1. Product Description:
+ HT series self-regulating trace heating cable with type as follow:
| Type | Rated Voltage | Output Power
at 10°C 220V | Ex-proof marking | Maximum maintenance temperature | Remark |
3HTLe | 110~120VAC
or
220~240VAC | 3W/ft | Ex eb ⅡC T6 Gb, Ex tb ⅢC T85°C Db | 65°C | Low temperature |
5HTLe | 5W/ft |
6HTLe | 6W/ft |
8HTLe | 8W/ft |
10HTLe | 10W/ft |
3HTR | 3W/ft | Ex eb ⅡC T6/T5 Gb,
Ex tb ⅢC T85°C/100°C Db | 65°C | Low temperature |
5HTR | 5W/ft |
6HTR | 6W/ft |
8HTR | 8W/ft |
10HTR | 10W/ft |
12HTR | 12W/ft |
5HTP | 5W/ft | Ex eb ⅡC T4 Gb,
Ex tb ⅢC T135°C Db | 110°C | Medium temperature |
10HTP | 10W/ft |
15HTP | 15W/ft |
20HTP | 20W/ft |
5HTS | 5W/ft | Ex eb ⅡC T3 Gb,
Ex tb ⅢC T200°C Db | 120°C | High temperature |
10HTS | 10W/ft |
15HTS | 15W/ft |
20HTS | 20W/ft |
Product name method:
Detail format of type is aHTXb-Cc,
‘a’ indicates the output power(W/ft) at 10°C 220VAC;
‘b’ indicates the voltage, ‘1’ for 110~120VAC, ‘2’ for 220~240VAC;
‘c’ indicates the outer jacket, ‘T’=Fluorpolymer, ‘R’=Thermoplastic.
+ The accessories:
Type | Description | Rated Voltage | Ex-proof marking | Operating temperature |
| PTBS-GET | Power, splice & tee connection box | 110~120VAC
or
220~240VAC | Ex eb ⅡC T6..T3 Gb,
Ex tb ⅢC T85°C...200°C Db | -40°C~200°C |
| JHS-GET | Splice junction box |
| JHT-GET | Tee connection junction box |
| JHE-GET | End seal junction box |
The active trace heating cable comprises two stranded copper conductors separated by a fluoropolymer spacer around which are wound, in a spiral, a number of carbon loaded polymer fibres which form the active part of the heating cable.
TYPE APPROVAL CERTIFICATE
No. ELE790725WS
Enclosure - Page 2 of 2
HT Series
An extruded layer of fluoropolymer covers the fibres and serves to insulate the copper conductors from a tinned
copper braid which covers the basic heater.
A protective anti corrosion fluoropolymer or thermoplastic outer jacket sheath may be extruded over the braid.
In this arrangements the unit is designated the HT series of Trace Heating Cable.
The declared maximum withstand temperature for the range is 85~200°C and the minimum installation temperature is -40°C.
2. Reference Documents
+ Manufacturer instruction filed by RINA with drawing No. SHEL-31743.
+ Specification of products filed by RINA with drawing No. SHEL-31742.
+Test Report field by RINA with drawing No. SHEL-31741.
+Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-31744.
+ Routine test report signed by attending Surveyor and filed by RINA with drawing No. SHEL-31749.
+ Technical Drawings and reports filed by RINA listed on Approval letter No.: SHEL/2026/970/YZ008.
3. Notes/ Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
.