Materials/Components
Halogen free, low smoke, shipboard power and control cables, flame retardant type, with/without (EMC) screen.
Rated voltage: 0.6/1 kV
Type: FLAMEBLOCKER NKOXS 0.6/1 kV
FLAMEBLOCKER NKOXSekw 0.6/1 kV
FLAMEBLOCKER NKOXSekw EMC 0.6/1 kV
Marking: TF KABLE 3 - type - n X size - 0.6/1 kV - IEC 60332-3 cat. A - year
Construction:
a.) conductor:
- circular stranded bare or tinned copper class 2: 1 to 6 mm2,
- circular compacted stranded bare or tinned copper class 2: 10 to 300 mm2,
- circular stranded bare or tinned copper class 5,
- sector shaped 35 to 300 mm2,
acc. to IEC 60092-350 and IEC 60228;
b.) insulation:
- cross-sections ≤ 35 mm2: cross-linked polyethylene XLPE, acc. to IEC 60092-360,
- cross-sections > 35 mm2: cross-linked polyolefin compound HF 90, acc. to IEC 60092-360;
c.) inner covering: bedding tape or/and extruded layer special flame-retardant, halogen-free compound;
d.) screen:
- NKOXS: none,
- NKOXSekw: copper wire braiding,
- NKOXSekw EMC: copper/polyester tape (coverage 100%) and copper wire braid,
acc. to IEC 60092-350;
e.) sheath: halogen free thermoplastic compound type SHF 1 acc. to IEC 60092-360;
f.) max. conductor temperature: 90°C;
g.) min. installation temperature: -15°C;
h.) conductor sizes: as per cable catalogue cards.
International standards:
IEC 60092-350 (Ed. 5.0: 2020), IEC 60092-360 (Ed. 2.0: 2021), IEC 60092-353 (Ed. 5.0: 2024),
IEC 60332-1-2 (Ed. 2.0: 2025), IEC 60332-3-22 Cat. A (Ed. 2.0: 2018), IEC 60228 (Ed. 4.0: 2023),
IEC 60754-1 (Ed. 3.0: 2011 /AMD1:2019), IEC 60754-2 (Ed. 2.0: 2011 /AMD1:2019),
IEC 61034-1 (Ed. 3.0: 2005 /AMD2:2019), IEC 61034-2 (Ed. 3.0: 2005 /AMD2:2019).
Technical specifications:
- NKOXS 0,6/1kV: MK-24-02-2017,
- NKOXSekw (EMC) 0,6/1kV: MK-26-01-2017.
Additional manufacturer:
TELE-FONIKA KABLE S.A
Ul. H. Cegielskiego 1
32-400 Myslenice
Poland |
|