MED511525CS!016ENG- -  -  N- B0 GRP WALL WET UNIT WITH PIPE PENETRATION -N- S- S- -09/02/2026- Marine Equipment- - SN- S- - N-  - 2,370,495B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED511525CS/016- N-Dec 2, 20302370495
 
Form
  Marine Equipment(TO)
Certification N. MED511525CS/016 - (ENG)
Certificate date 09/02/2026
Type Protezione antincendio
Product Penetrations through "B" Class divisions: (b) pipe, duct, trunk, etc. penetrations
Item Nº MED/3.27b

Model or Denomin.
Items
B0 GRP WALL WET UNIT WITH PIPE PENETRATION
Applicant MARINE INTERIORS S.P.A.
Place of requester VIA GENOVA 1  %  34121 Trieste (TS)  % ITALY
Tel. N.,Fax, Email ---, ---, marco.varriale@fincantieri.it
Directive (EU) 2025/1533
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents IMO Res. MSC.1/Circ.1655.,SOLAS 74 Reg. II-2/9
Expire date 02/12/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED511525CS/016

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.27b
Description Penetrations through "B" Class divisions: (b) pipe, duct, trunk, etc. penetrations
Type B0 GRP WALL WET UNIT WITH PIPE PENETRATION
Applicant MARINE INTERIORS S.P.A.
VIA GENOVA 1,34121 Trieste (TS),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards IMO Res. MSC.1/Circ.1655.; SOLAS 74 Reg. II-2/9
Issued in Genoa on
This Certificate is valid until
February 9, 2026
December 2, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED511525CS/016
Page 1 of 2

Product description



B0 bulkhead Certified No. MED511525CS/014, equipped with following accessories pipes:

· No.1 multilayer pipe having diameter 20 mm thickness 2.5 mm placed at 990 mm from the bottom of the bulkhead, passing through one horizontal stiffener of the bulkhead, by a pipe transit composed by a full threaded brass niples 3/4” thickness 3.5mm, brass nut with flange 3/4” and on the edges, two 3/4”F adapter for multilayer pipe diameter 20mm;

· No.1 multilayer pipe having diameter 16 mm thickness 2.25 mm placed at 650 mm from the bottom of the bulkhead, passing through one horizontal stiffener of the bulkhead, by a pipe transit composed by a full threaded brass niples 1/2” thickness 3.5mm, brass nut with flange 1/2” and on the edges, two 1/2”F adapter for multilayer pipe diameter 16mm;

· No.1 copper pipe having diameters 15 mm thickness 1 mm placed at 990 mm from the bottom of the bulkhead, passing through one horizontal stiffener of the bulkhead, by a pipe transit composed by a full threaded brass niples 1/2” thickness 3.5mm, brass nut with flange 1/2” and on the edges, two brass nuts 1/2”;

· No.1 copper pipe having diameter 22 mm thickness 1 mm placed at 650 mm from the bottom of the bulkhead, passing through one horizontal stiffener of the bulkhead, by a pipe transit composed by a full threaded brass niples 3/4” thickness 3.5mm, brass nut with flange 3/4” and on the edges, two brass nuts 3/4”;

· No.1 brass pipe having diameter 32 mm thickness 0.6 mm placed at 990 mm from the bottom of the bulkhead, passing through one horizontal stiffener of the bulkhead, by a pipe transit composed by a full threaded brass niples 1 1/4” thickness 3.5mm, brass nut with flange 1 1/4” and on the edges, two brass nuts 1 1/4”;

· No. 1 stainless steel pipe having diameter 50 mm thickness 1 mm, placed at 125 mm from the bottom of the bulkhead, passing through the coaming of the bulkhead by a hole having diameter 120 mm. The pipe transit is carried out by two steel shaped sheet 150x110 mm thickness 1.5 mm, fixed on the coaming by no. 6 steel self-drilling screws.

· No. 1 stainless steel pipe having diameter 50 mm (#) thickness 1 mm, placed at 125 mm (#) from the bottom of the bulkhead, passing through the coaming of the bulkhead by a hole having diameter 120 mm. The pipe transit is carried out by two steel shaped sheet 150x110 mm thickness 1.5 mm, fixed on the coaming by no. 6 steel self-drilling screws. On the exposed side, the pipe is insulated for 10x10 mm by
fire retardant sealing type “SIKE Firesil M arine” Certified for low frame spread characteristics;
Field of application

Fire resisting B-0 Class bulkhead, for general applications, fitted with pipe penetrations.
Reference documents
Marine Interiors Cabins drawings No. +24PC00497 rev. 02 and +24PC00498 rev. 02 dated 04/09/2024.
Tests carried out
Tests as per RINA Test Laboratory reports No. 2024CS012569/7 issued on 25 November 2024 and No
2024CS012569/10 issued on the 05 December 2024 according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED511525CS/016
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella