Product information:
Product:
Monitoring and control system multifunctional display type UNS10191, UNS10192, UNS10193 and UNS10195.
Description:
The UNS10191-2-3-5 are programmable multifunctional display designed to be used for control, alarm, monitoring and safety functions of engines and auxiliary systems.
All versions are derived from the first panel UNS10195, from which they differ due to the screen size (respectively 4.3”, 5”, 7”) and the number of I/O lines available.
All panels are connected to the engine or auxiliary systems using a selection of conventional sensors (analogue, frequency, ON/OFF or output relay/transistor) or digital communication protocols (J1939, NMEA2000, Modbus).
Rating and main characteristics:
UNS10195:
Display | 7” TFT, resolution 800x480 LED backlight 800nits, sunlight readableOptical bonding, anti reflection treatmentCapacitive touchscreen |
Inputs: | 8 Analogue resistive inputs 0-300 ohm |
8 Analogue inputs resistive multi range (0-300 ohm, 0-100 Kohm, PT100, Pt1000) |
16 Analogue inputs 0-10Vdc / 4-20mA |
8 Thermocouple inputs (J or K type) |
6 Battery voltage inputs 0-36V |
3 Frequency inputs – min 5Vpp, 15 kHz (engine RPM, W Alternator, pick up) |
8 Digital inputs NPN |
Outputs | 8 Relay outputs (max 500 mA) including: | 1 d.o. for external buzzer control |
1 d.o. for cumulative alarm |
1 d.o. for fault alarm |
1 Auxiliary 9V output for sensors (100mA) |
Communication Ports | 4 Can Bus J1939 (N.1 NMEA2000 ready) |
1 RS485 |
1 RS232 |
1 NMEA 0183 input |
1 USB OTG |
1 Ethernet |
Power Supply | Main power supply | 12-24V |
Auxiliary power supply | 12-24V |
Environmental | Operating range : -20 + 70°C, Protection : IP 56 on front |
UNS10191:
Display | 4.3” TFT , resolution 480x272
LED backlight 700nits, sunlight readable
Resistive touchscreen |
Inputs / Outputs | 4 Analogue resistive inputs 0-300 ohm or
4 Digital outputs NPN (max 150mA, 500mA cumulative))
|
2 Analogue voltage inputs 0-32V or
2 Digital outputs PNP (max 150mA, 500mA cumulative)
|
2 Digital outputs PNP |
1 Analogue voltage input 0-32Vor Frequency input, min 5Vpp 15 kHz (W Alternator, pick up) |
1 Analogue voltage input 0-3V (amperometric transformer TA) |
Communication Ports | 1 Can Bus J1939 |
Power Supply | Main power supply 12-24V |
Environmental | Operating range : -20 + 70°C, Protection : IP x5 on front |
UNS10192 – UNS10193:
Display | UNS10192 : 5” TFT , resolution 480x272, 900nits
UNS10193 : 7” TFT , resolution 800x480, 800nits
Sunlight readable, optical bonding
Capacitive touchscreen |
Inputs / Outputs | 4 Analogue resistive inputs 0-300 ohm (0-32V on request) |
4 Analogue resistive inputs 0-32V (0-300ohm on request) |
4 Digital inputs NPNor
4 Digital outputs NPN (max 150mA, 500mA cumulative)
|
1 Digital input NPNor 1 Frequency input, min 5Vpp 15 kHz (W Alternator, pick up) |
1 Frequency input, min 5Vpp 15 kHz (W Alternator, pick up) |
Communication Ports | 2 Can Bus J1939 (N.1 NMEA2000 ready) |
1 RS232 (RS 485 optional) |
1 NMEA 0183 input |
1 USB OTG |
1 Ethernet |
Power Supply | Main power supply 12-24V |
Environmental | Operating range : -20 + 70°C, Protection : IP x5 on front |
Datasheet and reference documents:
For UNS10191 (4.3” display):
D191113 | Datasheet | 09/01/2024 |
M201110 | User manual | 09/03/2021 |
For UNS10192 (5” display) :
D170522 | Datasheet | 20/01/2023 |
M180427 | User manual | 28/03/2023 |
For UNS10193 (7” display):
D190410 | Datasheet | 06/08/2024 |
M200203 | User manual | 29/10/2020 |
For UNS10195 (7” display):
D150903 | Datasheet, standard version | 03/05/2023 |
D150904 | Datasheet, M12 CAN only version | 20/12/2021 |
M151106 | User manual | 05/12/2017 |
Test Reports:
UNS1019x Test Plan – rev 241213
Report 16B249F (UNS10195, 15/12/2017)
Report 1117_2024, (4/12/2024)
Report RPT12110001 (UNS10195, 12/12/2024)
Report RPT12110011 (UNS10191, 12/12/2024)
Report RPT12110012 (UNS10192, 12/12/2024)
Report RPT12110013 (UNS10193, 12/12/2024)
Remarks:
All devices are suitable to be installed also on the open deck of a ship. Special setups are available for engine protection (safety) using analogue inputs to perform line monitoring for safety measurements and digital output for engine automatic stop.
Validity of this certificate is subject to satisfactory outcome of yearly audit as per RINA " Rules for Testing and Certification of Marine Materials and Equipment".