Bulkhead consisting of panels having, maximum height of 2400 mm and maximum width of 1240 mm. Such panels are composed of one steel sheet, 2 mm thick, and one layer of mineral wool with aluminium foil Rockwool type SeaRox MA 740 ALU, having thickness of 30 mm and density of 45 kg/m3, fixed to the steel sheet by means of pins and washers welded with pitch ranging from 335 up to 360 mm. The panel joints consist of “L” shaped bent edges of the steel sheets, insertion of a “U” shaped steel vertical profile, 2 mm thick and having dimensions of 89x55 mm. The “U” profiles are filled with No. 2 layers of the same mineral wool and the joints are covered, on the side opposite to the steel sheets, with a further layer of mineral wool having width of 350 mm fixed to the steel sheet by means of N. 3 pins and washers welded with pitch of 122 mm in horizontal (one on the middle of the vertical mullion and the others, one on each panel) and with a pitch of 360 mm in vertical; this additional layer covers also all the bulkhead edges for a width of 300 mm. The panel steel sheets and the “U” shaped profiles are fixed on the upper and lower sides, to steel flats, 5 mm thick and having width, respectively, of 160 and 130 mm, by means of M8 screws having a ranging pitch from 122 mm (in way of the vertical mullions) up to 500 mm (in way of the panels). The joints are fitted with polyethylene spacer UNITEC type PLASTAZOTE, having dimensions 15x4 mm and 15x20 mm, and are sealed with SIKA type SIKAFLEX 591. The central panel may be provided with a vertical insulation joint created by overlapping the two adjacent layers of insulation with a width of 150 mm. The bulkhead panels may be installed with the following mechanical fastening systems: N.1 M8 stainless steel screw “HILTI”, N.1 stainless steel screw D 6.3 mm, N.1 stainless steel screw D 5.5 mm, N.1 stainless steel screw D 4.8 mm, N.1 stainless steel screw D 4.2 mm, N.1 stainless steel threaded insert M8 with screw and N.1 stainless steel threaded insert M6 with screw.
Field of application Fire resistant A-0 Class lightweight bulkhead with fire hazard on side fitted with the mineral wool.
Reference documents SOMEC drawing No. TED-0017 dated 7 March 2024 enclosed to the Test Report No. 2024CS01521 issued on 27 May 2024.
Tests carried out Tests as per RINA Test Laboratory Report No. 2024CS01521 issued on 27 May 2024 according to IMO 2010 FTP Code Part 3. |