Double leaf hinged door with maximum clear opening size of 1500 mm (W) and 1890 mm (H) and having radiused corners with radius of 180 mm. The door leaves, having thickness of 116 mm, maximum height of 1970 mm and maximum width of 610 mm (secondary leaf) and 957.5 (primary leaf), are composed of a steel plate 4 mm thick having the edges bent on the rabbet, of a steel sheet 2 mm thick, fitted in the opposite side. Between the steel plate and the steel sheet is fitted the insulating material composed of two layers of material type PROMAGUARD, 10 and 6 mm thick and having density of 240 kg/m3 fixed to the steel sheet having thickness of 2 mm by means of steel pins and washers welded with density of 15 per m2. The leaves are fitted, inside, with T shaped steel stiffeners having dimensions of 40x40 mm and thickness of 6 mm, welded to the steel plate having thickness of 4 mm. The secondary leaf is equipped with No. 13 stiffeners (12 transversal and 1 longitudinal) whereas inside the primary leaf 16 stiffeners (14 transversal and 2 longitudinal), are fitted. The door frame is composed of a carbon steel angular having dimensions of 100x75x7 mm that makes the closure tight with the gasket fitted in the leaf bent edges. The secondary leaf is fitted with No. 5 external closure points welded to the frame; the primary leaf is equipped with a lever closing device, that acts on 10 points, fitted inside the leaf and actuated by the handle.
The primary leaf may also be fitted with No. 2 external closing points.
|
ATTACHMENT TO
CERTIFICATE No. MED456224CS
Page 2 of 3 |
Field of application
Fire resistant A-60 Class double leaf hinged door.
Fire resistant A-30 Class double leaf hinged door in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and with of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested;
- door used with a fire tested frame design.
The surfaces of this division may be fitted with products having low flame spread characteristics, installed as described in the relevant type approval certificates and satisfying the requirements of SOLAS 74 Reg. II-2 as applicable.
Reference documents
- Officina Meccanica Mariani drawing No. OMP50A60X.D dated 6 December 2012 approved on 25 July 2013 with endorsement No. LABS-806.
- Mariani drawing No. R-C351-900-162 dated 24 September 2024 enclosed to job No. 2024CS014562 (for external closing points on the primary leaf).
Tests carried out
Tests as per RINA Test Laboratory Report No. 2013CS012228 issued on 25 July 2013 according to IMO 2010 FTP Code Part 3 and to IMO MSC.1/Circ. 1319 dated 11 June 2009.
|