Product Description
The JALTA Series are intended for installation onboard ships and other marine installation for the incineration of oil residue (sludge) or solid waste. The system also enables solid waste to be added to the incinerator when operating in oil residue (sludge) mode after the incinerator has warmed up. The solid waste is then burned with the assistance from the oil residue (sludge) burner when the heat from burning solid waste is insufficient.
The incinerators consist of one combustion with diesel oil burner and sludge burner, waste oil pump (mill pump), cooling blower and furnace air damper.
Solid waste is fed into the incinerator through a door system with interlocks. This enables the waste packages to be loaded through the outer door and fed into the incinerators through the inner door when the outer door is closed in cycles (i.e., continuous feeding).
Ash accumulates in the combustion chambers and may be removed from the incinerator periodically when the incinerator is cold through the ash door.
A flue gas fan is fitted in the exhaust duct or on the incinerator module to pull a negative pressure in the combustion chamber. Cooling air is pulled through a jacket around the incinerator from the compartment the incinerator is located.
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 2 of 9 |
Application
Model(*) | 220AFD | 320AFD | 530AFD |
Type of solid waste loading | Continuous feed | Continuous feed | Continuous feed |
Calorific capacity kW (kcal/h) | 256 (220,000) | 372 (320,000) | 616 (530,000) |
Solid waste (kg/h), or | 45 | 80 | 90 |
Oil residue (sludge) (kg/h) | 26 | 37 | 62 |
Model(*) | 730AFD | 1000AFD | 1300AFD |
Type of solid waste loading | Continuous feed | Continuous feed | Continuous feed |
Calorific capacity kW (kcal/h) | 849 (730,000) | 1162 (1,000,000) | 1499 (1,290,000) |
Solid waste (kg/h), or | 110 | 165 | 200 |
Oil residue (sludge) (kg/h) | 85 | 116 | 150 |
(*) The first number denotes the design capacity in x 1000 kcal/h and AFD means that the incinerator is fitted with an "Auto Feeding Door". E.g. 220AFD is a 220,000 kcal/h incinerator fitted with an auto feeding door.
Electrical and control components
The units are controlled through automation systems of a type tested and accepted by a nationally recognized testing agency, according to international standards. Critical components are listed in the table below:
Component Type | Component Name and Model (**) | Maker |
Programmable Logic Controller (PLC) | MICROLOGIX 1400 Series | Allen-Bradley |
| SIMATIC S7-1200 Series | Siemens |
Human Machine Interface (HMI) | PV Plus 700 Series | Allen-Bradley |
| Pro-face GP4401 Series | Schneider Electric |
Flame Detection Replay | HRE-4X | Hyundai Marine Machinery Co., Ltd. |
Flame detector | Flame detection photocell QRB Series | Siemens AG |
(** ) The system can be configured with either a Allen-Bradley PLC and HMI or a Siemens PLC and HMI.
Change to these components are to be approved by RINA. Documentation confirming the approval are to be kept together with the certificate, or the certificate is to be updated.
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 3 of 9 |
The software and firmware editions are listed in the table below:
Component | Software/Firmware Edition | Date |
Allen-Bradley MICROLOGIX 1400 Series | Software : RS LOGIX 500V8.XX
Firmware : 1.X | 2016 |
Siemens SIMATIC S7-1200 | Software : TIA POTAL V13.XX
Firmware : 10.X | 2016 |
Allen-Bradley PV Plus 700 Series (HMI) | Software : FT VIEW STUDIO V7.XX
Firmware : 10.X | 2016 |
Schneider Electric Pro-face GP4401 Series (HMI) | Software : GP-Pro EX V4.XX
Firem 4.X | 2016 |
Changes in the software which can alter the performance of the systems is to be approved by RINA. Note that testing of the system with the revised software may be required. Documentation confirming the approval (and any testing) are to be kept together with the certificate, or the certificate is to be updated.
Basic of acceptance
Capacity and emissions testing according to IMO Res.MEPC.244(66) Annex I were carried out on the JALTA 220AFD, JALTA 730AFD and JAL 1300AFD models and the results are given in the Appendices to this certificate.
Electrical and mechanical control devices have been assessed according to IMO Res.MEPC.244(66) 3.14.1.7 based on certificate according to internal standards accepted by a national recognized testing agency. The control pannels for the MAXI JALTA 220AFD, JALTA 730AFD and JAL 1300AF models were each subjected to a function testing and the final test reports are listed in the "Test Reports" section of this certificate.
Inclination requirements according to IMO Res.MEPC.244(66) Section 6.2 were assessed during the testing of the JALTA 220AFD, JALTA 730AFD and JAL 1300AF models.
Prototype tests according to IMO Res.MEPC.244(66) Section 7.1 were carried out on the JALTA 220AFD, JALTA 730AFD and JAL 1300AF model and the final report is listed in the "Test Reports" section of this certificate.
The series of incinerators with capacities from 256 kW to 1499 kW use the same basic design. Therefore, testing on the smallest (JALTA 220AFD) and largest model (JALTA 1300AFD) is considered sufficient to cover all models. An additional test for solid waste was conducted for the midsize model (JALTA 730AFD).
The testing described above for solid waste was done under the authority of Bureau Veritas who issued EU MED Module B certificate no. 20688/B0 EC. The testing described above for oil residue (sludge) for the other models was done under the authority of Korean Register on behalf of the Republic of Korea.
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 4 of 9 |
Technical Documentation
- Technical drawings and Manual, filed by RINA approved drawing no.PUMC-27822, 27823 & 27823 as outlined below.
Drawing no. | Revision | Date | Description/name | Model |
HOS-SK022003 ~ 7 | R4 | 2016.04.12. | Main specification | JALTA 220AFD |
HOS-SK032003 ~ 7 | R4 | 2016.04.12. | Main specification | JALTA 320AFD |
HOS-SK053003 ~ 7 | R4 | 2016.04.12. | Main specification | JALTA 530AFD |
HOS-SK073003 ~ 7 | R4 | 2016.04.12. | Main specification | JALTA 730AFD |
HOS-SK100003 ~ 7 | R4 | 2016.04.12. | Main specification | JALTA 1000AFD |
HOS-SK130003 ~ 7 | R4 | 2016.04.12. | Main specification | JALTA 1300AFD |
HOS-SK-JTASTD-001 | R2 | 2016.04.12. | List of control /Safety / Automation | All Model |
HOS-SK-JTASTD-002 | R2 | 2016.04.12. | Process diagram incinerator | All Model |
JALTA-PND0220001 | R4 | 2016.03.29. | Piping diagram | JALTA 220AFD |
JALTA-B0220100 | R4 | 2016.03.29. | Outline dimension drawing | JALTA 220AFD |
HOS-B0220100 | R4 | 2016.03.29. | Assembly drawing of Basis part | JALTA 220AFD |
HOS-0220310 ~ 12 | R4 | 2016.03.29. | Assembly drawing of Refractory Lining | JALTA 220AFD |
JALTA-PND0320001 | R4 | 2016.03.29. | Piping diagram | JALTA 320AFD |
JALTA-B0320100 | R4 | 2016.03.29. | Outline dimension drawing | JALTA 320AFD |
HOS-B0320100 | R4 | 2016.03.29. | Assembly drawing of Basis part | JALTA 320AFD |
HOS-0320310 ~ 12 | R4 | 2016.03.29. | Assembly drawing of Refractory Lining | JALTA 320AFD |
JALTA-PND0530001 | R4 | 2016.03.29. | Piping diagram | JALTA 530AFD |
JALTA-B0530100 | R4 | 2016.03.29. | Outline dimension drawing | JALTA 530AFD |
HOS-B0530100 | R4 | 2016.03.29. | Assembly drawing of Basis part | JALTA 530AFD |
HOS-0530310 ~ 12 | R4 | 2016.03.29. | Assembly drawing of Refractory Lining | JALTA 530AFD |
JALTA-PND0730001 | R4 | 2016.03.29. | Piping diagram | JALTA 730AFD |
JALTA-B0730100 | R4 | 2016.03.29. | Outline dimension drawing | JALTA 730AFD |
HOS-B0730100 | R4 | 2016.03.29. | Assembly drawing of Basis part | JALTA 730AFD |
HOS-0730310 ~ 12 | R4 | 2016.03.29. | Assembly drawing of Refractory Lining | JALTA 730AFD |
JALTA-PND1000001 | R4 | 2016.03.29. | Piping diagram | JALTA 1000AFD |
JALTA-B1000100 | R4 | 2016.03.29. | Outline dimension drawing | JALTA 1000AFD |
HOS-B1000100 | R4 | 2016.03.29. | Assembly drawing of Basis part | JALTA 1000AFD |
HOS-1000310 ~ 12 | R4 | 2016.03.29. | Assembly drawing of Refractory Lining | JALTA 1000AFD |
JALTA-PND1300001 | R4 | 2016.03.29. | Piping diagram | JALTA 1300AFD |
JALTA-B1300100 | R4 | 2016.03.29. | Outline dimension drawing | JALTA 1300AFD |
HOS-B1300100 | R4 | 2016.03.29. | Assembly drawing of Basis part | JALTA 1300AFD |
HOS-1300310 ~ 12 | R4 | 2016.03.29. | Assembly drawing of Refractory Lining | JALTA 1300AFD |
| HOS-AFD130010 | R4 | 2016.03.29. | Assembly drawing of Auto feeding door | All Model |
| HMM-CB0220001 | R0 | 2007.10.01. | Outline of cooling blower | JALTA 220AFD |
| HMM-CB0320001 | R0 | 2008.01.01. | Outline of cooling blower | JALTA 320AFD |
| HMM-CB0530001 | R0 | 2008.01.01. | Outline of cooling blower | JALTA 530AFD |
| HMM-CB0730001 | R0 | 2008.01.01. | Outline of cooling blower | JALTA 1000AFD |
| HMM-CB1300001 | R0 | 2008.01.01. | Outline of cooling blower | JALTA 1300AFD |
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 5 of 9 |
Drawing no. | Revision | Date | Description/name | Model |
JALTA-CPTYAP002 ~ 4 | R3 | 2014.04.04. | ELECTRIC PANEL-LAYOUT/FRONT | All Model |
JALTA-CPTYAP006 ~ 8 | R3 | 2014.04.04. | ELECTRIC PANEL-MAIN CURRENT | All Model |
JALTA-CPTYAP015 ~ 24 | R3 | 2014.04.04. | ELECTRIC PANEL-CIRCUIT DIAGRAM | All Model |
JALTA-CPTYAP025 | R3 | 2014.04.04 | ELECTRIC PANEL-CIRCUIT OPTION | All Model |
JALTA-CPTYAP030 | R3 | 2014.04.04. | ELECTRIC PANEL-EXTERNAL SIGNAL | All Model |
JALTA-CPTYAP040 ~ 43 | R3 | 2014.04.04. | ELECTRIC PANEL-PART LIST | All Model |
JALTA-CPTYAP501 ~ 3 | R3 | 2014.04.04. | ELECTRIC PANEL-TERMINAL STRIP | All Model |
HNP-JALINC-EPA7 | R7 | 2011.11.26. | MAIN NAME PLATE | All Model |
NP-SIMENS-OPAPLC-JAL | R7 | 2014.09.11. | OPERATION INSTRUCTION PLATE | All Model |
NP-WNPLC | R9 | 2014.09.11 | WARNING PLATE | All Model |
HINC-PGM-MAXIJAL | R0 | 2015.09.11. | PLC LADDER SYSTEM SOFTWARE QUALITY PLAN | All Model |
V03-JALTA(PLC_SIMENS) | R3 | 2015.06.03. | INSTRUCTION MANUAL (NG25 ~ NG150) | All Model |
Capacity and Emission tests, and safety and control tests:
- Type Approval Test Procedure & Report for Shipboard Incinerator JALTA 220AFD, Hyundai Marine Machinery Co., Ltd. document no.MEDHD-ST-11-R0, Type Test Report No.HTTR-SO500201RD, dated 4 November 2008. (Witnessed by Bureau Verties)
- Type Approval Test Procedure & Report for Shipboard Incinerator JALTA 730AFD, Hyundai Marine Machinery Co., Ltd. document no.MEDHD-ST-11-R0, Type Test Report No.HTTR-SO500101RD, dated 4 November 2008. (Witnessed by Bureau Verties)
- Type Approval Test Procedure & Report for Shipboard Incinerator JALTA 1300AFD, Hyundai Marine Machinery Co., Ltd. document no.MEDHD-ST-11-R0, Type Test Report No.HTTR-SO500301RD, dated 4 November 2008. (Witnessed by Bureau Verties)
- Shipboard Incinerator Final Test Report JALTA 220AFD, Hyundai Marine Machinery Co., Ltd., Test Report No.HFT-SO500201, dated 30 January 2008. (Witnessed by Korean Register on behalf of the Republic of Korea.)
- Shipboard Incinerator Final Test Report JALTA 1300AFD, Hyundai Marine Machinery Co., Ltd., Test Report No.HFT-SO500301, dated 15 January 2008. (Witnessed by Korean Register on behalf of the Republic of Korea.)
- Test reports, filled by RINA approved drawing no.PUMC-27825.
Marking of product
For traceability to this type approval, each incinerator is to be marked with:
- Manufacturer's name or trade mark
- Style, type, model or other manufacturer's designation for the incinerator (i.e., model name with serial number)
- Capacity (net design heat release)
Note
- This certificate annuls and replaces the certificate No. MED247025PU dated 01-04-2026 due to change of the applicant's address.
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 6 of 9 |
Appendix - Tests on JALTA 220AFD
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | JALTA 220AFD |
Place and date of tests | Seoul, 29 September 2008 (solid waste, witnessed by Bureau Veritas)
Seoul, 30 January 2008 (oil residue, witnessed by Korean Register on behalf of the Republic of Korea) |
Max. capacity | 302 kW (with Oil Residue (sludge))
153 kW (with Solid Waste) |
Oil Residue (sludge) | 31.2 l/h
37,080 KJ/kg (15% water content) |
Solid Waste | 46.6 kg/h IMO Class 2
11,793 kJ/kg |
Pilot Fuel Consumption (Oil Residue (sludge)) | 0 kg/h per burner |
Pilot Fuel Consumption (Solid Waste) | 10 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste | Oil Residue (sludge) |
O2 average in combustion chamber / zone | 11.2 % | 11.3 % |
CO average in flue gas | 28.5 mg/MJ | 23.2 mg/MJ |
Soot number average | Bacharach 0 | Bacharach 0 |
Combustion chamber flue gas outlet temperature average | 950 °C | 950 °C |
Amount of unburned components in ashes | 6.8 % | 0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste | Oil Residue (sludge) |
Temperature | 295 °C | 292 °C |
Distance | 2.5 m | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 7 of 9 |
Appendix - Tests on JALTA 730AFD
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | JALTA 730AFD |
Place and date of tests | Seoul, 30 September2008 (witnessed by Bureau Veritas) |
Max. capacity | 340 kW (with Solid Waste) |
Solid Waste | 113.9 kg/h IMO Class 2
11,799 KJ/kg |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner (2 burners) |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste |
O2 average in combustion chamber / zone | 11.5 % |
CO average in flue gas | 17.14 mg/MJ |
Soot number average | Bacharach 0 |
Combustion chamber flue gas outlet temperature average | 951 °C |
Amount of unburned components in ashes | 7.0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste |
Temperature | 308 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193826PU
Page 8 of 9 |
Appendix - Tests on JALTA 1300AFD
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | JALTA 1300AFD |
Place and date of tests | Seoul, 1 October 2008 (witnessed by Bureau Veritas)
Seoul, 15 January 2008 (oil residue, witnessed by Korean Register on behalf of the Republic of Korea) |
Max. capacity | 1536 kW (with Oil Residue (sludge))
679 kW (with Solid Waste) |
Oil Residue (sludge) | 170.9 l/h
34,370 KJ/kg (16% water content) |
Solid Waste | 207.0 kg/h IMO Class 2
11,804 kJ/kg |
Pilot Fuel Consumption (Oil Residue (sludge)) | 0 kg/h per burner |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste | Oil Residue (sludge) |
O2 average in combustion chamber / zone | 10.72 % | 11.4 % |
CO average in flue gas | 0.88 mg/MJ | 32.1 mg/MJ |
Soot number average | Bacharach 0 | Bacharach 0 |
Combustion chamber flue gas outlet temperature average | 950 °C | 949 °C |
Amount of unburned components in ashes | 8.2 % | 0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste | Oil Residue (sludge) |
Temperature | 299 °C | 308 °C |
Distance | 2.5 m | 2.5 m |