MED003225CS!001ENGD- -  -  N- NAVYCROSS MONOLATO/A60 Deck-Pipes Transit -N- S- S- -07/01/2025- Marine Equipment- - SN- S- - N-  - 852,534B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED003225CS/001- N-Jan 6, 2030852534
 
Form
  Marine Equipment(TO)
Certification N. MED003225CS/001 - (ENG)
Certificate date 07/01/2025
Type Protezione antincendio
Product Penetrations through "A" Class divisions: (b) pipe, duct, trunk, etc. penetrations
Item Nº MED/3.26b
USCG Category N° 164.138

Model or Denomin.
Items
NAVYCROSS MONOLATO/A60 Deck-Pipes Transit
Applicant MARINONI S.P.A.
Place of requester VIA TAGLIOLINI 26 B  %  16152 Genova (GE)  % ITALY
Tel. N.,Fax, Email 010 659 651, 010 659 65 60, marinoni@marinoni.it
Directive (EU) 2024/1975
Standards IMO Res. MSC.307(88)-(2010 FTP Code) as amended - IMO MSC.1/Circ. 1488
Reference Documents IMO MSC.1/Circ.1276,SOLAS 74 Reg.II-2/9, IMO Res. MSC.1/Circ.1655
Request 20/12/2024
Expire date 06/01/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
No. MED003225CS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.26b
USCG Category Nº 164.138
Description Penetrations through "A" Class divisions: (b) pipe, duct, trunk, etc. penetrations
Type NAVYCROSS MONOLATO/A60 Deck-Pipes Transit
Applicant MARINONI S.P.A.
VIA TAGLIOLINI 26 B,16152 Genova (GE),ITALY
Testing standards applied IMO Res. MSC.307(88)-(2010 FTP Code) as amended - IMO MSC.1/Circ. 1488
Regulations specified and reference documents IMO MSC.1/Circ.1276; SOLAS 74 Reg.II-2/9, IMO Res. MSC.1/Circ.1655
Issued in Genoa on
This Certificate is valid until
January 7, 2025
January 6, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
No.  MED003225CS/001
Page 1 of 3

Product description

Penetrations of metallic pipes having diameter ranging from 6 mm up to 108 mm installed in A-class decks. These transits are composed of an “omega” shaped perforated steel sheet frame, 0.9 mm thick, applied on the edges of the deck plating aperture. The frame is filled with mineral wool type Rockwool SEAROX SL 620 having density of 100 kg/m3 and thickness of 40 mm and is coated, on the unexposed side, by means of a layer of product, named NAVYCROSS (density of 600 kg/m3), applied with a thickness ranging from 20 up to 50 mm. The same product covers the pipes, on the unexposed side, with a thickness of 5 mm and for a length of 200 mm.
Field of application
Fire resistant A-60 metallic pipes penetrations through decks as follows:
  • Carbon steel - stainless steel - CUNI pipes having diameter ranging from 6 mm up to 108 mm
  • Copper pipes having diameter ranging from 6 mm up to 20 mm

Reference documents
Marinoni SpA drawings No. 13/19 dated 6 November 2019 and No. 14/19 dated 29 November 2019 approved on 18 November 2019 and on 19 December 2019 respectively with endorsement No. LABS-1932 and No. LABS-1958.
Tests carried out
Tests as per RINA Test Laboratory Reports No. 2019CS012762/3 and No. 2019CS012762/4 issued on 18 November 2019 and on 19 December 2019 according to Appendix 1 of IMO 2010 FTPC Part 3.




ATTACHMENT TO
No. MED003225CS/001
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****