ELE020422CS!001ENGD- -  -  N- G-NF -N- S- S- -28/10/2022- Prodotti Elettrici- - SN- N- Luigi Benedetti- N-  - 1,151,592Luigi BenedettiBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE020422CS/001- N-Oct 28, 20271151592
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE020422CS/001 - (ENG)
Certificate date 28/10/2022
Type Impianti Elettrici
Product CAVI ELETTRICI

Model or Denomin.
Items
G-NF
Applicant G.C.E. CAVI ELETTRICI srl
Place of requester Strada Argine dei confini, 4  %  43016 Polesine Zibello (PR)  % ITALY
Tel. N.,Fax, Email +39-0524-96492, ---, luca.migliorati@gcecables.it
Standards RINA Rules for the Classification of Ships Pt C, Ch 2, Sec 9,IEC Standards (see Enclosure)
Expire date 28/10/2027
Head Office Genova
Interrut.senza Dettaglio ENG
Vuoto Scelto Certificato
S
TYPE APPROVAL CERTIFICATE
No. ELE020422CS/001
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC CABLES
Type G-NF
Applicant G.C.E. CAVI ELETTRICI srl
Strada Argine dei confini, 4
43016 Polesine Zibello (PR)
ITALY
Reference standards RINA Rules for the Classification of Ships Pt C, Ch 2, Sec 9,IEC Standards (see Enclosure)
  

 
 
   .   This Certificate is valid until October 28, 2027
_________________________________
RINA Services S.p.A.
Luigi Benedetti
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE020422CS/001
Enclosure - Page 1 of 1
G-NF
Materials/Components

Shipboard power and control cables, halogen free with low smoke emission, fire resistant, flame retardant, for fixed installations in marine and offshore units.

Rated voltage: 0.6/1 kV

Type: G-NF.

Marking: CGE Type of Cables - n X s mm2 - 0.6/1 kV IEC 60332-1-2 / IEC 60332-3-22 IEC 60331-1 (or 60331-2) FIRE RESISTANT - month-year - lenght marking.

Construction:

conductor: stranded plain copper conductor (IEC 60228 Class 5 )

mica glass foil overlapped on easch conductor
insulation: XLPE
assembly: conductors cabled with optimal lay-lenght
sheath: SHF1

Max. conductor temperature: +90°C.

In accordance to
rules IEC 60228 cl.5; IEC 60092-350; IEC 60092-360: IEC 60092-353; IEC 60331-1; IEC 60331-2; IEC 60332-1-2; IEC 60332-3-22 Cat. A; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2; RINA Rules; RINAMIL Rules; RINA Rules for FSRU; RINAMIL for FREMM; RINA Rules for FPV;

Technical specification: Technical Datasheet N. 077-2021 Rev. 3 - 26/04/2022.

Test Reports:

IMQ N. CN22-0077545-01 Rev.1 dated 23/08/2022; IMQ N. CN22-0077545-02 Rev.0 dated 10/10/2022;

IMQ N. CN22-0077545-03 Rev.0 dated 10/10/2022; IMQ N. CN22-0077545-01 dated 08/06/2022;

IMQ N. CN22-0077549-01 dated 28/04/2022; IMQ N.CN22-0077549-02 dated 28/04/2022.


CSI N. 0789/DC/REA/22_1 dated 13/06/2022; CSI N. 0789/DC/REA/22_2 dated 13/06/2022;

CSI N. 0789/DC/REA/22_3 dated 13/06/2022; CSI N. 0786/DC/REA/22_2 dated 08/06/2022;

CSI N. 0786/DC/REA/22_3 dated 08/06/2022.


Note/Remarks:
The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates
Type Approval certifies that a reppresentative sample of the products has been found to meet the applicable design criteria
Any modification of change shall not be valid until approval is granted by RINA as a result of due assessment


Genova October 28, 2022