sludge) | 70.8 l/h
31,310 KJ/kg (29% water content) |
Pilot Fuel Consumption (Oil Residue (sludge)) | 0 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Oil Residue (sludge) |
O2 average in combustion chamber / zone | 8.1 % |
CO average in flue gas | 13.8 mg/MJ |
Soot number average | Bacharach 1 |
Combustion chamber flue gas outlet temperature average | 950 °C |
Amount of unburned components in ashes | 0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Oil Residue (sludge) |
Temperature | 320 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 9 of 12 |
Appendix - Tests on MAXI NG150SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI NG150SL WS |
Place and date of tests | Seoul, 5 March 2004. (solid waste, witnessed by Bureau Veritas)
Seoul, 13 February 2004 (oil residue, witnessed by Korean Register on behalf of the Republic of Korea) |
Max. capacity | 962 kW (with Oil Residue (sludge))
340 kW (with Solid Waste) |
Oil Residue (sludge) | 111.7 l/h
31,310 KJ/kg (29% water content) |
Solid Waste | 103.8 kg/h IMO Class 2
11,776 KJ/kg |
Pilot Fuel Consumption (Oil Residue (sludge)) | 0 kg/h per burner |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste | Oil Residue (sludge) |
O2 average in combustion chamber / zone | 10.6 % | 11.1 % |
CO average in flue gas | 7.0 mg/MJ | 7.0 mg/MJ |
Soot number average | Bacharach 1 | Bacharach 1 |
Combustion chamber flue gas outlet temperature average | 950 °C | 950 °C |
Amount of unburned components in ashes | 7.0 % | 0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste | Oil Residue (sludge) |
Temperature | 315 °C | 319 °C |
Distance | 2.5 m | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 10 of 12 |
Appendix - Tests on MAXI 1200SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI 1200S WS equivalent to a MAXI 1200SL WS (Solid Waste)
MAXI 1200SL WS (Oil Residue (sludge)) |
Place and date of tests | Seoul, 5 March 2004 (solid waste, witnessed by Bureau Veritas)
Seoul, 14 June 2006 (oil residue, witnessed by Bureau Veritas) |
Max. capacity | 1233 kW (with Oil Residue (sludge))
780 kW (with Solid Waste) |
Oil Residue (sludge) | 147.0 l/h
32,150 KJ/kg (26% water content) |
Solid Waste | 238.0 kg/h IMO Class 2
11,805 KJ/kg |
Pilot Fuel Consumption (Oil Residue (sludge)) | 0 kg/h per burner |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste | Oil Residue (sludge) |
O2 average in combustion chamber / zone | 11.2 % | 10.5 % |
CO average in flue gas | 61.7 mg/MJ | 7.6 mg/MJ |
Soot number average | Bacharach 2.5 | Bacharach 0 |
Combustion chamber flue gas outlet temperature average | 950 °C | 952 °C |
Amount of unburned components in ashes | 8.0 % | 0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste | Oil Residue (sludge) |
Temperature | 305 °C | 300 °C |
Distance | 2.5 m | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193726PU
Page 11 of 12 |
Appendix - Tests on MAXI 1500SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI 1500SL WS |
Place and date of tests | Seoul, 23 March 2005. (Witnessed by Bureau Veritas) |
Max. capacity | 781 kW (with Solid Waste) |
Solid Waste | 238.0 kg/h IMO Class 2
11,805 KJ/kg |
Pilot Fuel Consumption (Solid Waste) | 32 kg/h per primary burner
27 kg/h secondary burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste |
O2 average in combustion chamber / zone | 11.1 % |
CO average in flue gas | 2.3 mg/MJ |
Soot number average | Bacharach 0 |
Combustion chamber flue gas outlet temperature average | 950 °C |
Amount of unburned components in ashes | 8.0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste |
Temperature | 311 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.