MED122524WS!002ENG- -  -  N- CKJ Series -N- S- S- -24/12/2025- Marine Equipment- - SN- S- - N-  - 326,167B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED122524WS/002- N-Dec 23, 2030326167
 
Form
  Marine Equipment(TO)
Certification N. MED122524WS/002 - (ENG)
Certificate date 24/12/2025
Type Protezione antincendio
Product Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: (i) Cables
Item Nº MED/3.51i

Model or Denomin.
Items
CKJ Series
Applicant YANGZHOU GUANGMING CABLE CO., LTD.
Place of requester Lingtang Town, North Suburbs  %  225652 Yangzhou (Jiangsu)  % CHINA
Tel. N.,Fax, Email 15190425811,0514-80952312, yzqm01@126.com
Directive (EU) 2025/1533
Standards IEC 60092-350,IEC 60092-360,IEC 60092-376:2017,IEC 60331-1:2018,IEC 60331-2:2018,IEC 60332-1-2:2004 incl.A1:2015,A11:2016 and A12:2020,IEC 60533:2015,IEC 60754-1,IEC 60754-2,IEC 61034-1,IEC 61034-2
Reference Documents SOLAS 74 Reg.II-2/7, SOLAS 74 Reg.X/3, IMO Res.MSC.36(63)-(1994 HSC Code) 7, IMO Res.MSC.97(73)-(2000 HSC Code) 7, IMO Res.MSC.98(73)-(FSS Code) 9, IMO Res.MSC.391(95)-(IGF Code) 11, IMO MSC/Circ.1242.
Expire date 23/12/2030
Responsible Office SHANGHAI
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Qiang Sun S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED122524WS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.51i
Description Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: (i) Cables
Type CKJ Series
Applicant YANGZHOU GUANGMING CABLE CO., LTD.
Lingtang Town, North Suburbs,225652 Yangzhou (Jiangsu),CHINA
Testing standards IEC 60092-350,IEC 60092-360,IEC 60092-376:2017,IEC 60331-1:2018,IEC 60331-2:2018,IEC 60332-1-2:2004 incl.A1:2015,A11:2016 and A12:2020,IEC 60533:2015,IEC 60754-1,IEC 60754-2,IEC 61034-1,IEC 61034-2
Reference standards SOLAS 74 Reg.II-2/7, SOLAS 74 Reg.X/3, IMO Res.MSC.36(63)-(1994 HSC Code) 7, IMO Res.MSC.97(73)-(2000 HSC Code) 7, IMO Res.MSC.98(73)-(FSS Code) 9, IMO Res.MSC.391(95)-(IGF Code) 11, IMO MSC/Circ.1242.
Issued in SHANGHAI on
This Certificate is valid until
December 24, 2025
December 23, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Qiang Sun
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED122524WS/002
Page 1 of 3

Product Description
150/250V shipboard control cables having following rating:
Type Designation
Number of
Pairs/Triples
Nominal Conductor
Cross-sectional Area
[mm2]
Maximum rated
Conductor Temperature [0C]
Fire Property
CKJ85/86/95/96
CKJP85/86/95/96
CKJPJ85/95

CKJPF86/96
CKJPJP85/95
CKJPFP86/96
/(SC/NC)
2~37
Core two-wire group:0.75~2.5
90
Fire-resisting
- IEC 60332-1
- IEC 60331-1
- IEC 60331-2
Note: + “Number of Core” is selected from the following series of core number:
2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37.
+“Nominal Conductor Cross-sectional Area” is selected from the following series of core number:
0.75, 1.0, 1.5, 2.5 mm2.
+ Conductor: Tinned copper conductors.
+ Other properties’ suffix:
CK: Shipboard control cable.
J : XLPE
P : Aluminum foil & tinned copper drain wire
XLPE: Cross-linked polyethylene
PJ : Thermoset polyolefin (SHF2).
PF: Thermoplastic polyolefin (SHF1).
8 : Tinned copper wire braided.
9 : Galvanized steel wire braided.
5 : Thermoset polyolefin (SHF2).
6 : Thermoplastic polyolefin (SHF1).
SC: Bunched Flame Retardant, Low Smoke, Halogen-Free
NSC: Low smoke, halogen free and low toxicity, fire resistance, flame retardant for bunched wires or cables.






 



ATTACHMENT TO
CERTIFICATE No. MED122524WS/002
Page 2 of 3
Application

The control and instrumentation cables are approved used for fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces in marine and offshore field.

Design Assessment

The design assessment is based on SOLAS 74 Reg. II-2/7, IMO Res. IMO Res. MSC.36(63)-(1994 HSC Code) 7, IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO Res. MSC.98(73)-(FSS Code) 9, IMO Res. MSC.391(95)-(IGF Code) 11, IMO MSC.1/Circ.1242.

Cable installation in ships, as applicable, comply with IEC standards: IEC 60092-504:2016, IEC 60533:2015. IEC 60092-376:2017, IEC 60331-1:2018 or IEC 60331-2:2018.


Tests Carried Out

Test reports: “Shanghai Intelligent Service and Technology Co., Ltd,.". Report No.: TN24-7252E, TN25-5484E and TN19-0353, according to IEC 60092-350:2020; IEC 60092-360:2021, IEC 60092-376:2017; IEC 60331-1:2018, IEC 60331-2: 2018.

Inspection report (Date on 2025, January) witnessed and signed by RINA Surveyor. Filed by RINA with drawing SHEL-25859.

Reference Documents

Technical drawings and manuals approved and filed by RINA listed on Approval letter No.: SHEL/2025/902/ZHITA and SHEL/2025/1443/ZHITA.




ATTACHMENT TO
CERTIFICATE No. MED122524WS/002
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Qiang Sun
**** NOTICE: This is NOT an official certificate ****