Intended Service
Human Interface for control, monitoring and alarm system. The modules are designed for marine ship applications, including bridge and engine monitoring.
Description
Display Module
Module Type
Name: SaCoS Display Module L S5k (DML S5k_2.0 & DML S5k_2.0_A)
Module class: 24 V electronic module for on engine application with SELV/PLEV voltage (Ue > 60 V DC)
Firmware version: DGM_PCC.img - Build date: 2021-06-29
Ratings
Power supply: 24 V DC
Ambient temperature: -10°C to 70°C
Class of protection: IP65
Vibration: +/- 1.6 mm / 4g
EMC: All locations.
Reference Documents:
- SaCoS 5000 Common Hardware - Product Specification, dated 06.10.2021
- SaCoS 5000 Product Spec. for DML S5k_2.x, DML S5k_2.x_A, GCM S5k_2.x, GCM S5k_2.x_A, dated 11.09.21
- SaCoS 5000 Brain Slug Board – BSB - Product Specification, dated 06.07.2021
- SaCoS Display Module L 2.x (DML 2.x) – Master Document for Type Approval, dated 11.11.2021
- SaCoS Modules – Test Specification for Type Approval, dated 09.2021
- EMC Compliance Report, DML S5k_2.0 (R2700102978), MAN-21002-PR01-E01-01, dated 05.11.2021
- Climatic Test Report, DML S5k_2.0 (R2700102978), CLI+MAN-21002-PR01-K01, dated 28.10.2021
- Mechanical Test Report, DML S5k_2.0 (R2700102978), MEC+MAN-21002-PR01-M01, dated 27.10.2021
- Test Report No. TR-713233335-01, Degree of Protection - IP65, dated 25.01.2022
Remarks:
The acceptance on board for each installation is subordinated to the submission to the approval of the following documentation:
- Reference to this and other Type Approval Certificate.
- System Block Diagram and SaCoS Hardware Configuration for the specific Diesel Engine / Ship propulsion
plant
- Dedicated FMEA and on board test schedule including the List for inspection of the alarm, safety and injection
control systems, in order to verify the compliance with SOLAS requirement Chapter II-1 - Rule 49
- Software version is to be available
CERTIFICATE RETENTION:
All changes in software and hardware are to be recorded as long as the system is in use on board.
The records of all changes are to be forwarded to RINA for evaluation and approval.
Major changes in the software / firmware are to be approved before being installed on the programmed systems. |
|