MED183323CS!002ENGB- -  -  N- IDRA WD -N- S- S- -15/05/2023- Marine Equipment- - SN- S- - N-  - 781,145B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità- MED183323CS/002- N-Dec 28, 2027781145
 
Form
  Marine Equipment(TO)
MED183323CS/002
Certification N. MED183323CS/002 - (ENG)
Certificate date 15/05/2023
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
IDRA WD
Applicant OLCESE RICCI SRL
Place of requester VIA CAORSI 49  %  16030 SORI (GE)  % ITALY
Tel. N.,Fax, Email 0185700425, 0185700900, info@olcesericci.com
Directive (EU) 2022/1157
Standards IMO Res. MSC.307(88)-(2010 FTP Code) - IMO MSC.1/Circ. 1319
Reference Documents Chap. II-2 of SOLAS 74 Convention, as amended, RINA Rules for the certification of Marine Equipment
Request 13/9/2016
Expire date 28/12/2027
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED183323CS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2022/1157.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type IDRA WD
Applicant OLCESE RICCI SRL
VIA CAORSI 49,16030 SORI (GE),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP Code) - IMO MSC.1/Circ. 1319
Reference standards Chap. II-2 of SOLAS 74 Convention, as amended, RINA Rules for the certification of Marine Equipment
Issued in Genoa on
This Certificate is valid until
May 15, 2023
December 28, 2027
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED183323CS/002
Page 1 of 3




Product description

Double leaf hinged door whose maximum clear opening size is 3000 mm wide and 2050 mm high. The door leaves, having maximum height of 2141 mm and maximum width of 1569 mm (primary leaf) and 1591 (secondary leaf) are composed of a steel sheet, 2 mm thick, one layer of PROMAGUARD ALU (thickness of 10 mm and density of 240 kg/m3), two layers of mineral wool type PAROC MARINE FIRE SLAB 150 or ROCKWOOL SEAROX SL 440 (thickness of 40 mm each and density of 150 kg/m3), a PROMAGUARD ALU layer and a steel plate having thickness of 3 mm. Inside the leaves, four transversal steel stiffeners having height of 40 mm and thickness of 4 mm, are welded, to the steel plate having thickness of 3 mm, with pitch of 412 mm. The door frame is composed of an hollow steel profile having thickness of 5 mm and dimensions of 125x95 mm welded to the bulkhead or bolted by means of bolts fitted with pitch of 140 mm. The door closure is made tight with a gasket fitted in the bended edge on the rabbet which is shielded with a thermo-expanding gasket type PROMASEAL LSK having thickness of 2,5 mm fitted on the perimeter edge leaf. The door may be fitted with a rectangular window having maximum clear light of 300x400 (WxH) mm; the glass compound, type PYROBEL 25 EI 60 (manufacturer AGC) and having minimum total thickness of 26.6 mm, is composed of five panes and, in between, four layers of thermo-expanding gel. The window frame is composed, on both sides, of a steel profile having thickness of 2 mm fixed to the leaf by means of M6 screws. Between glass and frame SuperwoolX607 gaskets, having thickness of 5 mm are fitted; the glass is sealed by means of silicone type PROMAT SYSTEMGLAS. The door is fitted with eight active dog bolts named Firebolt A2.Long stroke; six on the primary leaf and two on the secondary leaf. The door is fitted with latches that act on three points (primary leaf) and two points (secondary leaf). Moreover is equipped with a lever closing device, on the side opposite to the hinges, that acts on 7 points (primary leaf) and four points (secondary leaf) actuated, each, by an handle.








 



ATTACHMENT TO
CERTIFICATE Nr. MED183323CS/002
Page 2 of 3


Field of application

Fire resistant A-60 Class double leaf hinged door also in case the door is closed with the latch only.
Fire resistant A-60 Class double leaf hinged door in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions tested relevant to the width and height of the door (2150 mm and 2050 mm) may be increased of 15% provided that the surface area is not increased of more than 10% (Olcese Ricci drawings No. 17001 dated 14 February 2017 and 17002 dated 18 January 2017 approved on 6 March 2017 respectively with endorsement No. LABS-1422 and No. LABS-1423).
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf
- maximum door size tested
- door used with a fire tested frame design



Reference documents

Olcese Ricci drawing No. 17184 Rev. 1 dated 20 December 2017 approved on 28 December 2017 with endorsement No. LABS-1593.


Tests carried out

Test as per RINA Test Laboratory Report No. 2017CS01300 issued on 6 March 2017 according to IMO 2010 FTP Code Part 3. Increased dimensions verified with Technical Report No. 2017/12/TCHU dated December 2017




ATTACHMENT TO
CERTIFICATE No. MED183323CS/002
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****