Emergency Escape Breathing Device (open-circuit compressed air breathing apparatus with a hood for escape) is designed with the following main characteristics:
Model | Maximum Working Pressure | Volume | Air Deposit | Service Time (min) | Weight (Kg) |
THDX-15 | 21 Mpa | 3 L | 630 L | ≥15 (35 L/min) | ≤ 7.5 |
Main Components
Components | Model | Manufactory |
Gas Cylinder | 3 L Cylinder | Jiangsu Jiuwei High Pressure Vessel Manufacture Co., Ltd *)
Or, Shenyang Zhongfu Kejin Pressure Vessels Co., Ltd **) |
Air Cylinder Valve | DSPRZ-1 | Jiangsu Yigu Security Technology Co., Ltd |
Hood | DXTSM | Jiangsu Yigu Security Technology Co., Ltd |
Note: *) Seamless Steel Cylinder **) Fully Wrapped Composite Cylinder
Field of Application
Emergency Escape Breathing Devices to be use only for escape according to Ch II-2/Reg13.3.4 of SOLAS '74 as amended and designed according to Fire Safety Code, Ch.3, Par.2.2.
Reference Documents
Technical Drawing, approved by RINA with No. SHFP-15976;
Operation, Installation and Servicing Manual, filed by RINA with No. SHFP-12161;
Technical Specification, approved by RINA with No. SHFP-12162;
Bill of Material, approved by RINA with No. SHFP-12163;
Nameplate, approved by RINA with No. SHFP-12169;
Gas Cylinder Certificate (3L) (Ref No.: 0036-023-16 Rev.0), filed by RINA with No.: SHFP-12174.
 | ATTACHMENT TO
CERTIFICATE No. MED722126WS/008
Page 2 of 3 |
er: always">&nbTest Carried Out
Test Report No. 2018038 issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances, and filed by RINA with No. SHFP-12158.
Remarks
The device is not intended for use in fire fighting fires, entering oxygen deficient voids or tanks, nor to be worn by fire-fighters.
Each device shall be properly marked according to EN 1146 (2005), Par. 8 with means of identification, working duration, European Standard EN 1146, serial number, shelf life with manufacturer date and the maximum pressure vessel pressure.
"For escape only" shall be applied on each device. All EEBD training units shall be clearly marked.
Inspection, maintenance, use, transportation and shelf life shall be in accordance with the manufacturer’s instruction.
The Emergency Escape Breathing Device can be equipped with different 3L Gas Cylinder which is type approved.
Note
This certificate annuls and replaces the certificate No. MED258523WS/005 due to Change EU Authorised Representative,