Single leaf hinged door with maximum clear light of 1000x2000 mm (WxH). The leaf, having maximum dimensions of 1040x2015 mm (WxH), is composed of two steel sheets having thickness of 1 mm and, in between, the insulating material composed of a layer of mineral wool (certified non-combustible in conformity to the requirements of the IMO FTP Code) having density of 150 kg/m3 and thickness of 33 mm.
The leaf is fitted with four stiffeners made of U-shaped steel profiles having dimensions of 25x33x25 mm and thickness of 1.5 mm, internally insulated by means of non-combustible material type Neptune Sheet.
The door is fitted with a locking system with lock type Trioving 5316, a handle type Trioving, two thermal bolts type Dictator and three stainless steel hinges. The door frame and counterframe, composed of steel profiles having thickness of 1 mm, are fixed to the bulkhead by means of screws 3.5x20 mm with pitch of 400 mm.
The door may be fitted with a window having clear light of 470x470 mm, composed of a glass type Pyrobel 16, 17 mm thick. The window’s frame, composed of steel profiles, is completed with strips of material type Isofrax 1260 °C Paper.
The door may also be fitted with a ventilation grille, completed with strips of intumescent material type Kerafix 8x1 mm.
Field of application Fire resistant B-15 Class single leaf hinged door with the fire hazard on both sides in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf;
- maximum door size tested;
- door used with a fire tested frame design.
The surfaces of this division may be fitted with products having low flame spread characteristics, installed as described in the relevant type approval certificates and satisfying the requirements of SOLAS 74 Reg. II-2 as applicable.
Reference documents A.PAPADOPOULOS & CO G.P. drawing No. HB-B15-120 Rev. E dated 7 December 2020 approved on 11 June 2021 with endorsement No. LABS-2244.
Tests carried out Test as per RINA Test Laboratory report No. 2021CS011765 issued on 11 June 2021 according to IMO 2010 FTP Code Part 3. |