Materials/Components for MX cable:
Halogen-free, Flame Retardant Shipboard and Yacht Power Cable
Rated voltage: 0.6/1 kV
Type: MX
Marking: ERİŞİM KABLO- type - n x s mm2 - 0.6 /1 kV - 90° C - IEC 60092-353, IEC 60332-3-22 Cat.A
Construction:
Conductor: Class-2 or Class-5, Stranded Multi Wire Copper or Tinned Multi Wire Copper
Insulation: Cross-linked HFFR compound
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228, IEC 60092-350-353-360, IEC 60332-3-22, IEC 61034-2, IEC 60754 1-2 , IEC 60684-2.
Conductor size:
Number of cores 1 - cross sectional area from 1.00 mm2 to 300 mm2
Materials/Components for MX-FR cable:
Halogen-free, Flame Retardant, Fire Resistant Shipboard and Yacht Power Cable
Rated voltage: 0.6/1 kV
Type: MX-FR
Marking: ERİŞİM KABLO- type - n x s mm2 - 0.6 /1 kV - 90° C - IEC 60092-353, IEC 60332-3-22 Cat.A, IEC 60331-21
Construction:
Conductor: Class-2 or Class-5, Stranded Multi Wire Copper or Tinned Multi Wire Copper
Insulation: Mica tape + cross-linked HFFR compound
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228, IEC 60092-350-353-360, IEC 60332-3-22, IEC 61034-2, IEC 60754 1-2 , IEC 60684-2, IEC 60331-21.
Conductor size:
Number of cores 1 - cross sectional area from 1.00 mm2 to 300 mm2
Materials/Components for MXH cable:
Halogen-free, Flame Retardant Shipboard and Yacht Power Cable
Rated voltage: 0.6/1 kV
Type: MXH
Marking: ERİŞİM KABLO- type - n x s mm2 - 0.6 /1 kV - 90° C - IEC 60092-353, IEC 60332-3-22 Cat.A
Construction:
Conductor: Class-2 or Class-5, Stranded Multi Wire Copper or Tinned Multi Wire Copper
Insulation: XLPE compound
Inner Covering: PES Tape or HFFR Compound
Sheath: HFFR Compound
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228, IEC 60092-350-353-360, IEC 60332-3-22, IEC 61034-2, IEC 60754 1-2 , IEC 60684-2.
Conductor size:
Number of cores 1 - cross sectional area from 1.00 mm2 to 300 mm2
Number of core 2 to 5 - cross sectional area from 1.00 mm2 to 300 mm2
Number of cores 5 to 24 - cross sectional area from 1.00 mm2 to 2.50 mm2
Materials/Components for MXH-FR cable:
Halogen-free, Flame Retardant Fire Resistant Shipboard and Yacht Power Cable
Rated voltage: 0.6/1 kV
Type: MXH-FR
Marking: ERİŞİM KABLO- type - n x s mm2 - 0.6 /1 kV - 90° C - IEC 60092-353, IEC 60332-3-22 Cat.A, IEC 60331-21
Construction:
Conductor: Class-2 or Class-5, Stranded Multi Wire Copper or Tinned Multi Wire Copper
Insulation: Mica Tape + XLPE compound
Inner Covering: PES Tape or HFFR Compound
Sheath: HFFR Compound
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228, IEC 60092-350-353-360, IEC 60332-3-22, IEC 61034-2, IEC 60754 1-2 , IEC 60684-2, IEC 60331-21.
Conductor size:
Number of cores 1 - cross sectional area from 1.00 mm2 to 300 mm2
Number of core 2 to 5 - cross sectional area from 1.00 mm2 to 300 mm2
Number of cores 5 to 24 - cross sectional area from 1.00 mm2 to 2.50 mm2
Materials/Components for MXCH cable:
Halogen-free, Flame Retardant, Screened Shipboard and Yacht Power Cable
Rated voltage: 0.6/1 kV
Type: MXCH
Marking: ERİŞİM KABLO- type - n x s mm2 - 0.6 /1 kV - 90° C - IEC 60092-353, IEC 60332-3-22 Cat.A
Construction:
Conductor: Class-2 or Class-5, Stranded Multi Wire Copper or Tinned Multi Wire Copper
Insulation: XLPE compound
Inner Covering: PES Tape or HFFR Compound
Screen: Multi Wire Copper Braiding or Tinned Multi Wire Copper Braiding
Sheath: HFFR Compound
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228, IEC 60092-350-353-360, IEC 60332-3-22, IEC 61034-2, IEC 60754 1-2 , IEC 60684-2.
Conductor size:
Number of cores 1 - cross sectional area from 1.00 mm2 to 300 mm2
Number of core 2 to 5 - cross sectional area from 1.00 mm2 to 300 mm2
Number of cores 5 to 24 - cross sectional area from 1.00 mm2 to 2.50 mm2
Materials/Components for MXCH-FR cable:
Halogen-free, Flame Retardant, Fire Resistant, Screened Shipboard and Yacht Power Cable
Rated voltage: 0.6/1 kV
Type: MXCH-FR
Marking: ERİŞİM KABLO- type - n x s mm2 - 0.6 /1 kV - 90° C - IEC 60092-353, IEC 60332-3-22 Cat.A, IEC60331-21
Construction:
Conductor: Class-2 or Class-5, Stranded Multi Wire Copper or Tinned Multi Wire Copper
Insulation: Mica Tape + XLPE compound
Inner Covering: PES Tape or HFFR Compound
Screen: Multi Wire Copper Braiding or Tinned Multi Wire Copper Braiding
Sheath: HFFR Compound
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228, IEC 60092-350-353-360, IEC 60332-3-22, IEC 61034-2, IEC 60754 1-2 , IEC 60684-2, IEC60331-21.
Conductor size:
Number of cores 1 - cross sectional area from 1.00 mm2 to 300 mm2
Number of core 2 to 5 - cross sectional area from 1.00 mm2 to 300 mm2
Number of cores 5 to 24 - cross sectional area from 1.00 mm2 to 2.50 mm2