MED722126WS!016ENG- -  -  N- DXPSY-1 -N- S- S- -24/08/2026- Marine Equipment- - SN- S- - N-  - 1,057,196B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED722126WS/016- N-Nov 29, 20281057196
 
Form
  Marine Equipment(TO)
Certification N. MED722126WS/016 - (ENG)
Certificate date 24/08/2026
Type Protezione antincendio
Product Mobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck
Item Nº MED/3.69

Model or Denomin.
Items
DXPSY-1
Applicant JIANGSU DINGXIANG MARINE EQUIPMENT CO., LTD.
Place of requester NO.77 XINJIAO ROAD, XINJIE TOWN % DONGTAI CITY, JIANGSU PROVINCE % CHINA
Tel. N.,Fax, Email 0515-85752008, 0515-85751100, info@dx-marine.com
Directive (EU) 2025/1533
Standards IMO MSC.1/Circ.1472
Reference Documents SOLAS 74 Reg.II-2/10, SOLAS 74 Reg.II-2/19, IMO Res. MSC.98(73)-(FSS Code) 12, IMO MSC.1/Circ.1472, IMO MSC.1/Circ.1550.
Request 2026/08/14
Expire date 29/11/2028
Responsible Office SHANGHAI
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Zhi Yuan Tan S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED722126WS/016

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.69
Description Mobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck
Type DXPSY-1
Applicant JIANGSU DINGXIANG MARINE EQUIPMENT CO., LTD.
NO.77 XINJIAO ROAD, XINJIE TOWN,DONGTAI CITY, JIANGSU PROVINCE,CHINA
Testing standards IMO MSC.1/Circ.1472
Reference standards SOLAS 74 Reg.II-2/10, SOLAS 74 Reg.II-2/19, IMO Res. MSC.98(73)-(FSS Code) 12, IMO MSC.1/Circ.1472, IMO MSC.1/Circ.1550.
Issued in SHANGHAI on
This Certificate is valid until
August 24, 2026
November 29, 2028
This Certificate consists of this sheet plus an attachment

________________________________________
Peng Fang
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED722126WS/016
Page 1 of 3

Field of Application

Mobile Water Monitor is used for Protection of On Deck Container Stacks, in accordance with Reg.II-2/10.7.3.2 of
SOLAS '74 as amended.
Technical Data
Main Components: Inlet fitting, Monitor waterway, Swivel fittings, Discharge nozzle and a shut-off device, Carrying handle.

Nominal Capacity: 60 m3/h (1000 L/min) @ 0.4 Mpa


Nominal Working Pressure: 0.4 Mpa
Maximum Working Pressure: 1.0 Mpa
Nominal Throw Length: 40 meters @ 0.4 Mpa
Pivoting Area: Horizontal, 270 °; Vertical, 0 ° to 90 °
Weight: ≤ 23 Kg
Nozzle Type: Dual-purpose Spray/Jet
Water Inlet Dimension: DN50
Corrosion Resistant Materials: SS316 & Anti-corrosion Copper Alloy
Reference Document
The design assessment is based on IMO Resolution MSC.365(93) with following documents:
- Instruction Manual, filed by RINA with No.: SHFP-26942;
- Bill of Material, filed by RINA with No.: SHFP-26944;
- Technical Drawing of Mobile Water Monitor, approved by RINA with No.: SHFP-26945;
- Technical Specification, filed by RINA with No.: SHFP-26946;
- Marking, filed by RINA with No.: SHFP-26947.
Production and Tests
The production must be carried out in accordance to the manufacturer quality production system.
Tests has been carried out and witnessed by RINA Surveyor in compliance with IMO MSC.1/Circ.1472 (Guidelines for the design, performance, testing and approval of mobile water monitors used for the protection of on-deck cargo areas of ships designed and constructed to carry five or more tiers of containers on or above the weather deck). Relevant test report has been filed by RINA with No.: SHFP-26949.





ATTACHMENT TO
CERTIFICATE No. MED722126WS/016
Page 2 of 3
Remark
Mobile Water Monitors should be equipped with a coupling allowing connection to the ship's fire hydrants by fire hoses. The coupling should be sized so as to ensure that the flow and pressure needed for correct performance will be provided.

The manufacturer's operating guidelines includes information on the safe operation of the monitors to be observed.


Note
This certificate annuls and replaces the certificate No. MED248624WS due to Change EU Authorised Representative.




ATTACHMENT TO
CERTIFICATE No. MED722126WS/016
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Peng Fang
**** NOTICE: This is NOT an official certificate ****