ATTACHMENT TO
|
CERTIFICATE No. MED080625VE/001
|
|
|
|
|
|
|
|
|
|
|
|
|
| Place of unit verification |
|
|
|
| Chioggia, ITALY,, |
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
23-1819-MAR-SC-100 [ME 1 sn XAAD613971 of IMO 1022641] 23-1819-MAR-SC-200 [ME 2 sn XAAD613974 of IMO 1022641] |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
PRMT-23250 approved on 11 April 2025 - exhaust gas cooling system PRMT-23251 approved on 11 April 2025 - main pumps PRMT-23252 approved on 11 April 2025 - desox DG#1-2 PRMT-23253 approved on 11 April 2025 - water analysis rack 1 PRMT-23254 approved on 11 April 2025 - water analysis rack 2+3 PRMT-23255 approved on 11 April 2025 - water analysis rack 4 approval letter PRMT/2025/69/RSPTZ
PPVT-48162 approved on 04 April 2025 - CN Visentini Record Book PPVT-48163 approved on 04 April 2025 - CN Visentini C236 ETM-B PPVT-48164 approved on 04 April 2025 - CN Visentini C236 OMM PPVT-48165 approved on 04 April 2025 - CN Visentini C236 SECP approval letter PPVT/2025/309/RSPTZ
--------------
ECO-ECG System DeSOx consisting of the verified components listed in "EGCS - TECHNICAL MANUAL – SCHEME B" approved with RINA No. PPVT-48163.
--------------
Tests carried out: EGCS Survey Report No. Visentini_C236_EGCS TEST REPORT relevant to tests carried out on 08/05/2025 Analysis Report relevant to tests No. VE25-00289_0 dated 23/05/2025.
|
Limitation on the acceptance or use of the
product
1-In scheme B, according to MEPC.340(77), compliance with emission requirements is demonstrated by continuous exhaust gas monitoring.
2-EGCS acceptance and use to be within the terms and conditions of “Procedure for Compliance” at Para. 6 of PPVT-48165 approved on 04 April 2025 - CN Visentini C236 SECP" .
3-Monitoring system is subject to periodic surveys by RINA according to MEPC.340(77).
4-This certificate is issued on the basis of test carried out while main engines running only on fuel with maximum content of sulfur not greater than 1,20% at 85% MCR.
5-This certificates annuls and replaces previously issued certicates n. MED065223VE and MED080625VE.
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|