ELE052224XG!001ENG- -  -  N- XTVR Series -N- S- S- -03/04/2024- Prodotti Elettrici- - SN- N- Giuseppe Russo- N-  - 1,051,913Giuseppe RussoBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE052224XG/001- N-Apr 2, 20291051913
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE052224XG/001 - (ENG)
Certificate date 03/04/2024
Type Impianti Elettrici
Product ELECTRIC TRACE HEATING SYSTEM

Model or Denomin.
Items
XTVR Series
Applicant nVent Thermal Belgium - nVent Thermal Belgium NV
Place of requester Romeinse straat 14  %  3001 Leuven  % BELGIUM
Tel. N.,Fax, Email ---, ---, Gerry.DeBlick@nVent.com
Standards RINA-Rules for the Classifications of Ships.
Expire date 02/04/2029
Head Office HAMBURG
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE052224XG/001
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC TRACE HEATING SYSTEM
Type XTVR Series
Applicant nVent Thermal Belgium - nVent Thermal Belgium NV
Romeinse straat 14
3001 Leuven
BELGIUM
Reference standards RINA-Rules for the Classifications of Ships.
  

 
 
   .   This Certificate is valid until April 2, 2029
_________________________________
RINA Services S.p.A.
Giuseppe Russo
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE052224XG/001
Enclosure - Page 1 of 2
XTVR Series
General description:

The XTVR Range of Trace Heating Units is of the parallel circuit self-regulating type, rated at 190 up to 277 V
with power output up to 64W/m. The units have a maximum self-limiting temperature of 240°C.

Each trace heating units comprises:
- The active heating cable
- An end seal for terminating the remote end of the unit
- A cable gland for connecting the powered end of the unit to a suitable terminal enclosure, or alternative integrated power connection system.
The active heating cable comprises two stranded copper conductors separated by a fluoropolymer spacer around which are wound,
in a spiral, a number of carbon loaded polymer fibres which form the active part of the heating cable.
An extruded layer of fluoropolymer covers the fibres and serves to insulate the copper conductors from a tinned copper braid
which covers the basic heater.
A protective anti corrosion fluoropolymer sheath may be extruded over the braid.
In this arrangements the unit is designated the XTVR2-CT Range of Trace Heating Units.

The declared maximum withstand temperature for the range is 250°C and the minimum installation temperature is -60°C.


Cable Accessories:

END SEALS
The end seals for terminating the remote end of the unit may be the following types:
-Type E-100-L-x or E-100-x, which are mechanical end seal incorporating an end cap which is filled with silicone grease sealant,
-Type E-40, which comprises heat shrink sleeves lined with hot melt adhesive
-Type E-150 mechnical end seals

SPLICES AND JOINT
The following splicing and jointing arrangement are provided
- A Raychem Type S-40 heat shrink splice kit for connecting lengths of active heating cable.
- A Raychem T-100 tee connection system, for connecting up to three heater cables
- Type S-150 mechanical splice kit

POWER CONNECTION
Power connection may be achieved by the following means:
-Types C25-21. The kits may use a molded silicone rubber
core seal to insulate the bus wires with silicone grease in a molded cavity to seal the end of the heating cable. In this arrangement
the kit Type C25-100
-C25-100-Metal-NP, C25-100-Metal-SS, C3/4-100-Metal, C3/4-100-Metal-NP, C3/4-100-Metal-SS and C75-100-A, which incorporate a type E8XF metallic cable gland
-Type C-150 power connector
-Type JBS-100 power connection system for a single heater cable
-Type JBM-100 power connection system for multiple heater cables
-Type JBU-100 power connection system
-Type CCON connection kit











TYPE APPROVAL CERTIFICATE
No. ELE052224XG/001
Enclosure - Page 2 of 2
XTV Series

Special Conditions for Safe Use:

The following limiting temperatures for the end seals , splices and power connections shall not be exceeded:

250°C for JBU-100 ; 200°C for E-40 and S-40 ; 151°C for the E-100, E-100-L and JBS-100;
155°C for the JBM-100 and T100; 110°C for the GHG 960 923 P … cable glands and C25-100 and C25-100 connection kits.
180° for the type E8XF cable gland; 150°C for the E-150, S-150 and C-150 ; 110°C for the CCON

The E-100, E-100-L, JBM-100, JBS-100 and T-100 have limiting temperatures based on internal component in these
accessories. When located on pipe or other work piece surface, a maximum pipe temperature of 215°C will not cause
the limiting temperatures of 151°C or 155°C to be exceeded.

The end seal, splices and power connections have the following associated minimum ambient temperatures:

-60°C for the E-40, S-40 and CCON ;
-55°C for the E-100, , E-150, S-150, C-150, JBS-100, JBU-100 and JBM-100 _
-40°C for the JBS-100-L, JBM-100-L, T100, JBU-100-L, E-100-L
-55°C for the GHG 960 923 P… cable gland with silicon rubber seals and C25-100 and C25-21 connection kits
-60°C for the type E8XF cable gland

Minimum bending radius at -60° C ≤ T ≤ -20° C is 51mm for the type XTVR units.


Thermal output rating: 13 to 66 W/m at 10° C


Reference documents:

- ATEX Certificate

Certification Authority: SGS Fimko Oy, Takomotie 8, FI-00380 Helsinki, Finland

Certificates: SGS20ATEX0049X - Issue3

Marking:
II 2 GD Ex 60079-30-1 eb IIC T* Gb Ex 60079-30-1 eb mb IIC T* Gb or
Ex 60079-30-1 tb IIIC T**°C Db Ex 60079-30-1 mb tb IIIC T**°C Db
(* .** See details in ATEX Certificate Schedules)

Safety Standard:
EN60079-0: 2018 ; EN60079-7:2015+A1:2018 ; EN60079-30-1:2017 ; EN60079-31:2014


- Data Sheet: EN – Raychem-DS-EU2174-XTVR

Remarks:
The Information listed in the present certificate are partial information based on the Baseefa Certificates.
The component listed in this Certificate are to be used / installed according to the manufacturer instructions:
Special conditions for safe use and installation to be in accordance with the above referenced ATEX Certificates.

The certificate supersedes previous RINA certificate No. ELE065119XG/001.

HAMBURG April 3, 2024