ATTACHMENT TO
|
CERTIFICATE Nr. MED352015CS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
14-130-APCW-0100 DG6 Intended for ship COSTA MAGICA |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
PRMT-12196 approved on 10 November 2015 : “COSTA MAGICA Pumps” - 14-130-APCW-0011-R02-P&ID PRMT-12197 approved on 20 November 2015 : “COSTA MAGICA Pumps” - 14-130-APCW-0010-R05-P&ID PRMT-12198 approved on 20 November 2015 : “COSTA MAGICA DG#6” - 14-130-APCW-0005-R03-P&ID-DG6
PRMT-12425 approved on 27 November 2015 : “Exhaust Gas Cleaning System – Onboard Monitoring Manual” – 14-130-APC-OMM rev.28th Oct 2015
PRMT-12424 approved on 27 November 2015 : “Exhaust Gas Cleaning System – Onboard Monitoring Manual” – 14-130-APC-OMM rev.28th Oct 2015
PRMT-12426 approved on 27 November 2015 : “SOx Emissions Compliance Plan” – 14-130-APC-SECP rev.28th Oct 2015
- - - - - - - - - - - - -
ECG System ECO-DeSOx consisting of the following verified components:
EGC tower (ECOSPRAY TECHNOLOGIES / ECO-DeSOx / 14-130-APCW-0100 DG6) Sprayer nozzles (PNR / AAU2780L61) SW Pump (ALLWEILER / MI200-315/41/350 U3 .19D-S-W133) SW Pump Motor (VEM / 175 kW) Dilution Pump (ALLWEILER / MI250-315/43/310 U3.19D-S-W133) Dilution Pump Motor (VEM / K11R250M6 E1 IE2 HB IL KV LL NSTPMTUHW 40 kW) Automatic Self-Cleaning SW Filter (Filtrex / ACB-955-300) Static Mixer (ECOSPRAY TECHNOLOGIES / SM01-300/400) PAH Sensors (Hach Lange / FP 360 sc) pH Sensors (Hach Lange / pHD sc Digital Differential pH) Turbidity Sensors (Hach Lange / Ultraturb sc) Free O2 Sensor (Hach Lange / LDO Sensor) Conductivity Sensor (Hach Lange / 3700 sc) Gas Analyzer (Kittiwake Procal Ltd. / PROCAL 2000) SW Pump Inverter (Danfoss / FC-102N200T4E54H2TGR7) Dilution Pump Inverter (Danfoss / FC- 102P55KT4P55H5TGC1) PLC Panel (ECOSPRAY TECHNOLOGIES / Main Panel 01) VDU Touchscreen 10” (SIEMENS / 6AV6643-0CD01-1AX1) - - - - - - - - - - Tests carried out:
EGCS Statutory Survey Report, doc. No. 2015CS013521. RINA job. ID. RS/2015/CS/01/3521 and RS/2015/CS/01/3520 and RS/2015/CS/01/3359
|
Limitation on the acceptance or use of the
product
In scheme B, according to MEPC.259(68), compliance with emission requirements is demonstrated by continuous exhaust gas monitoring.
EGCS acceptance and use to be within the terms and conditions of “Procedure for Compliance” at Para. 6 of PRMT-12426 approved on 27th November 2015 : “SOx Emissions Compliance Plan” – 14-130-APC-SECP.
Monitoring system is subject to periodic surveys by RINA according to MEPC.259(68).
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|