1.1 Technical Specification SHMC31680, 1.2 Onboard Monitoring Manual (OMM) SHMC31728, 1.3 Technical Manual, Scheme B (ETM-B) SHMC31682, 1.4 SOx Emission Compliance Plan, Scheme B (SECP) SHMC31681, 1.5 EGC Record Book SHMC31684, 1.6 Electrical Drawing SHMC20997, 1.7 General arrangement of Scrubber SHMC28536.
2. The EGC unit from Bluesoul, often referred to as a scrubber, is based on the wet scrubbing technology. This particular system uses the surrounding seawater as wash water, which is discharged once through, that it is described as an open system. The entire monitoring system is designed according to MARPOL Annex VI, NOx technical code 2008 chapter 5 and its Appendix III and according to section 6 of the Guidelines. A continuous stream of exhaust gas is extracted from the funnel after the EGC unit. The sample probe draws in the sample stream which is led to the conditioning cabinet via a heated sample line, where it is filtered and dehumidified before it is sent to the gas analyzer. The analyzer measures the SO2 and CO2 from where the Emission Ratio (ER) can be calculated. The measurements are logged every 80 seconds.
3. Completed Tests on board were carried out from 20241223 to 20241224 during sea trial in accordance with IMO Res. MEPC.340(77) & approved documents, and relevant testing reports/ records are listed as below: 1. Commissioning test report; 2. Bunker Delivery Notes and laboratory analysis report; 3. RINA type approval certificate for Emission Monitoring system; 4. RINA certificate for scrubber control panel; 5. Calibration protocols/certificates of CEMS and water monitoring sensors; 6. Span gas analysis certificate; 7. RINA Certificate for the body of Exhaust Gas Cleaning System; 8. RINA Certificate for Electric Motors and Feed pumps; 9. Wash water sample nitrate analyses report from laboratory, and Certification for laboratory.
|