Bulkhead consisting of panels having maximum height of 2400 mm and maximum width of 600 mm. The panels are composed of a mineral wool layer fitted with glass veil type ISOVERD Ultimate U SeaProtect slab 100 V1, (certified non combustible in conformity to the requirements of the IMO FTP Code), 15 mm thick and having density of 100 kg/m3 glued, by means of 100 g/m2 of glue named PROTOPUR AE 100 or 140 g/m2 of glue type SikaForce-110 to a steel sheet having thickness of 0.7 mm. The mineral wool is covered with a layer of material coated with a glass cloth named FIREMASTER MARINE PLUS BLANKET GC, 19 mm thick and having density of 96 kg/m3. The bulkhead may be fitted, at the maximum height of 2130 mm, with metallic box, 35 mm deep and having maximum dimensions of 94x55 mm, composed of steel sheet having thickness of 0.6 mm. The box is insulated, on the outside, by means of the FIREMASTER MARINE PLUS BLANKET GC layer. The insulating materials are fixed by means of steel staples fitted with pitch of 350 mm. The panel joints consist of āLā shaped sheet bent edges, relevant locking and fixing by means of screws fitted with pitch of 350 mm. The joints are equipped with a layer of FIREMASTER MARINE PLUS BLANKET having thickness of 19 mm and are covered by means of a restore steel profile type 27CM14724, 0.5 mm thick, fixed by means of screws fitted with pitch of 350 mm. The panels are provided with horizontal stiffeners, 1.2 mm thick and having dimensions of 30x12 mm, glued with 150 g/m2 of EXTRABOND NO FIRE adhesive to the sheet with pitch of 600 mm. The bulkhead is fitted, on the perimeter, with U shaped steel containment profiles having dimensions of 35x50 mm and thickness of 2 mm provided of screws with pitch of 200 mm.Field of application Fire resistant B-15 Class bulkhead for general applications.
Reference documents Marine Interiors SpA drawing No. +24PC00277.01 Rev. 01 dated 12 December 2017 and Marine Interiors Cabins SpA drawing No. 24PC00347 Rev. 01 dated 22 October 2020, approved on 14 March 2018 and on 2 December 2020 respectively with endorsement No. LABS-1622 and No. LABS-2112.
Tests carried out Tests as per RINA Test Laboratory reports No. 2017CS013976 dated 14 March 2018 and No. 2020CS012817/6 dated 2 December 2020 issued according to IMO 2010 FTP Code Part 3. |