Product description
Pilot ladder with the following main components:
Hardwood: Lenght: 525 mm - Breadth: 115 mm - Height : 28 mm, 4 holes Ø 24 mm;
Hardwood Spreader step: Lenght: 1800 mm - Breadth: 115 mm - Height: 28 mm, 4 holes Ø 24 mm;
Rubber step: Lenght: 525 mm - Breadth: 115 mm - Height : 28 mm, 4 holes Ø 24 mm;
Manila rope Diameter 22 mm - Minimum breaking strenghth: 24 kN.
Spacing between steps: 330 ± 20 mm
Spacing between side ropes: ≥ 400 mm
Maximum length of ladder: 25 m
Operation and storage temperature: -30 to +65
Reference documents
Maintanance and Use Instruction HE-TD-030/7M/11/PL Rev. 1 dated 15 Jul 2025 issued by Harbour Enterprise Ltd,, filed by RINA with Ref. PLFP/3267
Pilot Ladder Requirements Maintanance and Instruction HE-TD-030/7M/11/PL Annex Rev. 1 dated 15 Jul 2025 issued by Harbour Enterprise Ltd,, filed by RINA with Ref. PLFP/3266
General arrangement and components filed by RINA with Ref. PLFP/3258-PLFP/3263, PLFP/3265
Tests
Test Report for Pilot Ladder dated 26 Aug 2025 witnessed by RINA Survey, filed by RINA under Ref. PLFP/3250
Test Report for Rope No LX20250707007 dated 11 July 2025 issued by Lianxin Testing (Jiangsu) Co. Ltd., filed by RINA under Ref. PLFP/3275
Remarks
A ladder shall not include more than two replacement steps and one replacement spreader step. If a ladder requires third replacement step or a second replacement spreader step, it shall be rebuild.
Each ladder shall be subjected to the ladder and step attachment strength test in Table 2 of ISO 799:2019 at approximately 30 month intervals. Each ladder which fails the test shall be rebuilt or scrapped.
The bottom of the top step and the bottom of the lowest spreader step of the ladder shall be marked as per ISO 799-1:2019 Par 8.1.
The bottom of each replacement step shall be marked as per ISO 799-1:2019 Par 8.2
A permanent marking should be provided at regular intervals (e.g. 1 m) throughout the length of the ladder consistent with ladder design, use and maintenance in order to facilitate the rigging of the ladder to the required height.