Bulkhead having maximum dimension 1685 mm width, 2910 mm height and thick of 25 mm. Bulkhead composed of two side by side bulkheads installed with, in between, a minimum air gap of 100 mm. Each bulkheads, consisting of maximum three panels having maximum width of 540 mm and maximum height of 2910 mm; the panels are composed of two steel sheets, having thickness of 0.6 mm each and with inside one layer of mineral wool Izocam Marine Firebattes 110 recognized as not combustible material as per FTP Code 2010. The mineral wool is glued to the steel sheets by means of 250 g/m2 of glue named Sika Force 710 L100. The panel joints, on the exposed side, consist of “C”shaped steel clip profiles having dimensions of 10x8x10 mm and thickness of 0.6 mm. The bulkhead is fitted on the upper side with a "U" shaped steel profile with a thickness of 1.2 mm and dimensions of 25x25 mm and on the bottom with a “U” shaped steel profile with a thickness of 1.2 mm having dimensions of 25x25 mm and on the side with a "U" shaped steel profile with a thickness of 0.6 mm having dimensions of 25x25 mm. The panels, on the exposed side, are fixed by means of screws having diametre of 4 mm, on fixin installation profile having pitch horizontally 200 mm and vertically 300 mm.
Field of application Fire resistant B-0 Class bulkhead for general application.
Due to the fact that this B class bulkhead has been tested from only one side and has been designed to be installed with the untested side adjacent to the untested side of another B class bulkhead, this EC type-examination certificate is valid only if these conditions are respected when installed on board ensuring that the level of protection indicated in the relevant fire integrity tables included in SOLAS Chapter II-2/Reg.9.2 Thermal and Structural Boundaries is always fulfilled.
Reference document Mercan Panel drawing No. MRN-LWP-M1 dated 29/01/2024 enclosed on the test report No. RFTR24044-REV1 issued on 06/11/2024 and Mercan Panel drawing No. MRN-LWP-M1 rev.0 dated 16/01/2025 identified by N0. 2025CS01162/2.
Tests carried out Tests as per Efectis laboratory test report No. RFTR24044-REV1 issued on 06/11/2024 according to IMO Res. MSC.307(88)-(2010 FTP Code), as amended. |