MED180925CSENG- -  -  N- SLIDING DOOR A60 SINGLE LEAF -N- S- S- -27/06/2025- Marine Equipment- - SN- S- - N-  - 244,549B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED180925CS- N-Nov 27, 2028244549
 
Form
  Marine Equipment(TO)
Certification N. MED180925CS - (ENG)
Certificate date 27/06/2025
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
SLIDING DOOR A60 SINGLE LEAF
Applicant NAVAL SUPPLIERS SRL Unipersonale
Place of requester ZONA INDUSTRIALE 24  %  33049 San Pietro Al Natisone (UD)  % ITALY
Tel. N.,Fax, Email +39 0432 727860, +39 0432 727886, firedoors@navalsuppliers.com
Directive (EU) 2024/1975
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ. 1319
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Request 27/06/2025
Expire date 27/11/2028
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED180925CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type SLIDING DOOR A60 SINGLE LEAF
Applicant NAVAL SUPPLIERS SRL Unipersonale
ZONA INDUSTRIALE 24,33049 San Pietro Al Natisone (UD),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ. 1319
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Issued in Genoa on
This Certificate is valid until
June 27, 2025
November 27, 2028
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED180925CS
Page 1 of 3

Product description

Single leaf sliding door with maximum frame clear light of 3000x3500 mm (WxH). The leaf, having maximum dimensions of 3085x3540 mm (WxH) is composed of two steel sheets, 1.2 mm thick each and, in between, the insulating material composed of one layer of product named KNAUF PBE FIRE BOARD M18V, 50 mm thick and having density of 180 kg/m3 and one layer of material type PROMAGLAF GM having thickness of 12.6 mm and density of 165 kg/m3. The insulating materials are glued together and to the steel sheets by means of 250 g/m2 of adhesive type DUNA CORRADINI AD1670V1+3200. The leaf is fitted, inside, with C shaped steel stiffeners, 1.2 mm thick and having dimensions of 60x20 mm tack welded (pitch of 250 mm) symmetrically to the two steel sheets with pitch of 500 mm. The steel sheets are fitted on both side of the leaf, with butt joints, with a steel backing flat, in the inside, 1.2 mm thick and having width of 60 mm, fixed by means of spot welding. Inside the leaf is fitted, on the upper side and on the vertical side opposite to the lock, with an U shaped steel profile, 6 mm thick and having dimensions of 60x30 mm, and, outside, with a C shaped steel profile having thickness of 1.2 mm and dimensions of 67.4x15 mm. The door frame is composed of steel profiles having thickness of 5 mm. The door may be fitted with a self-closing hose port having maximum dimensions of 160x188 mm.
Doors having frame clear light of more than 2410x2400 mm (WxH) (tested size) are required to have four suspensions trolleys and an extension of 20 mm of the vertical guide at the door tail (side opposite to the lock).
Field of application
Fire resistant A-60 Class single leaf sliding door with the fire hazard on both sides.
For doors exceeding 50% in surface area with respect to the tested doors, the installation on board has to be submitted, on a case-by-case basis, also to a full analysis based on Solas Regulation II-2/17 (alternative design).

In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested;
- door used with a fire tested frame design.

The surfaces of this division may be fitted with products having low flame spread characteristics, installed as described in the relevant type approval certificates and satisfying the requirements of SOLAS 74 Reg. II-2 as applicable.





 



ATTACHMENT TO
CERTIFICATE Nr. MED180925CS
Page 2 of 3



Reference documents
Naval Suppliers drawings:
  • No. FT-SLA61-2424LC18-R0 Rev. 1 dated 10 July 2018 approved on 17 July 2018 with endorsement No. LABS-1674 (tested configuration);
  • No. FT-SLA61-242417-R0 Rev. 1 dated 18 July 2018 approved on 20 July 2018 with endorsement No. LABS-1678 (tested configuration);
  • No. FT-SLA61-242417-RINF Rev. 0 dated 7 November 2018 and approved on 8 November 2018 with endorsement No. LABS-1754;
  • No. FT-SLA61-3000x3500 Rev. 01 dated 26 June 2025 enclosed to the job No. 2025CS011809 (enlarged configuration).

Tests carried out
Tests as per RINA Test Laboratory reports:
  • No. 2017CS012892/1 dated 18 December 2017;
  • No. 2018CS011535/2 dated 17 July 2018;
  • No. 2018CS012701/1 and No. 2018CS012701/2 dated 8 November 2018,

issued according to IMO 2010 FTP Code Part 3.

Increased dimensions verified with Technical Report No. 2025-01-MITHP dated June 2025.






ATTACHMENT TO
CERTIFICATE No. MED180925CS
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****