MED071325CS!002ENG- -  -  N- MRN-BD-101-B15 (B-15 Class Door with kick out panel) -N- S- S- -31/03/2025- Marine Equipment- - SN- S- - N-  - 1,083,701B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED071325CS/002- N-Mar 30, 20301083701
 
Form
  Marine Equipment(TO)
Certification N. MED071325CS/002 - (ENG)
Certificate date 31/03/2025
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
MRN-BD-101-B15 (B-15 Class Door with kick out panel)
Applicant MERCAN PANEL URETIM SAN. VE TIC. A.S.
Place of requester ÇERKESLI OSB MAH., IMES BULVARI, No.11 DILOVASI, KOCAELI Kocaeli  % TÜRKIYE
Tel. N.,Fax, Email +90 262 502 0180, +90 262 502 0182, yasinyamac@mercanpanel.com
Directive (EU) 2024/1975
Standards IMO MSC.1/Circ. 1319,IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Request 10/02/2025
Expire date 30/03/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED071325CS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type MRN-BD-101-B15 (B-15 Class Door with kick out panel)
Applicant MERCAN PANEL URETIM SAN. VE TIC. A.S.
ÇERKESLI OSB MAH., IMES BULVARI, No.11 DILOVASI, KOCAELI Kocaeli,TÜRKIYE
Testing standards IMO MSC.1/Circ. 1319,IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Issued in Genoa on
This Certificate is valid until
March 31, 2025
March 30, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED071325CS/002
Page 1 of 3

Product description


Single leaf hinged door with maximum clear opening size 1100x2000 mm. The leaf, having maximum dimensions 1130x2030 mm and 37 mm thick, is composed, moving from the hinged side, of a carbon steel plate 1 mm thick, an insulating material composed of one layer of non-combustible material type Izocam Marine Firebatts 37 mm thick having density of 140 kg/m3, glued to the steel plates with glue type SikaForce 7710 L100 150 g/m2. Inside the leaf are provided the following carbon steel stiffeners: 2 vertical stiffener composed of "C" shaped profiles having dimension of 27x35x27 mm with a thickness of 2 mm each and 6 horizontal stiffeners: on the top and on the bottom of the leaf there are 2 "C" shaped profiles 62x35x62 mm with a thickness of 2 mm each; in the upper side of the leaf there is a "C" shaped profile 25x35x25 mm with a thickness of 2 mm; at the center of leaf there is "C" shaped carbon steel profile 11x35x11 mm with a thickness of 1 mm, the stiffeners are welded. The joint between the external and internal steel plates has done by an "C" stainless steel profile having dimensions of 11x40x11 mm and thick 1 mm fixed with steel rivets having a ranging pitch from 250 mm up to 500 mm and diameter of 4 mm. The leaf frame is fixed to the bulkhead by steel screw having diameter of 5 mm and a ranging pitch from 250 mm up to 500 mm. The leaf frame is to be insulated for a width of 200 mm all around, with mineral wool Rockwool type SeaRox SL 480 having thick 60 mm and density of 200 kg/m3 fitted by steel pins and washers. The leaf rabbet which is shielded with a gasket type Gulyol-AHC01 having diameter of 12 mm and width of 17 mm. The leaf contain a kick-out panel with maximum clear opening size 505 x 505 mm and a maximum dimensions of 500 x 500 mm and a thickness of 40 mm. The panel is composed by two carbon steel plates having thickness of 1 mm glued, with glue type SikaForce 7710 L100 150 g/m2, to one layer of mineral wool of non-combustible material type Izocam Marine Firebatts 37 mm thick having density of 140 kg/m3. The kick-out panel has two horizontal carbon steel stiffeners having dimension 25x35x25 mm and thickness of 2 mm, having a lenght of the entire width of the leaf; and two vertical carbon steel stiffeners having dimension 28x35x28 mm and thickness of 2 mm each. The leaf is provided of three stainless steel pivot hinges Mercan Panel and a one stainless steel mortise lock Mercan Panel.


 



ATTACHMENT TO
CERTIFICATE Nr. MED071325CS/002
Page 2 of 3

Field of application

Fire resistant B-15 Class door, for general application, installed on a A-60 Class bulkhead.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested
- door used with a fire tested frame design
Reference documents

Mercan Panel drawings No. 200150-B15 rev. 0 dated 05/08/2019 enclosed on the test report No. RFTR19187-REV1 issued on 26/03/2025 identified by No. 2025CS01713/2 attachment No.1.
Tests carried out

Tests as per Efectis laboratory test report No. RFTR19187-REV1 issued on 26/03/2025 according to IMO Res. MSC.307(88)-(2010 FTP Code), as amended.




ATTACHMENT TO
CERTIFICATE No. MED071325CS/002
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****