Bulkhead consisting of panels having maximum height of 2400 mm and maximum width of 600 mm. Such panels are composed of a mineral wool layer fitted with glass veil, (certified non combustible in conformity to the requirements of the IMO FTP Code), 15 mm thick and having density of 140 kg/m3 or 160 kg/m3 named PAROC Marine Slab 160 N8 or mineral wool layer, (certified non combustible in conformity to the requirements of the IMO FTP Code), 15 mm thick and having density from 140 kg/m3 up to 220 kg/m3 named ROCKWOOL Searox SL488, glued to a steel sheet having thickness of 0.7 mm by means of 140 g/m2 of glue named PROPTOPUR AE100 or glue named SIKAFORCE 7110 L35 or glue named SIKAFORCE-110. The panel joints consist of āLā shaped sheet bent edges, relevant locking and fixing by means of screws fitted with pitch of 350 mm. The bulkhead is fitted on perimeter sides, with U shaped steel profiles, 3 mm thick and having dimensions of 50x35 mm. The panel steel sheets are fixed to these profiles by means of screws fitted with pitch of 200 mm
The bulkhead may be fitted, at the maximum height of 2130 mm, with metallic box, not externally insulated, 40 mm deep and having maximum dimensions of 300x100 mm, composed of steel sheet having thickness of 0.6 mm.Field of application Fire resisting B-0 Class bulkhead for general applications.
Reference documents Marine Interiors Cabins SpA drawings No. 24PC00351 and No. 24PC00348, dated 22 December 2020, enclosed to DBI test reports No. PGB10069A and No. PGB10069B dated 26 February 2021.
Marine Interiors Cabins SpA drawings No.+24PC00348.01 rev 0.1 and No. +24PC00351.01 rev. 0.1 dated 22 May 2024,
Tests carried out Tests as per DBI Test Laboratory reports No. PGB10069A and No. PGB10069B issued on 26 February 2021 according to IMO 2010 FTP Code Part 3.
Tests as per RINA Test Laboratory reports No. 2024CS01208/5 and 2024CS01208/6 issued on 23 February 2024, according to IMO 2010 FTP Code Part 3. |