ATTACHMENT TO
|
CERTIFICATE No. MED377819CS/001
|
|
|
|
|
|
|
|
|
|
|
|
|
| Place of unit verification |
|
|
|
| ONBOARD SHIP GNV MAJESTIC IMO NO. 9015735,, |
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
| 21110/DBLAB/033 |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
PPVT-33759 approved on 8 July 2020 "21110QA54041B2-Rev B_GNV_MAJESTIC_ETMB" PPVT-33760 approved on 8 July 2020 "21110QA54042B2-Rev B_GNV_Majestic_OMM" PPVT-33762 approved on 8 July 2020 "21110QA54044B2-Rev B_GNV_Majestic_SECP" PPVT-33761 approved on 8 July 2020 "21110QA54043B2-Rev B_GNV_Majestic_Record Book"
- - - - - - - - - - - - - ECG System ECO-DeSOx consisting of the verified components listed in "21110 - GNV - TECHNICAL MANUAL SCHEME B (ETMB)" approved with RINA No. PPVT-33759. - - - - - - - - - - - - - Tests carried out: EGCS Statutory Survey Report, doc. No. MAC377819CS/001. RINA job. ID. RS/2019/CS/01/3778
|
Limitation on the acceptance or use of the
product
In scheme B, according to MEPC.259(68), compliance with emission requirements is demonstrated by
continuous exhaust gas monitoring.
EGCS acceptance and use to be within the terms and conditions of Para. 2 of PPVT-33762 approved on 13 July 2020 : “21110QA54044B2-Rev B_GNV_Majestic_SECP” .
Monitoring system is subject to periodic surveys by RINA according to MEPC.259(68).
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|