Double leaf hinged door whose maximum clear opening size is 2400 mm wide and 2200 mm high. The primary leaf has maximum width of 1621 mm and maximum height of 2217 mm; the secondary leaf has maximum width of 821 mm and maximum height of 2217 mm. The door leaves, having thickness of 50 mm, are composed of two carbon steel sheets, 1.2 mm thick each and, in between the insulating material compound. This compound is composed, moving from the hinged side, of a mineral wool layer type SEAROX SL 970, having thickness of 35 mm and density of 115 kg/m3, and a layer of material named PROMAGLAF GM, 12.6 mm thick and having density of 165 kg/m3. The insulating materials are glued together and to the steel sheets by means of 250 g/m2 of adhesive type DUNAPOL AD1670. The primary leaf is fitted, in the middle, with two C shaped steel stiffeners, 1.2 mm thick and having dimensions of 60x15 mm welded, symmetrically to the two steel sheets, on the upper and lower part of the leaf. The secondary leaf is equipped with a lever closing device, which acts on two points, fitted inside the leaf and actuated by an handle. The primary leaf is fitted with a lever closing device, which acts on three points, fitted inside the leaf and actuated by an handle. The door frame is composed of an S shaped steel profile having thickness of 5 mm, welded or bolted to the bulkhead by means of M8 bolts. The door may be fitted with a self-closing hose port having maximum dimensions of 188x160 mm.
Field of application Fire resistant A-30 Class single leaf hinged door in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and with of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf
- maximum door size tested
- door used with a fire tested frame design
Reference documents Naval Suppliers drawing No. FT_PA6ZI_242215_ASM-RZ1 dated 10 January 2018 approved with endorsement No. LABS-1615 on 8 March 2018.
Tests carried out Test as per RINA Test Laboratory report No. 2017CS012892/6 issued on 8 March 2018 according to IMO 2010 FTP CODE Part 3. |