1. Product Description
0.6/1kV shipboard electric power cables with following rating:
Type
Designation | Rated
Volt. | Number of
Cores | Nominal Conductor
Cross-sectional
Area [㎟] | Maximum rated
Conductor
Temperature
[℃] |
CE85, CE95, CE86, CE96,
CEPJ, CEPJ80, CEPJ90, CEPJ85, CEPJ95, CEPJR
CEPF, CEPF80, CEPF90, CEPF86, CEPF96, CEPFR
CEPJP, CEPJP80, CEPJP85, CEPJP90, CEPJP95
CEPFP, CEPFP80, CEPFP86, CEPFP90, CEPFP96
(DC/SC/NSC/NC)
CE82, CE92
CEF, CEF80, CEF90, CEF82, CEF92, CEFR
CEH, CEH80, CEH90, CEH82, CEH92, CEHR
CEV, CEV80, CEV90, CEV82, CEV92, CEVR
CEFP, CEFP80, CEFP82, CEFP90, CEFP92, CEFPR
CEVP, CEVP80, CEVP82, CEVP90, CEVP92
CEHP, CEHP80, CEHP82, CEHP90, CEHP92
(DA/SA/NSA/NA) | 0.6/1kV
1.8/3kV | 1 ~ 5 core
6 cores
7 ~ 37 cores | 1.0 ~ 300 mm²
1.0 ~ 6 mm²
1.0, 1.5, 2.5 mm² | 90 |
CJ85, CJ95, CJ86, CJ96,
CJPJ, CJPJ80, CJPJ90, CJPJ85, CJPJ95, CJPJR, CJPF, CJPF80, CJPF90, CJPF86, CJPF96, CJPFR, CJPJP, CJPJP80, CJPJP85, CJPJP90, CJPJP95, CJPFP, CJPFP80, CJPFP86, CJPFP90, CJPFP96
(DC/SC/NSC/NC)
CJ82, CJ92, CJV, CJV80, CJV90, CJV82, CJV92,
CJVR, CJVP, CJVP80, CJVP82, CJVP90, CJVP92
(DA/SA/NSA/NA) | 0.6/1kV | 1 ~ 5 core
6 cores
7 ~ 37 cores
| 1.0 ~ 300 mm²
1.0 ~ 6 mm²
1.0, 1.5, 2.5 mm² |
| CBYJR DC/SC/NSC | 450/750 V | 1 cores | 0.75 ~ 240 mm² |
Note: +“Conductor Cross-section” is selected from the following series of conductor size:
0.75, 1.0, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm2
+“Number of Core” is selected from the following series of core number:
1, 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37
TYPE APPROVAL CERTIFICATE
NO. ELE503324WS/001
Enclosure - Page 2 of 2
+ Outer Protection:
80: Copper wire braided
90: Galvanized steel wire braided
82: Copper wire braided with PVC outer sheathed
92: Galvanized steel wire braided with PVC outer sheathed
85: Copper wire braided with cross-linked polyolefin outer sheathed
95: Galvanized steel wire braided with cross-linked polyolefin outer sheathed
86: Copper wire braided with thermoplastic polyolefin outer sheathed
96: Galvanized steel wire braided with thermoplastic polyolefin outer sheathed
+ Flammability Code:
DA: Single flame retardant cable, comply with IEC 60332-1
SA: Bunched flame retardant cable, comply with IEC 60332-3
NSA(NA): Fire resistant cable, comply with IEC60332-3, IEC60331
DC: Halogen-free Low-smoke Single flame retardant cable, comply with IEC 60332-1, IEC60754, IEC61034
SC: Halogen-free Low-smoke bunched flame retardant cable, comply with IEC 60332-3, IEC 60754, IEC61034
NSC(NC): Halogen-free Low-smoke fire resistant cable, comply with IEC 60332-3, IEC60331, IEC 60754, IEC 61034.
+ Other properties’ suffix:
C: Shipboard power cable
J : XLPE insulation
E : EPR insulation
V: PVC Inner Sheath
F: PCP Inner Sheath
R: Soft structure
P: Separated screen
PJ : Cross-link polyolefin sheath (SHF2)
PF : Thermoplastic polyolefin sheath (SHF1)
2. Reference Documents:
+ Specification of marine power cables. Filed by RINA with drawing No.SHEL-21677.
+ Test Report: “Shanghai Intelligent Service and Technology Co., Ltd” Report No.: TN24-3154E, TN24-3155E and TN24-3157E. Filed by RINA with drawing No. SHEL-21682, SHEL-21683 and SHEL 21685.
+ Routine test Report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-21686.
+ Narrative report signed by Surveyor. Filed by RINA with drawing No. SHEL-20180.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-21679.
3. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment. |
|