Metallic pipe transits composed of a CuNi or stainless steel body hexagonal or octagonal shaped, fitted with a threaded coaming passing through the bulkhead plate. On the other side a CuNi or stainless steel body, hexagonal or octagonal shaped, is screwed to the coaming. The two bodies are fitted, inside, with graphite gaskets. The pipes are butt welded to the coaming on both sides or are fitted through the coaming and fillet welded to the same on both sides. The penetrations are insulated on both sides by means of mineral wool (certified non combustible in conformity to the requirements of the IMO FTP Code) having thickness of 30 mm and density of 36 kg/m3 or thickness of 70 mm and density of 56 kg/m3 whereas the pipes are insulated by means of mineral wool cylinders having thickness of 50 mm and density of 62 kg/m3.
The product may also be produced by:
- Chibro S.r.l. - Via Valtellina 15, Montano Lucino (CO) - Italy
- Rubinetterie Bresciane Bonomi S.p.A. - Via Circonvallazione 7, Bordolano (CR) - Italy
Reference documents
Rubinetterie Bresciane drawings No. R1513A-SKE005 Rev. B dated 12 December 2017, No. R1809A-ASS001 dated 1 February 2018 and No. R1809A-ASS010 dated 1 February 2018 approved on 16 January 2018 and on 13 February 2018 respectively with endorsement Nos. LABS-1594, LABS-1606 and LABS-1607.
Tests carried out
Tests as per RINA Test Laboratory Report No. 2017CS01973/1 issued on 16 January 2018 according to Appendix 1 of IMO 2010 FTPC Part 3 - A.III Pipe and Duct Penetrations.
|
ATTACHMENT TO
CERTIFICATE Nr. MED153525CS/001
Page 2 of 3 |
Field of application Fire resistant metallic pipe penetrations through steel bulkheads as per following tables:
A-60 CLASS
Transit dimensions (mm) | Pipe diameter (mm) | Coaming thickness (mm) | Insulation
(mineral wool) |
76 | 15 | 1.4 (4.1 in case of pipe fitted through the coaming) | One layer having density of 56 kg/m3, 220x220 mm; on the pipe a cylinder having density of 62 kg/m3 and length of 260 mm |
greater than 76 up to 180 | greater than 15 up to108 | 4.1 | One layer having density of 56 kg/m3, 320x320 mm; on the pipe a cylinder having density of 62 kg/m3 and length of 260 mm |
A-30 CLASS
Transit dimensions (mm) | Pipe diameter (mm) | Coaming thickness (mm) | Insulation
(mineral wool) |
76 | 15 | 1.4 (4.1 in case of pipe fitted through the coaming) | Two layers having density of 36 kg/m3, 200x200 mm; on the pipe a cylinder having density of 62 kg/m3, and length of 200 mm |
greater than 76 up to 180 | greater than 15 up to108 | 4.1 | Two layers having density of 36 kg/m3, 320x320 mm; on the pipe a cylinder having density of 62 kg/m3, and length of 200 mm |
A-0 CLASS
Transit dimensions (mm) | Pipe diameter (mm) | Coaming thickness (mm) | Insulation |
76 | 15 | 1.4 (4.1 in case of pipe fitted through the coaming) | - |
greater than 76 up to 180 | greater than 15 up to108 | 4.1 | - |
|