ABN403C/ABS403C/ABH403C/ABL403C/ABN803C/ABS803C/ABL803C
Product Description
- Moulded case circuit breaker type METASOL applicable to the marine environment with following rating :
Type | Rated Freq.
[Hz] | Rated Current at 45℃
In[A] | Rated Oper. Volt.
Ue[V] | Service
Short-circuit Breaking Capacity Ics[kA] | Ultimate
Short-circuit
Breaking Capacity
Icu[kA] | Rated
Short-circuit
Making Capacity
Icm[kA] | Util.
Cate-gory |
ABN403c | 50/60 | 250
300
350
400 | 690
480/500
415/460
380
220/250 | Ics = Icu | 5
18
37
42
50 | 8
36
78
88
105 | A |
ABS403c | 50/60 | 250
300
350
400 | 690
480/500
415/460
380
220/250 | Ics = Icu | 8
35
50
65
75 | 14
74
105
143
165 | A |
ABH403c | 50/60 | 250
300
350
400 | 690
480/500
415/460
380
220/250 | Ics = Icu | 10
50
65
70
85 | 17
105
143
154
187 | A |
ABL403c | 50/60 | 250
300
350
400 | 690
480/500
415/460
380
220/250 | Ics = Icu x 75% | 14
65
85
100
125 | 28
143
187
220
275 | A |
ABN803c | 50/60 | 500
630
700
800 | 690
480/500
415/460
380
220/250 | Ics = Icu | 8
25
37
45
50 | 14
53
78
95
105 | A |
ABS803c | 50/60 | 500
630
700
800 | 690
480/500
415/460
380
220/250 | Ics = Icu | 10
45
65
75
85 | 17
95
143
165
187 | A |
ABL803c | 50/60 | 500
630
700
800 | 690
480/500
415/460
380
220/250 | Ics = Icu x 75% | 14
65
85
100
125 | 28
143
187
220
275 | A |
Reference Documents
DEKRA CB scheme Test Report No. 3306471.50 dated 21 July 2014, No. 3306471.51 dated 21 July 2014
No. 4789371920 dated 19 May 2020, No. 4789371921 dated 08 April 2020
UL IECEE cb scheme No. DK-95885-UL dated 08 April 2020, No. DK-96105-UL dated 08 April 2020
Environmental Test (including Vibration & Inclination Test): PT&T Report No. R411-0324,0325 dated 22 April 2011
Renewal Test (Visual Inspection & Function Test): PT&T Report No. R426-1073 dated 11 June 2026
Asbestos-free Declaration (SOLAS II-1/reg.3-5): LSIS letter dated 09 July 2026
Note/Remark
l The product is subject to the compliance with RINA Rules and other Standards mentioned on certificate.
l Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
l Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
l Each Circuit Breakers with nominal current greater than 100A are subject to Final Inspection/Final Test of the Society
l Validity of this Type Approval Certificate is subject to the maintenance of a Production Quality Assurance certificate by RINA, covering the production of the type approved products.
Renewal/Revision
l 17/05/2011: initial certification. Certificate No. ELE068811PU
l 31/12/2015: renewed without design change. New certificate No. ELE275815PU revokes previous certificate
l 30/12/2020: renewal certification without design change.
l 09/07/2026: renewed without design change. New certificate revokes previous certificate No. ELE148620PU