Materials/Components
Shipboard power cables, flame retardant, fire resistant, halogen free with low smoke emission, for ships and off-shore units installation.
Rated voltage: 60/250 V
Type: FMGCH-FFR
Marking: UNTEL DIN 89159 IEC 60092-376 FMGCH-FFR n x s mm2 250 V IEC 60332/3A IEC 60331
Construction:
conductor: stranded copper wire class 2 or 5, tinned on request
mica tape on the conductor
insulation: HF-EPR
laid up: cores laid up in pairs
separating foil
screen: plain copper braid wires, tinned on request
separating foil
sheath: SHF1
Max. conductor temperature: 90°C.
In accordance to rules DIN 89159; IEC 60228; IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60331-21; IEC 60332-1-2; IEC 60332-3-22.
Conductor size:
number of cores x pairs 1,2,4,7,10,14,19,24 - cross sectional area 0.5, 0.75, 1, 1.5 mm2
Technical specification: data sheet N. FR 70-052 Rev1 dated 01/07/2011.