1. Production Description:
Cable Trays types MY-B/CT series used for Marine & Offshore Installation. 'MY' means the vendor MUYI, "B" means the material of Fibre Reinforced Plastics(FRP), "CT" means Cable Tray, "50/70/100/150" means the height of guide is 50mm, "L" means the cable tray is ladder type.
Code | Material | Specification description(mm) | Safe Working Load(kg/m) |
| MY-B/CT-50L-100W | FRP | Width 100, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-150W | FRP | Width 150, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-300W | FRP | Width 300, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-450W | FRP | Width 450, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-600W | FRP | Width 600, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-750W | FRP | Width 750, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-900W | FRP | Width 900, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-50L-1000W | FRP | Width 1000, Length 3000/6000, Height 50 | 150 |
| MY-B/CT-70L-100W | FRP | Width 100, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-150W | FRP | Width 150, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-300W | FRP | Width 300, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-450W | FRP | Width 450, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-600W | FRP | Width 600, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-750W | FRP | Width 750, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-900W | FRP | Width 900, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-70L-1000W | FRP | Width 1000, Length 3000/6000, Height 70 | 160 |
| MY-B/CT-100L-100W | FRP | Width 100, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-150W | FRP | Width 150, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-300W | FRP | Width 300, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-450W | FRP | Width 450, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-600W | FRP | Width 600, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-750W | FRP | Width 750, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-900W | FRP | Width 900, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-100L-1000W | FRP | Width 1000, Length 3000/6000, Height 100 | 200 |
| MY-B/CT-150L-100W | FRP | Width 100, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-150W | FRP | Width 150, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-300W | FRP | Width 300, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-450W | FRP | Width 450, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-600W | FRP | Width 600, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-750W | FRP | Width 750, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-900W | FRP | Width 900, Length 3000/6000, Height 150 | 260 |
| MY-B/CT-150L-1000W | FRP | Width 1000, Length 3000/6000, Height 150 | 260 |
TYPE APPROVAL CERTIFICATE
NO. ELE576825WS
Enclosure - Page 2 of 2 MY-B/CT-50L series
MY-B/CT-70L series
MY-B/CT-100L series
MY-B/CT-150L series
2. Reference documents:
+ Application form, Filed by RINA with drawing No. SHEL/28991.
+ Latest products Specification, Filed by RINA with drawing No. SHEL/28992.
+ Manufacturer's general information, Filed by RINA with drawing No. SHEL/28993.
+ Asbestos-free Declaration, Filed by RINA with drawing No. SHEL/28994.
+ Type test Outline, Filed by RINA with drawing No. SHEL/28995.
+ Test reports, Filed by RINA with drawing No. SHEL/28996~SHEL/29003.
+ Routine test Report signed by Surveyor, Filed by RINA with drawing No. SHEL/29004.
+ Narrative Report, Filed by RINA with drawing No. SHEL/29005.
+ Lab. qualification and test scope document, Filed by RINA with drawing No. SHEL/29006.
3. Remarks:
+ The product is subject to the compliance with RINA Rules and other Standards mentioned on Certificate.
+ Prototype Design Assessment certifies that a representative sample of the product has been found to meet the applicable design criteria
+ Any modification or change shall not be valid until approval, resulted from due assessment, is granted by RINA.
+ Environment temperature classification : from -40℃ to +90℃.
+ The installation of the cable trays is to be compliance with manufacturer's standard and RINA Rules Pt C, Ch 2, Sec10.
|
|