Model of light: WS97 -12V50W / 12V80W manual off / manual on.
The above light is manufactured with following characteristics:
- Dimensions: 125 mm × 125 mm × 148 mm
- Constructional material: Body made of Chloroprene Rubber
- Lamp Type: Xenon Lamp (white, power: 50W/80W)
- Dimension of lamp support: 110 mm x 60 mm
- Power Supply: The search light is provided with power connected to the lifeboat / rescue boat battery (12 Volts)
- Minimum luminous intensity: 2500 cd
- Vertical and Horizontal Beam Angle: 6º
- Operation Time: ≥ 3 H
- Weight: 900 g
Tests Carried Out
Evaluation and Test Report (Ref. No.: A17-002-ZC-03) issued by Shanghai Inspection and Testing Institute of Instruments and Automation Systems Co., Ltd. dated on Feb.17 2017, and filed with RINA No. SHFP-24931;
Evaluation and Test Report (Ref. No.: A20-017-ZC-03) issued by Shanghai Inspection and Testing Institute of Instruments and Automation Systems Co., Ltd. dated on Mar.03 2021 in accordance with LSA Code, IMO Res. MSC.81(70) as amended and IEC 60945:2002 incl. IEC 60945 Corr. 1:2008, with test reports (Ref. No.: W0211225003, W0211225004, W0211225006, W0211225007) issued by Shanghai Institute of Quality Inspection and Technical Research & China National Lighting Fitting Quality Supervision Testing Centre, and filed with RINA No. SHFP-24932, together with the test outline prepared by Shanghai Yuqin Institute of Photo-electronic Technology, and filied by RINA with No.: SHFP-24923;
Routine Test Report carried out and filed by RINA with No.: SHFP-34441.
 | ATTACHMENT TO
CERTIFICATE No. MED774625WS/001
Page 2 of 3 |
Reference Documents
Technical drawings and manuals edited by Shanghai Yuqin Optoelectronic Technology Co., Ltd:
- Bill of Material approved by RINA with No.: SHFP-5105;
- Technical specification approved by RINA with No.: SHFP-5106;
- Instruction manual filed by RINA with No.: SHFP-5050;
- Booklet of technical drawings approved by RINA with No.: SHFP-5051.
Field of Application
For use on board lifeboats and rescue boats.
Remark
Searchlights shall be clearly marked with approval information, date of expiry and illuminant voltage and power consumption according to LSA Code requirements.
Notes
The certificate was issued considering testing standard adopted by IMO Resolution MSC.323(89) (IEC 60945:2002 incl. IEC 60945 Corr. 1:2008, IEC 60447:2004).
This certificate annuls and replaces the certificate No. MED447923WS dated 10/24/2023 due to request by client to change the company information.