Materials/Components
Medium voltage power cables low smoke, halogen free, flame retardant, fire resistant (see remarks *), for fixed installation on ships and offshore units.
Rated voltage: 3.6/6 kV; 6/10 kV; 8.7/15 kV; 12/20, kV
Type: FIREBAR ® XAI MV
Maximum rated temperature: 90°C
Marking: CCI FIREBAR ® XAI MV voltage rate n X s mm2 IEC 60092-354 IEC 60332-3-22 Cat A BS 8491 F120 meter marking Year QA n°
Construction:
conductor: tinned annealed copper conductor (according to IEC 60228)
semiconductors: extruder compound LSOH
insulation HF-HEPR + halogen free heat resistant insulating compound
phase screen: tinned copper tape
firebar protection: fibreglass tapes + fiberglass ropes, HEPR sheathed
inner sheath: halogen free heat resistant rubber compound
electromagnetic shield: plain copper tapes
armour: tinned copper wires braid
outher sheath: SHF2 or SHF1 compound
Standards:
In accordance with IEC 60228; IEC 60092-350; IEC 60092-360; IEC 60092-354; IEC 60332-1-2; IEC 60332-3-22 Cat.A; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2 ; RINA Rules; RINAMIL Rules; RINA Rules for FSRU; RINAMIL for FREMM; RINA Rules for FPV.
Fire Resistance with Mechanichal Shocks and Water Jets according to Standards; BS 8491:2008 F120.
Cold Bend and Impact Test at Low Temperature (-40C°) according to Standards CSA C 22.2 N. 0.3-01 & N. 38-05
Remarks:
(fire resistant *) = the fire resistant characteristics with mechanical shocks, water spray and water immersion tests were tested in accordance with internal CCI Test Procedure N.FBMT/PR 15-20 Rev.2 dated 22/07/2010 ( refers to Standards BS 8491:2008 F120.),
Technichal Specification:
FIREBAR MV IEC N. Doc.FBMV-IEC/612RI/TA Rev.01 4/17, N. 4 pages.
Test Reports/ Documents:
IMQ N. 01SL00222 dated 2012/04/05.
IMQ N. 01SL00128 dated 2012/04/05.
CCI N. FBMT/PR15-20/1 Rev.2.
CCI N. FBMT/PR15-20/2 Rev.2.
CCI Tests Certificate N. FB MV - FMWJ/120 dated 23/03/2016.
CCI letters N. CCI 023-12L dated 26/07/2012.; N. CCI 024-12L dated 26/07/2012; N. CCI 025-12L dated 26/07/2012.
CCI letters N. Doc.021.17 TR dated 16/10/2017; Doc. N. 022-17 RI/TA dated 16/10/2017.
TYPE APPROVAL CERTIFICATE
N° ELE197118CS/001
Enclosure - Page 2 of 2
FIREBAR ® XAI MV
.
Components for electric plants to be used according to the instructions given by the manufacturer.
The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates
Type Approval certifies that a rappresentative sample of the products has been found to meet the applicable design criteria
Any modification of change shall not be valid until approval is granted by RINA as a result of due assessment.