ATTACHMENT TO
|
CERTIFICATE Nr. MED351415CS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
15-038-APC-SC-100 DG3 Intended for ship COSTA PACIFICA |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
PRMT-12401 approved on 20 November 2015 : “COSTA PACIFICA DG#3 PUMPS” - 15-038-APC-PID-0PM-R01 PRMT-12402 approved on 20 November 2015 : “COSTA PACIFICA DG#3 - DG#3 SCRUBBER” - 15-038-APC-PID-3SC-R01
PRMT-12405 approved on 20 November 2015 : “Exhaust Gas Cleaning System – Onboard Monitoring Manual” – 15-038-APC-OMM Rev.28thOctober2015
PRMT-12404 approved on 20 November 2015 : “Exhaust Gas Cleaning System – Technical Manual – Scheme B” – 15-038-APC-ETM-B Rev.28thOctober2015
PRMT-12406 approved on 20 November 2015 : “SOx Emissions Compliance Plan” – 15-038-APC-SECP Rev.28thOctober2015
- - - - - - - - - - - - -
ECG System ECO-DeSOx consisting of the following verified components:
EGC tower (ECOSPRAY TECHNOLOGIES / ECO-DeSOx / 15-038-APC-SC-100 DG3) Sprayer nozzles (PNR / AAU2780L61 / AAU3194N6SG) SW Pump (POMPE GARBARINO / MU200-315L) SW Pump Motor (ABB / M3BP 315MLA4) Dilution Pump (POMPE GARBARINO / MU250-250LDS) Dilution Pump Motor (ABB / M3BP 280SMB6) Automatic Self-Cleaning SW Filter (Filtrex / ACB-955-300) Static Mixer (ECOSPRAY TECHNOLOGIES / SM01-300/400) PAH Sensors (Hach Lange / FP 360 sc) pH Sensors (Hach Lange / pHD sc Digital Differential pH) Turbidity Sensors (Hach Lange / Ultraturb sc) Free O2 Sensor (Hach Lange / LDO Sensor) Conductivity Sensor (Hach Lange / 3700 sc) Gas Analyzer (Kittiwake Procal Ltd. / PROCAL 2000) SW Pump Inverter (Danfoss / FC-102N200T4E54H2TGR3) Dilution Pump Inverter (Danfoss / FC- 102P55KT4P55H5TGC1) PLC Panel (ECOSPRAY TECHNOLOGIES / Main Panel 01) VDU Touchscreen 10” (SIEMENS / 6AV6643-0CD01-1AX1) - - - - - - - - - - Tests carried out:
EGCS Statutory Survey Report, doc. No. 2015CS013514. RINA job. ID. RS/2015/CS/01/3515 and RS/2015/CS/01/872 and RS/2015/CS/01/3514
|
Limitation on the acceptance or use of the
product
In scheme B, according to MEPC.259(68), compliance with emission requirements is demonstrated by continuous exhaust gas monitoring.
EGCS acceptance and use to be within the terms and conditions of “Procedure for Compliance” at Para. 6 of PRMT-12406 approved on 5th November 2015 : “SOx Emissions Compliance Plan” – 15-038-APC-SECP.
Monitoring system is subject to periodic surveys by RINA according to MEPC.259(68).
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|