ATTACHMENT TO
|
CERTIFICATE Nr. MED087315CS
|
|
|
|
|
|
|
|
|
|
|
|
|
| Place of unit verification |
|
|
|
| Genova,, |
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
14-028-APCW-0001 DG1 Intended for ship COSTA DELIZIOSA |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
PRMT-11530 approved on 4th June 2015 : “COSTA DELIZIOSA Pumps” - 14-028-APCW-0004-R10-P&ID PUMPS PRMT-11531 approved on 4th June 2015 : “COSTA DELIZIOSA DG#1” - 14-028-APCW-0001-R11-P&ID
PRMT-11550 : “Exhaust Gas Cleaning System – Onboard Monitoring Manual” – 14-028-APC-OMM Rev.10thMay2015
PRMT-10549 : “Exhaust Gas Cleaning System – Technical Manual – Scheme B” – 14-028-APC_ETM-B Rev.10thMay2015
PRMT-11500 approved on 13th May 2015 : “SOx Emissions Compliance Plan” – 14-028-APC-SECP
- - - - - - - - - - - - -
ECG System ECO-DeSOx consisting of the following verified components:
EGC tower (ECOSPRAY TECHNOLOGIES / ECO-DeSOx / 14-028-APCW-0001 DG1) Sprayer nozzles (PNR / AAU2780L61 / AAU3194N6SG) SW Pump (POMPE GARBARINO / MU200-315L) SW Pump Motor (ABB / M3BP 315LKA) Dilution Pump (POMPE GARBARINO / MU250-250LDS) Dilution Pump Motor (ABB / M3BP 280SMB6L) Automatic Self-Cleaning SW Filter (Filtrex / ACB-955-300) Static Mixer (ECOSPRAY TECHNOLOGIES / SM01-300) PAH Sensors (Hach Lange / FP 360 sc) pH Sensors (Hach Lange / pHD sc Digital Differential pH) Turbidity Sensors (Hach Lange / Ultraturb sc) Free O2 Sensor (Hach Lange / LDO Sensor) Conductivity Sensor (Hach Lange / 3700 sc) Gas Analyzer (Kittiwake Procal Ltd. / PROCAL 2000) SW Pump Inverter (Danfoss / FC-102N200T4E54H2TGR3/134N8651-000206H384) Dilution Pump Inverter (Danfoss / FC- 102P55KT4P55H5TGC1/134N6578-010504G374) PLC Panel (ECOSPRAY TECHNOLOGIES / Main Panel 01) VDU Touchscreen 10” (SIEMENS / 6AV6643-0CD01-1AX1) - - - - - - - - - - Tests carried out:
EGCS Statutory Survey Report, doc. No. MAC167315CS. RINA job. ID. RS/2015/CS/01/1673 and RS/2015/CS/01/873 and RS/2014/CS/01/3590
|
Limitation on the acceptance or use of the
product
In scheme B, according to MEPC.184(59), compliance with emission requirements is demonstrated by continuous exhaust gas monitoring.
EGCS acceptance and use to be within the terms and conditions of “Procedure for Compliance” at Para. 6 of PRMT-11500 approved on 13th May 2015 : “SOx Emissions Compliance Plan” – 14-028-APC-SECP.
Monitoring system is subject to periodic surveys by RINA according to MEPC.184(59).
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|