Product Description150/250V shipboard control cables having following rating:
Type Designation | Number of
Pairs/Triples | Nominal Conductor
Cross-sectional Area
[mm2] | Maximum rated
Conductor Temperature [0C] | Fire Property |
CKJ85/86/95/96
CKJP85/86/95/96
CKJPJ85/95
CKJPF86/96
CKJPJP85/95
CKJPFP86/96
/(SC/NC) | 2~37 | Core two-wire group:0.75~2.5 | 90 | Fire-resisting
- IEC 60332-1
- IEC 60331-1
- IEC 60331-2 |
Note: + “Number of Core” is selected from the following series of core number:
2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37.
+“Nominal Conductor Cross-sectional Area” is selected from the following series of core number:
0.75, 1.0, 1.5, 2.5 mm2.
+ Conductor: Tinned copper conductors.
+ Other properties’ suffix:
CK: Shipboard control cable.
J : XLPE
P : Aluminum foil & tinned copper drain wire
XLPE: Cross-linked polyethylene
PJ : Thermoset polyolefin (SHF2).
PF: Thermoplastic polyolefin (SHF1).
8 : Tinned copper wire braided.
9 : Galvanized steel wire braided.
5 : Thermoset polyolefin (SHF2).
6 : Thermoplastic polyolefin (SHF1).
SC: Bunched Flame Retardant, Low Smoke, Halogen-Free
NSC: Low smoke, halogen free and low toxicity, fire resistance, flame retardant for bunched wires or cables.
 | ATTACHMENT TO
CERTIFICATE No. MED122524WS/002
Page 2 of 3 |
Application
The control and instrumentation cables are approved used for fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces in marine and offshore field.
Design Assessment
The design assessment is based on SOLAS 74 Reg. II-2/7, IMO Res. IMO Res. MSC.36(63)-(1994 HSC Code) 7, IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO Res. MSC.98(73)-(FSS Code) 9, IMO Res. MSC.391(95)-(IGF Code) 11, IMO MSC.1/Circ.1242.
Cable installation in ships, as applicable, comply with IEC standards: IEC 60092-504:2016, IEC 60533:2015. IEC 60092-376:2017, IEC 60331-1:2018 or IEC 60331-2:2018.
Tests Carried Out
Test reports: “Shanghai Intelligent Service and Technology Co., Ltd,.". Report No.: TN24-7252E, TN25-5484E and TN19-0353, according to IEC 60092-350:2020; IEC 60092-360:2021, IEC 60092-376:2017; IEC 60331-1:2018, IEC 60331-2: 2018.
Inspection report (Date on 2025, January) witnessed and signed by RINA Surveyor. Filed by RINA with drawing SHEL-25859.
Reference Documents
Technical drawings and manuals approved and filed by RINA listed on Approval letter No.: SHEL/2025/902/ZHITA and SHEL/2025/1443/ZHITA. |