Reference documents
- WCBx-C Series Sewage treatment plant manufactured according to the WuHan Zhongzhou Environment Protection Equipment Co., Ltd technical specification and Drawings RINA Approved No. SHMC-10188.
- Laboratory accreditation certificate(No.CNAS L3061 & No. CNAS L1338).
- PONY Effluent Test Report No.:GDBYCCMG65175505Z(Sewage treatment plant) carried out by Pony Testing International Group (Shanghai) dated 17/02/2016.
- Environmental Test Report No.:CHKS2016-0161(CWC Sewage Treatment Plant Control Box) carried out by WuHan Environment and Reliability Test Center for Mechanical and Electrical Products of China Shipbuilding Industrial Corporation dated 8/04/2016.
- Function Test Report dated 26/01/2016.
Technical characteristics
- WCBx-C series sewage treatment plant are designed for biological operation based on an aerobic process.
WCBx-C Series | Hydraulic loading
(m3/day) | Organic loading
(kg/day) | Suitable number of persons |
WCBx-6C | 0.42 | 0.21 | 6 |
WCBx-10C | 0.70 | 0.35 | 10 |
WCBx-15C | 1.05 | 0.525 | 15 |
WCBx-20C | 1.40 | 0.70 | 20 |
WCBx-25C | 1.75 | 0.875 | 25 |
WCBx-30C | 2.10 | 1.05 | 30 |
WCBx-40C | 2.80 | 1.40 | 40 |
WCBx-50C | 3.50 | 1.75 | 50 |
WCBx-60C | 4.20 | 2.10 | 60 |
WCBx-80C | 5.60 | 2.80 | 80 |
WCBx-100C | 7.0 | 3.50 | 100 |
WCBx-150C | 10.5 | 5.25 | 150 |
WCBx-200C | 14 | 7.0 | 200 |
WCBx-300C | 21 | 10.5 | 300 |
WCBx-400C | 28 | 14 | 400 |
WCBx-500C | 35 | 17.5 | 500 |
WCBx-600C | 42 | 21 | 600 |
 | ATTACHMENT TO
CERTIFICATE No. MED207926WS
Page 2 of 5 |
- Discharge standard within the following limits:
| Thermotolerant Coliforms (geometric mean) | Less than 100 cells/100ml |
| 5-day Biochemical Oxygen Demand(BOD5) | Less than 25Qi/Qe mg/l |
| Chemical Oxygen Demand (COD) | Less than 125Qi/Qe mg/l |
| Total Suspended Solids (TSS) | Less than 35Qi/Qe mg/l |
| PH value | Between 6.0 and 8.5 |
| Total nitrogen | Less than 20Qi/Qe mg/l or at least 70 percent reduction |
| Total phosphorus | Less than 1.0Qi/Qe mg/l or at least 80 percent reduction |
Fields of application
- Each sewage treatment plant is to be supplied with it's manual for installation, use and maintenance.
- The installation on board is to be carried out in accordance with manufacturer's instructions.
- A copy of this EC type-examination certificate shall be carried on board any ship, equipped with the above discribed sewage treatment plant at all times.
- Limitations and conditions of operation are imposed as follows: Inclination less than 22.5 degrees and Viabration 2 to 13.2Hz with an amplitude of plus or minus 1mm and 13.2 to 80 Hz with an acceleration of plus or minus 0.7g.
Marking of product
A plate or durable label shall be placed on the sewage treatment plant with at least the following information:
- Manufacturer's name or logo
- Model and serial number
- Hydraulic loading
 | ATTACHMENT TO
CERTIFICATE No. MED207926WS
Page 3 of 5 |
Testing results
Test results and details of tests conducted on samples from the sewage treatment plant in accordance with resolution MEPC.227(64), as amended:
Sewage treatment plant, Type: ....................................................................................WCBx-20C
Manufactured by: ...............................................Wuhan Zhongzhou Environment Protection Equipment Co., Ltd.
Organization conducting the test: ...............................................................Pony Testing International Group
Designed hydraulic loading: ......................................1.4..........................................m³/day
Designed organic loading: ....................................0.7............................. kg/day BOD
Number of effluent samples tested: ...................................52....................................
Number of influent samples tested: ......................................52.................................
Total suspended solids influent quality: ............. ................1398.14..............................mg/l
Total nitrogen influent quality.................................93.53.............................mg/l as nitrogen
Total phosphorus influent quality.............................29.23.......................mg/l as phosphorus
BOD5 without nitrification influent quality: ...........................1015.39...............................mg/l
Maximum hydraulic loading: ....................................1.54................................... m³/day
Minimum hydraulic loading: .....................................0.42................................... m³/day
Average hydraulic loading (Qi): ................................1.4................................... m³/day
Effluent flow (Qe):..............................................1.4............................................ m³/day
Dilution compensation factor (Qi/Qe):..........................................0.91..............................
Geometric mean of total suspended solids: .............................5.4..........................mg/l
Geometric mean of the thermotolerant coliform count:...........20........ coliforms/100 ml
Geometric mean of BOD5 without nitrification: .........................4.81........................ mg/l
Geometric mean of COD: ........................21.57........................ mg/l
Geometric mean of total nitrogen .................................1.93............................mg/l* or %*
Geometric mean of total phosphorus..............................0.93..........................mg/l* or %*
Maximum pH: .............................7.82...................
Minimum pH: ................................6.94................
Type of disinfectant used: ........................................./.............................................
If Chlorine - residual Chlorine: No
Maximum:.............................................../...................................... mg/l
Minimum: .........................................../........................................... mg/l
Geometric Mean: ............................../............................................ mg/l
 | ATTACHMENT TO
CERTIFICATE No. MED207926WS
Page 4 of 5
|
Was the sewage treatment plant tested with:
Fresh water flushing? ................................./............................ Yes/No*
Salt water flushing? .................................../............................. Yes/No*
Fresh and salt water flushing? ......................Yes......................... Yes/No*
Grey water added? .....................Yes.................... Yes – proportion: ....1:2......... /No*
Was the sewage treatment plant tested against the environmental conditions specified in section 5.9 of resolution MEPC.227(64):
Temperature? ..................................Yes......................................... Yes/No*
Humidity?..............................................Yes.................................... Yes/No*
Inclination? ............................................Yes.................................... Yes/No*
Vibration? ................................................Yes.................................. Yes/No*
Reliability of Electrical and Electronic Equipment? ...........Yes......... Yes/No*
Limitations and the conditions of operation are imposed:
Salinity .........................................................................................<35g/L......................................
Temperature .............................................................................as per Part 3,MEPC.107(49)
Humidity ...................................................................................as per Part 3,MEPC.107(49)
Inclination .................................................................................as per Part 3,MEPC.107(49)
Vibration ...................................................................................as per Part 3,MEPC.107(49)
Results of other parameters tested ..................................../..............................