Sensors application:
VEGACAL62 - solids, non conductive liquids Probe: partly insulated rod / PTFE
VEGACAL63 - conductive liquids Probe: fully insulated rod / PE / PTFE
VEGACAL64 - adhesive, conductive liquids Probe: fully insulated rod / FEP
VEGACAL65 - solids, non conductive liquids Probe: partly insulated cable
VEGACAL66 - solids, liquids Probe: fully insulated cable / PTFE
Codes description:
VEGACAL 62/63/64/65/66 a M b c d e f g h
a = Approvals
X without Ex approval
C with approval ATEX II 1G or II 1/2 G, II 2G Ex ia IIC T6
D with approval ATEX II 1/2 G, 2G, Ex d ia IIC T6
(certificate TUVNORD 05 ATEX 2799 X for capacitive measuring probe type VEGACAL CL6*.D_**HD**
(certificate TUVNORD 05 ATEX 2808 X for capacitive measuring probe type VEGACAL CL6*.C_**P/F*)
b = Version /Temperature Range
for VEGACAL 62 /63
A Standard / -50... 150°C
B Standard / -50... 200°C
C with screening tube AISI 316L / -50... 150°C
D with screening tube AISI 316L / -50... 200°C
I with concentric tube AISI 316L/ -50... 150°C
J with concentric tube AISI 316L/ -50... 200°C
K Standard / -50...150°C, PEEK
E PE- Insulation / -40... 80°C
F PTFE-Insulation / -50...150°C
G PTFE-Insulation / -50...200°C
H PE-Insulation and concentric tube 316L / -40... 80°C
I PTFE-Insulation and concentric tube 316L/ -50... 150°C
J PTFE-Insulation and concentric tube 316L/ - 50... 200°C
for VEGACAL CL 64
R FEP-Insulation / -50... 150°C
TYPE APPROVAL CERTIFICATE
No. ELE 071726XG
Enclosure - Page 2 of 3 VEGACAL 62, VEGACAL 63, VEGACAL 64, VEGACAL 65, VEGACAL 66 for VEGACAL 65
K cable d= 6mm / AISI 316 with gravity weight / - 50...150 °C
Y cable d= 6mm / AISI 316 without weight -/ -50... 150°C
U cable d= 6mm / AISI 316 with screening tube and gravity weight / -50 ...150 °C
L cable d= 6 mm / AISI 316L with gravity weight / -50... 200°C
S cable d=8mm / Steel with gravity weight / -50...200°C
T cable d=8mm / with abrasion protection -50....150°C
Q cable d=8mm / Steel without weight / -50...150°C
O cable d=6mm / 316 without weight / -50 ...200°C
R cable d=8mm / Steel with abrasion protection without weight / -50...150°C
1 cable d=6mm / with screening tube without weight / -50...150°C
2 cable d=6mm / with screening tube without weight / -50...150°C
V cable d= 6 mm / with screening tube and gravity weight / -50...200°C
For VEGACAL 66
N PTFE-insulated steel cable d= 8mm with gravity weight / -50...150°C
3 cable PTFE- insulated with gravity weight and screening tube / -50 ...150°C
L PTFE-insulated with gravidity weight 100mm / -50...150°C
c = Process connection /Material
thread, others
d = Electronics
H 4...20 mA / HART (two-wire)
X for connection to a signal conditioning instrument
P Profibus PA (only in connection with metal housing)
e = Housing / Protection
K Plastic / IP66 / IP67
R Plastic / double chamber housing / IP66 / IP 67
A Aluminium / IP66 / IP 68 ( 0,2 bar )
3 Aluminium / IP66 / IP 68 ( 1 bar )
D Aluminium double chamber / IP66 / IP68 ( 0,2 bar )
4 Aluminium double chamber / IP66 / IP68 ( 1 bar )
Y Aluminium double chamber / IP66 / IP67 with M12x1 for DIS 61
V Stainless Steel 316L / IP66 / IP68 ( 0,2 bar )
5 Stainless Steel 316L / IP66 / IP68 ( 1 bar )
W Stainless Steel double chamber housing 316L /IP66 / IP68 (1bar)
f = Cable entry / Plug connection
M M20x1,5 / Without
N 1/2 NPT / Without
C M20x1,5 / M12x1 (Assignment A)
B M20x1,5 / M12x1 (Assignment B)
I M20x1.5 / nach DIN 43650 resp. ISO 4400
H M20x1,5 / Harting HAN 8 straight
W M20x1,5 / Harting HAN 8 bent
F M20x1,5 / Harting HAN 7 Straight
G M20x 1,5 / Harting HAN 7 bent
Z 1/2" NPT / 7/8" NPT
TYPE APPROVAL CERTIFICATENo. ELE071726XG
Enclosure - Page 3 of 3 VEGACAL 62, VEGACAL 63, VEGACAL 64, VEGACAL 65, VEGACAL 66
g = Indicating and adjustment module PLISCOM
X without
A mounted
F without lid with inspection window
K Built-in, with Bluetooth, magnetic pen operation
B laterally mounted
L laterally mounted, with Bluetooth, magnetic pen operation
g = additional equipment Level measurement - Capacitive - VEGACAL 62, 63, 64, 65,66 doc. n° 30138-EN-160930Operating Instructions VEGACAL 63 4... 20mA / Hart doc. n° 30027-EN-200929
Operating Instructions VEGACAL 63 Profibus PA doc. n° 30028-EN-200929
Operating Instructions VEGACAL 63 Connect. to Instruments doc. n° 30318-EN-200929
Operating Instructions VEGACAL 64 4... 20 mA / Hart doc. n° 30030-EN-200929
Operating Instructions VEGACAL 64 Profibus PA doc. n° 30031-EN-200929
Operating Instructions VEGACAL 64 Connect. to Instruments doc. n° 30319-EN-200929
Operating Instructions VEGACAL 65 4... 20mA / Hart doc. n° 30033-EN-200929
Operating Instructions VEGACAL 65 Profibus PA doc. n° 30034-EN-200929
Operating Instructions VEGACAL 65 Connect. to Instruments doc. n° 30320-EN-200929
Operating Instructions VEGACAL 66 4...20 mA / HART doc. n° 30036-EN-200929
Operating Instructions VEGACAL 66 Profibus PA doc. n° 30037-EN-200929
Operating Instructions VEGACAL 66 Connect to Instruments doc. n° 30321-EN-200929
Test reports:
Hanse Control - EMC reports n° 05-L-00686-01, 05-L-00687-01, 05-L-00689-01, 2001-0142201R01/02/03
Paconsult - Environmental reports n° 0779-05B
VEGA- Flame retardant report n° CAP62R1.9-F1-1
VEGA- Pressure resistance report n° 1.04 CAP62R-F2-2
VEGA - Degrees of protection report n° 1.03-CAL62P-F1-2, 1.03-CAL62P-F1-1
Aucoteam - Salt mist test report n° 2813 / 97, 3766 / 01
Paconsalt - Salt mist test report n° 08-2268
Remarks:
- Wireless data links are not to be used in Category III systems unless specifically considered by the Society on the basis of an engineering analysis carried out in accordance with International or National Standard acceptable to the Society.
- For wireless data communication equipment, tests during harbour and sea trials are to be conducted to demonstrate that radio-frequency transmission does not cause failure of any equipment and does not its self-fail as a result of electromagnetic interference during expected operating conditions, |
|