Single leaf hinged vertical door with maximum clear opening size of 4708 x 2008 mm (WxH), installed on a standard aluminum bulkhead. The tested leaf, having maximum dimensions of 1766x1866 mm (WxH) and thickness of 163 mm is composed of one ballistic protection steel plate type “Ramor 500”, 6 mm thick. The leaf is fitted with two vertical bulbs stiffeners, having height of 80 mm and thickness of 5 mm, welded to the steel plate with pitch range from 400 mm up to 427 mm and in the middle it is provided a stiffener “C” shaped composed by two steal plate having an height of 150 mm and thick of 4 mm and by a steel plate (flitch) having a width of 190 mm and thick 8 mm. The perimeter of the leaf consists of an “L” steel shaped profile having an height of 157 mm, width of 104 mm and thick 6 mm with steel plates of stiffeners with dimensions 150 mm x 180 mm (HxW), having a pitch of 400 mm. The leaf, having maximum clear opening of 1708x1808 mm (WxH) is fitted with one hinge, the leaf having ranging clear opening dimension from 1708x1808 mm (WxH) up to 4708 x 2008 mm (WxH) is fitted with two hinges. The leaf is provided with a lever closing device fitted on the unexposed side to the fire, that acts on three points in lower side, one on each vertical side and one on the upper side. The steel edge bended of the leaf, having dimensions 42x50 mm (LxH), is provided of a calcium magnesium silicate fiber gasket 40x40 mm, type HTS item Vetraltemp 1000°C; the steel edge bended of the frame, having dimensions 41x36 mm (LxH), is provided of a closed-cells silicone gasket 40x30 mm, type Technical Rubber item B.1633; on both sides of the above mentioned labyrinth is provided a stripe of intumescent material 30x5 mm Marvon Tecnoflame. The door frame is composed of one ballistic protection steel plate type “Ramor 500”, 6 mm thick and width 346 mm stiffened by two side by side rectangular steel profiles 120x60 mm thick 6 mm (outer side) and 100x60 mm thick 6 mm (inner side); in way of the hinge the steel plate is stiffened by two overlapped rectangular steel profiles 100x60 mm thick 6 mm. The door frame is bolted to the bulkhead by bolts M12 having a pitch of 250 mm. The leaf and the frame are insulated, on the exposed side to the fire, with one layer of mineral wool thick 70 mm and density 66 kg/m3 type Isover Ultimate U SeaProtect. The mineral wool is fixed to the steel plate by means of steel pins and washers welded with a pitch range from 250 mm up to 300 mm.
The door and frame have been treated with Chugoku-Boat Idromarina Primer, an acrylic primer, applied at a rate of 0.28 kg/m².Field of application Fire resistant A-60 Class single leaf hinged door.
The tested door is also in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the tested door may be increased of 15% provided that the surface area is not increased of more than 10%.
For doors exceeding 50% in surface area with respect to the tested doors, the installation on board has to be submitted, on a case-by-case basis, also to a full analysis based on Solas Regulation II-2/17 (alternative design).
In case of doors in compliance to the "Agreement between the EEA EFTA States and the United States of America", the present certificate is valid at the following conditions:
- doors without windows;
- maximum door size tested;
- door used with a fire tested frame design.Reference documents Ascheo drawing No. "D089700" Rev. C dated 14/05/2026 enclosed on Test Report N.2026CS011849 dated 26/06/2026; Ascheo drawing No. "D089701" Rev. A dated 03/03/2026 enclosed on Test Report N.2026CS011849 dated 26/06/2026; Ascheo drawing No. "D089751" Rev. A dated 03/03/2026 enclosed on Test Report N.2026CS011849 dated 26/06/2026; Ascheo drawing No. "D089200" Rev. B dated 14/04/2026; Ascheo drawing No. "D089201" Rev. A dated 20/12/2024 and Ascheo drawing No. "D089251" Rev. A dated 03/12/2024
Rina document N. 2026-002-MITHP Rev. 0 dated 26/06/2026.Tests carried out Tests as per RINA Test Laboratory Report No. 2026CS011849 dated 26/06/2026 issued according to IMO 2010 FTP Code Part 3.Increased dimensions verified with Thermal-Mechanical analysis as per RINA Technical Report No. 2026-002-MITHP Rev. 0 dated 26/06/2026 |