Self-contained compressed-air-operated breathing apparatus is designed in two different version with the following main characteristics:
Module | Max
Working
Pressure | Volume | Air Deposit | Using Time | Weight (Kg) | Packing Size (mm) | Working Temperature Range |
RHZK6-1 | 30 Mpa | 6 L | 1800 L | ≥30 min | ≤ 18 | 700 x 430 x 290 | -30 °C to 60 °C |
RHZK6.8-1 | 30 Mpa | 6.8 L | 2040 L | ≥30 min | ≤ 12 | 700 x 430 x 290 | -30 °C to 60 °C |
Main Components
Components | Model | Manufacturer |
Pressure Cylinder | 6 L or
6.8 L | Jiangsu Jiuwei High Pressure Vessel Manufacture Co., Ltd
(6 L, Steal Cylinder)
or Shenyang Zhougfu Kejin Pressure Vessels Co., Ltd
(6.8 L, Fully Wrapped Composite Cylinder) |
Air Cylinder Valve | -- | Zhejiang Yu'an Fire Equipment Co., Ltd |
Pressure Reducer | DSPR-1 | Jiangsu Yigu Security Technology Co., Ltd |
Air Supply Valve | DSG-1 | Jiangsu Yigu Security Technology Co., Ltd |
Full-face Mask | DSM-1 | Jiangsu Yigu Security Technology Co., Ltd |
Fireproof Lifeline | DXNHS | Jiangsu Dingxiang Marine Equipment Co., Ltd |
Electrical Pressure Gauge and Rest Air Warning System, or
Mechanical Pressure Gauge and Rest Air Warning System | -- | Jiangsu Yigu Security Technology Co., Ltd |
Back Frame and Harness | -- | Jiangsu Yigu Security Technology Co., Ltd |
SCBA Box | -- | Jiangsu Dingxiang Marine Equipment Co., Ltd |
Breathing Resistance at low temperatures: The exhalation resistance shall not exceed 1 kPa.
Breathing Resistance at high temperature: The exhalation resistance shall not exceed 1 kPa.
Breathing Resistance (Inhalation resistance, Exhalation resistance) has been tested according to EN 13274-3, method 2 (settings E and H shall be used).
 | ATTACHMENT TO
CERTIFICATE No. MED258523WS/006
Page 2 of 3 |
]Field of Application
Self-contained compressed-air-operated breathing apparatus for shipboard use for fire-fighters, Type 1 mask shall not be used.
Reference Documents
Operation, Installation and Servicing Manual, filed by RINA with No. SHFP-12165;
Technical Specification, approved by RINA with No. SHFP-12166;
Bill of Material, approved by RINA with No. SHFP-12788;
Nameplate, approved by RINA with No. SHFP-12168;
Technical Drawing, approved by RINA with No.: SHFP-12177;
Gas Cylinder Certificate (6L) (Ref No.: 0036-021-16 Rev.0), filed by RINA with No.: SHFP-12176;
Gas Cylinder Certificate (6.8L) (Ref No.: CE-PED-B-ZKJ 002-15-CHN), filed by RINA with No.: SHFP-12175.
Test Carried Out
Tests Carried Out in accordance with EN 136 (1998) including AC (2003), EN 137 (2006) and ISO 23269-2:2011 as below:
- Test Report (RHZK6.8-1, Ref No.:2018040) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances and filed by RINA with No.: SHFP-12155;
- Test Report (RHZK6-1, Ref No.:2018039) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances and filed by RINA with No.: SHFP-12156;
- Test Report (Full Face Masks) (Ref No.: 2018042) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances and filed by RINA with No.: SHFP-12157;
- Test Report (RHZK6.8-1, Ref No.:201818) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances and filed by RINA with No.: SHFP-12704;
- Test Report (RHZK6-1, Ref No.:2018117) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances and filed by RINA with No.: SHFP-12703.
Remarks
Both types of SCBA have been designed in compliance with MSC.338(91) and MSC.339(91).
The SCBA can be equipped with different EC Type Approved Gas Cylinder of same capacity and Fireproof Lifeline in compliance with Directive 2014/90/EU as amended.
The breathing air shall comply with the requirements of EN 132. Each SCBA shall be marked according to ISO 23269-2:2011(E), Par.9. The markings shall be as required by the specified standards and shall also include the EC “Mark of Conformity" according to the Directive. The compressed air cylinder markings shall include the charging pressure, capacity and the stamp of the authorized inspection body.
Additional information shall be supplied by the manufacturer after delivery. A set of manufacturer’s instructions shall accompany every unit and should be kept onboard. Manufacturer’s instructions for application / limitations, checks prior to use, donning and fitting, use, cleaning and disinfection, maintenance and storage shall be adhered to. Use and maintenance only by trained and qualified persons.
Note
Renewal of Previous EC Type Examination (Module B) Certificate No.: MED122418WS/002, initial condition is kept.