Reference documents
Evac CSWE Series(4~400) Sewage treatment plants manufactured according to the Shanghai Shijiu Marine
Equipment CO., LTD technical specification and Drawings with RINA Approved No. SHMC-12304~12307 and
SHMC-21743~21747.
Influent/effluent samples Testing Report No.:SQJC-HJ-20172986,SQJC-HJ-20173031 carried out by Shanghai Light Industry Environmental Protect and Pressure Vessel Monitoring General Station dated 29/12/2017.
Influent/effluent samples Testing Report No.:HJ22000758 carried out by Ningbo Customs District Technology
Center dated 08/08/2022.
Environmental Testing Reports carried out by Marine Environment Engineering and Reliability Laborator of NO.704 Research Institute of CSIC dated 30/03/2016 as followings(No.): -S118-GW-2016, S118-DW-2016, S118-SR-2016, S118-ZD-2016, S118-QY-2016.
Type approval test program prepared by manufacturer and reviewed with RINA No.SHMC-12302 and
SHMC-21740.
Technical characteristics
Evac CSWE series(4~400) sewage treatment plants are designed for biological operation based on an aerobic process.
Model:CSWE Series | Capacity(m3/day) | Organic load(kg/day) |
Evac CSWE-4 | 0.28 | 0.14 |
Evac CSWE-8 | 0.56 | 0.28 |
Evac CSWE-12 | 0.84 | 0.42 |
Evac CSWE-20 | 1.4 | 0.7 |
Evac CSWE-30 | 2.1 | 1.05 |
Evac CSWE-40 | 2.8 | 1.4 |
Evac CSWE-60 | 4.2 | 2.1 |
Evac CSWE-80 | 5.6 | 2.8 |
Evac CSWE-120 | 8.4 | 4.2 |
Evac CSWE-160 | 11.2 | 5.6 |
Evac CSWE-200 | 14 | 7.0 |
Evac CSWE-300 | 21 | 10.5 |
Evac CSWE-400 | 28 | 14 |
 | ATTACHMENT TO
CERTIFICATE No. MED193322WS/002
Page 2 of 5 |
Type of disinfectant used:Ultraviolet.
Discharge standard within the following limits:
| Thermotolerant Coliforms (geometric mean) | Less than 100 cells/100ml |
| 5-day Biochemical Oxygen Demand(BOD5) | Less than 25 mg/l |
| Chemical Oxygen Demand (COD) | Less than 125 mg/l |
| Total Suspended Solids (TSS) | Less than 35mg/l |
| PH value | Between 6.0 and 8.5 |
Fields of application
Each sewage treatment plant is to be supplied with it's manual for installation, use and maintenance.
The installation on board is to be carried out in accordance with manufacturer's instructions.
A copy of this EC type-examination certificate shall be carried on board any ship, equipped with the above
discribed sewage treatment plant at all times.
Limitations and conditions of operation are imposed as follows: Inclination less than 22.5 degrees and
Viabration 2 to 13.2Hz with an amplitude of plus or minus 1mm and 13.2 to 80 Hz with an acceleration of plus
or minus 0.7g.
The requirements stipulated in Sec 4.2 of IMO Resolution MEPC.227(64) does not apply to Evac CSWE Series sewage treatment plant.
Marking of product
A plate or durable label shall be placed on the sewage treatment plant with at least the following information:
-Manufacturer's name or logo
-Model and serial number
-Hydraulic loading
Note
This certificate annuls and replaces the previous certificate No. MED061122WS.
 | ATTACHMENT TO
CERTIFICATE No. MED193322WS/002
Page 3 of 5 |
APPENDIX TO CERTIFICATE OF TYPE APPROVAL FOR SEWAGE TREATMENT PLANTS
Test results and details of tests conducted on samples from the sewage treatment plant in accordance with resolution MEPC.227(64),as amended(exception for section 4.2):
Sewage treatment plant, Type ..................................................................................................CSWE-8
Manufactured by .......................................................................Shanghai Shijiu Marine Equipment Co.,Ltd
Organization conducting the test .............................................Shanghai Light Industry Environmental Protect and Pressure Vessel Monitoring General Station
Designed hydraulic loading .........................................0.56........................... .....m3/day
Designed organic loading ............................................0.28...................... kg/day BOD
Number of effluent samples tested ....................................48.....................................
Number of influent samples tested ....................................48....................................
Total suspended solids influent quality ............. ................>500............................... mg/l
BOD5 without nitrification influent quality ...........................>500............................... mg/l
Maximum hydraulic loading ..............................................0.56............................... m3/day
Minimum hydraulic loading ...............................................0.56.............................. m3/day
Average hydraulic loading (Qi) ...........................................0.56.............................. m3/day
Effluent flow (Qe)..............................................................0.56.............................. m³/day
Dilution compensation factor (Qi/Qe)…………………………...1…………………………….
Geometric mean of total suspended solids .........................14.81.............................mg/l
Geometric mean of the thermotolerant coliform count...................0........... ..coliforms/100 ml
Geometric mean of BOD5 without nitrification ......................22.69.............................. mg/l
Geometric mean of COD …………………………………........96.63………………….…….mg/l
Maximum pH: ………………………………………………….....7.81……….…………………
Minimum pH:………………………………………………………6.62…..………………..
Type of disinfectant used ...................................................UV Light.................................
If Chlorine - residual Chlorine:
Maximum .................................................../............................................ mg/l
Minimum ...................................................../................................... ........mg/l
Geometric Mean ........................................../........................................... mg/l
..
| ATTACHMENT TO
CERTIFICATE No. MED193322WS/002
Page 4 of 5 |
Was the sewage treatment plant tested with:
Fresh water flushing? .............................................................. Yes/No*
Salt water flushing? ................................................................. Yes/No*
Fresh and salt water flushing? ................................................ Yes
Grey water added? .................................................................Yes – proportion:7:11
Was the sewage treatment plant tested against the environmental conditions specified in section 5.9 of resolution MEPC.227(64):
Temperature ...............................................................................Yes
Humidity ................................................................................... Yes
Inclination ................................................................................. Yes
Vibration ................................................................................... Yes
Reliability of Electrical and Electronic Equipment ...........................Yes
Limitations and the conditions of operation are imposed:
Salinity .....................................................................................<35g/L
Temperature ......................................................................as per Part 3,MEPC.107(49)
Humidity ...........................................................................as per Part 3,MEPC.107(49)
Inclination .........................................................................as per Part 3,MEPC.107(49)
Vibration ...........................................................................as per Part 3,MEPC.107(49)
Results of other parameters tested ............................../..........................................