MED057624CS!003ENGD- -  -  N- Fanflex 20F-SV/3 -N- S- S- -17/04/2025- Marine Equipment- - SN- S- - N-  - 692,947B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED057624CS/003- N-Apr 16, 2030692947
 
Form
  Marine Equipment(TO)
Certification N. MED057624CS/003 - (ENG)
Certificate date 17/04/2025
Type Protezione antincendio
Product Penetrations through "A" Class divisions: (b) pipe, duct, trunk, etc. penetrations
Item Nº MED/3.26b
USCG Category N° 164.138

Model or Denomin.
Items
Fanflex 20F-SV/3
Applicant BBV TECH SRL
Place of requester VIA PAPA GIOVANNI XXIII, 56  %  20090 Rodano (MI)  % ITALY
Tel. N.,Fax, Email +39 0295328118, 0295328316, ---
Directive (EU) 2024/1975
Standards IMO Res. MSC.307(88)-(2010 FTP Code) as amended - IMO MSC.1/Circ. 1488
Reference Documents SOLAS 74 Reg.II-2/9, IMO Res. MSC.1/Circ.1276 Rev.1, IMO Res. MSC.1/Circ.1655.
Request 15/02/2024
Expire date 16/04/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED057624CS/003

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.26b
USCG Category Nº 164.138
Description Penetrations through "A" Class divisions: (b) pipe, duct, trunk, etc. penetrations
Type Fanflex 20F-SV/3
Applicant BBV TECH SRL
VIA PAPA GIOVANNI XXIII, 56,20090 Rodano (MI),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP Code) as amended - IMO MSC.1/Circ. 1488
Reference standards SOLAS 74 Reg.II-2/9, IMO Res. MSC.1/Circ.1276 Rev.1, IMO Res. MSC.1/Circ.1655.
Issued in Genoa on
This Certificate is valid until
April 17, 2025
April 16, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED057624CS/003
Page 1 of 2
Product description
Product description

The pipe penetration is carried out by a steel cylinder min. Ø280 mm max. Ø2010 mm , height 160 mm and tickness 5 mm welded on the unexposed side of the deck. A steel pipe min. DN50, thickness 3.18 mm, max. DN1800, thickness 5 mm, pass inside the cylinder. On the pipe is welded a steel flange having “L”, Ø external min. 420 mm, max. 2160 mm, height 40 mm and thickness 5 mm. The gap between flange and penetration cylinder is 35 mm . Outside the penetration, on the unexposed side, a steel ring having min. Ø420 mm, max. Ø2160 mm, height 50 mm and thickness 5 mm, is welded on the deck. Inside the penetration on the exposed side, the pipe is insulated for a height of 595 mm from the welded flange on the pipe, by 2 layers of mineral wool having thickness 40 mm and density of 100 kg/m³, named Rockwool PROROX WM 960 with metallic net secured by steel wire. On the exposed side, externally to the up described insulation, for a height of 400 mm starting from the deck, are applied 3 layer of mineral wool thickness 40 mm and density of 100 kg/m³, named Rockwool PROROX WM 960 with metallic net secured by steel wire. At 100 mm from the deck, these insulations are fixed to the pipe using two rows of steel pins 200 mm apart, positioned every min. 60°, max. 120°. On the unexposed side, externally to the cylinder penetration, for a height of 190 mm from the deck, are applied 2 layers of mineral wool having thickness 40 mm and density 100 kg/m³, named Rockwool PROROX WM 960 with metallic net. On the unexposed side, externally to the pipe, for the entire height, from the welded flange, are applied 3 layers of mineral having thickness 40 mm and density 100 kg/m³ named Rockwool PROROX WM 960 with metallic net secured by steel wire. From the flange welded on the pipe and the ring welded on the deck, using inox clamps, are installed a gasket made of HT silicone named BBV Tech srl EVV051501, thickness, thickness 3 mm, density 1300 kg/m³ and one layer of glass fiber cover named rex thermoglas Gewebe 200 - 1300 kg/m².

Field of application

Fire resistant A-60 Class metal pipes penetration through Deck as per below table.
range Ø
min. 50 
max. 1800 
thick min. 
3.18  mm
5 mm
Reference documents

BBV-Tech drawing no. 1C-9313 dated 05/04/2024 and no 1C-9377 dated 18/09/2024.

Tests carried out

RINA Test Report No. 2024CS01576/3 issued on 20/04/2024 and No. 2024CS01576/4 dated 24/10/2024 according to IMO 2010 FTP Code.

Pressure Test Certificate ( test pressure 0.3 bar) No. CPI-Type Approval-01 (RINA 2024/MI/01/544) dated 11/07/2024 and No. CPI-Type Approval-03 (RINA 2025/MI/01/258) dated 16/04/2025, issued at BBV Tech S.r.l.





ATTACHMENT TO
CERTIFICATE No. MED057624CS/003
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****