General Description:
BorgWarner battery systems contain lithium ion cells, made typically of lithium ion nickel-manganese-cobalt oxide cell chemistry (Li-Ion NMC). Six-hundred of these cells are mounted to one module, whose temperature and voltages are measured by a monitoring unit, called CSC. Nine of these modules are combined in one tray. Each of these trays has connectors for coolant fluid, HV and LV and is operated by a controlling device, called BMU. If the battery system consists of multiple strings in parallel, a MSM is the final control unit. For customers, only the highest control unit in the software hierarchy is relevant, since this one coordinates all minor units.
| 148 |
Cell |
|
Material | Lithium-ion Nickel-Magnesia-Cobalt oxide (Li-Ion NMC) |
Capacity [Ah] | 18.2 |
Voltage [V] | 3.69 |
Temperature [°C] | -20 to 55 |
|
|
Module |
|
Type | UHE |
Quantity of cells | 20s x 30p |
|
|
Tray |
|
Type | AKASYSTEM 9 AKM 150 CYC |
Quantity of modules | 9 |
Capacity [Ah] | 148 |
Energy [kWh] | 98 |
Voltage [V] | 665 |
Power consumption [W] | 10 |
Life cycle | >4000 (at 80% DoD, 25°C) |
Degree of protection | IP67 to IP6k9k |
Weight [kg] | 598 |
The trays of AKASYSTEM 9 AKM 150 CYC battery system may be connected in parallel. The capacity of such connected trays is a multiplication of the rated capacity of one battery tray by their quantity.
Special Conditions for Safe Use:
The special conditions for safe use of the BorgWarner Battery Systems are to be considered based on the Risk Assessment that is required to be carried out in the design phase. In general, the arrangements mentioned on the following page are to be considered separately for each application:
- Ventilation/Exhaust, Structural Fire Protection, Fire and Gas Detection and Alarm System:
The battery room, where the BorgWarner Battery Systems are located, is to be provided with the above mentioned systems in the quantity or efficiency coming from the Risk Assessment created in the design phase and on the basis of the shipboard conditions and information from the system Manufacturer.
The toxic gases are generated in case of fire of the AKASystem Battery. Due to this reason, the ventilation system of battery compartment is to be independent and separate of the ventilation of other spaces and provided with local manual stop, still available in case of failure of the automatic and/or remote control system. The indication of ventilation running and of battery space ambient temperature is to be presented in a normally attended location.
TYPE APPROVAL CERTIFICATE
No. ELE081624XG
Enclosure - Page 2 of 2
BorgWarner Battery Systems - Cooling System: BorgWarner approves the use of Glysantin FC-G20 RM50. Please contact BorgWarner when use of another anti-freezing agent is intended. Do not pressurize the cooling system above 1.1 bar as this may lead to leakage of coolant into the battery system and consequently a short circuit of the battery modules and cells.
- Emergency Shutdown:
Battery system is to be disconnected in an emergency situation by implementing an emergency shutdown. The emergency shutdown is to be provided locally, from outside of the battery space, and from a normally attended location. It is to be arranged as a separate hardwired circuit and it is to be independent from the control system.
When battery system is used as storage of power dedicated to the propulsion system or as part of the main source of electrical power, the emergency shutdown is to be located on the bridge.
- Fire Suppression System:
The battery compartment, where the BorgWarner Battery Systems are located, is to be provided with the fire suppression systems in the quantity or efficiency coming from the Risk Assessment created in the design phase and on the basis of the shipboard conditions and information from the system Manufacturer. Due to the enclosure protection degree of IP67, the use of water based fire extinguishing systems is allowed. Automatic release of the fire suppression system is acceptable only for small, not accessible, battery spaces. When an automatic release of fire extinguishing media is accepted, its activation is to be confirmed by more than one sensor.
Reference Documents:
- Documentation:
1M001930,02,AKASYSTEM,9AKM,150,CYC,CUSTOMER;
3030316TEN0032 V1.2 System Description;
3M720061,01,HYDRAULICS,9MTRAY,ARAYMOND;
3030316TEN0001 User Manual;
3030316TEN0002 Safety Instruction;
3030316TEN0003,Overload,Protection;
3030316TEN0004,Parametersheet;
3030316TEN0008 Safety Description;
3030316TEN0026,Technical,Data,Sheet,v1.1;
3030316TEN0034,Gas,Compositon;
3030316TEN0036,Systemarchtiecture,Electricalschematic;
- Test Reports:
CTC: 1-4150,22-02-02-A; 1-5384,22-01-02-A;
Frauenhofer: 11-008163-1-Bericht,Vib,AKASOL,RCB,Reso,2022,sig1,unt; 11-008164-1-Bericht,Vib,AKASOL,Modul,Reso,2022,sig1,unt;
TZB: 2647,PBN,23032801E,mU;
Akasol: 3030316TEN0006,Cell,IEC62620; 3030316TEN0007,Module,IEC62620; 3030316TEN0019,System,IEC62620-Capacity-test; 3030316TEN0020,AKASYSTEM9AKM150CYC,Function,and,Safety,Test DNV sign 01; 3030316TEN0028,LeakageDetectionDocument; R256007; Report,SWE.6,AKA-SYSTEM,3-030316,2023,07,05-05,16,55,PM,DNV;
SGS: T3KZ0002;
Remarks:
The applicable documentation mentioned in reg. 1.3 of Rules for the Certification, Installation and Testing of Lithium Based Storage Batteries is to be submitted for each particular BorgWarner Battery Systems application. Special attention is to be paid to the requested Risk Assessment.
Place of Production
Borg Warner Akasol GmbH
Raiffeisenstraße 5A
63225 Langen, Germany | Akasol Inc.
1400 East 10 Mile Road, Suite 150
Hazel Park, Michigan 48030, USA | BorgWarner PDS (USA) Inc.
15545 Wells Highway, Seneca
SC 29678, USA |
|
|