ELE220124PUENG- -  -  N- LSLV-H100 Series -N- S- S- -22/01/2025- Prodotti Elettrici- - SN- N- - N-  - 892,343BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE220124PU- N-Jan 22, 2030892343
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE220124PU - (ENG)
Certificate date 22/01/2025
Type Impianti Elettrici
Product CONVERTITORI DI FREQUENZA

Model or Denomin.
Items
LSLV-H100 Series
Applicant LS ELECTRIC CO., LTD. - CHEON AN PLANT
Place of requester 56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu,  %  31226 Cheonan-si (Chungcheongbuk-do)  % REPUBLIC OF KOREA
Tel. N.,Fax, Email ---, +82 41 550 8270, hlshin@lselectric.co.kr
Standards Rules for the Classification of Ships - Part C - Machinery, Systems and fire protection - Ch.3, Sect.6, Tab.1.
Expire date 22/01/2030
Head Office BUSAN
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE220124PU
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description FREQUENCY CONVERTERS
Type LSLV-H100 Series
Applicant LS ELECTRIC CO., LTD. - CHEON AN PLANT
56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu,
31226 Cheonan-si (Chungcheongbuk-do)
REPUBLIC OF KOREA
Reference standards Rules for the Classification of Ships - Part C - Machinery, Systems and fire protection - Chapter 3, Section 6, Table 1
  

 
 
   .   This Certificate is valid until January 22, 2030
_________________________________
RINA Services S.p.A.
Ho Seok Yang
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE220124PU
Enclosure - Page 1 of 1
LSLV-H100 Series
Product Description
+ The H-100 Series is a Converter for Fan and Pump Drive Control using Frequency

Main features

+ Control Method : V/F control, Slip Compensation
+ Frequency setting power : Digital command 0.01 Hz, Analogue command 0.06 Hz (60 Hz Standard)
+ Overload Capacity : 0.75~90kW : Rated Current : 120% 1 min. / 110~500kW : Rated Current : 110% 1min.
+ IP degree : IP20(0.75~185kW), IP00(220~500kW)
+ Storage temperature : -20 ~ 65 C Deg.
+ Output Frequency : 0-400 Hz
+ Input Frequency: 3ph : 50~60 Hz / 1ph : 60 Hz
+ Frequency Setting : Analogue type : -10~10V, 0~10V, 0~20mA, Digital type : key pad, pulse train input

Model
Applied Motor(kW)
Rated Capacity(kVA)
Rated Output
Current(A)
3ph/1ph
Rated Input Current(A)
Output Voltage(V)
3ph
H100 0008-2
0.75
1.9
5/2.9
4.9
200~240
H100 0015-2
1.5
3.0
8/4.4
8.4
H100 0022-2
2.2
4.5
12/6.4
12.9
H100 0037-2
3.7
6.1
16/8.4
17.5
H100 0055-2
5.5
8.4
22/11
23.7
H100 0075-2
7.5
11.4
30/16
32.7
H100 0110-2
11
16
42/23
46.4
H100 0150-2
15
21.3
56/30
62.3
H100 0185-2
18.5
26.3
69/37
77.2
H100 0008-4
0.75
1.9
2.5/1.6
2.4
380~480
H100 0015-4
1.5
3
4/2.4
4.2
H100 0022-4
2.2
4.5
6/3.5
6.5
H100 0037-4
3.7
6.1
8/4.6
8.7
H100 0055-4
5.5
9.1
12/6.8
12.2
H100 0075-4
7.5
12.2
16/9.2
17.5
H100 0110-4
11
18.3
24/14
26.5
H100 0150-4
15
23
30/17
33.4
H100 0185-4
18.5
29
38/22
42.5
H100 0220-4
22
34.3
45/26
50.7
H100 0300-4
30
46.5
61/36
69.1
H100 0370-4
37
57.1
75/39
69.3
H100 0450-4
45
69.4
91/47
84.6
H100 0550-4
55
82
107/55
100.1
H100 0750-4
75
108.2
142/73
133.6
H100 0900-4
90
128.8
169/86
160
H100 1100-4
110
170
223(3ph)
215.1
380~500
H100 1320-4
132
201
264(3ph)
254.6
H100 1600-4
160
248
325(3ph)
315.3
H100 1850-4
185
282
370(3ph)
358.9
H100 2200-4
220
329
432(3ph)
419.1
H100 2500-4
250
367
481(3ph)
469.3
H100 3150-4
315
467
613(3ph)
598.1
H100 3550-4
355
520
683(3ph)
666.4
H100 4000-4
400
587
770(3ph)
751.3
H100 5000-4
500
733
962(3ph)
938.6
* All convertors are to be installed inside enclosed panel.


Reference Documents
+ Technical Document: LS ELECTRIC's system Specification for Frequency Converter (Inverter-H100 Series) Ver1.0 in March, 2019
+ Test report: DT&C's Environment Test Reports: Ref. No. DRCREL1911-0859 dated 29/11/2019, EMC Test Report Ref. No. DREETC1911-0222 dated 28/11/2019, DRCREL1911-0867 dated 29/11/2019, DREETC1911-0223 dated 28/11/2019
+ Visual Inspection & Performance Test: LS ELECTRIC's Performance Test Report for renewal ref. no. LSEQA-RT-RINA-1 dated 17/12/2024 attended by RINA Surveyor.
+ Asbestos-Free Declaration (SOLAS II-1/reg.3-5) : LS ELECTRIC's official letter dated 15/05/2019


Note/Remark
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
+ Software Type Approval is not included in the scope of this certificate.
+ Location : general power distribution zone except bridge and deck zone

BUSAN January 22, 2025
**** NOTICE: This is NOT an official certificate ****